A modern day light microscope has evolved from a tool devoted to making primarily empirical observations to what is now a sophisticated, quantitative device that is an integral part of both physical and life science research. Nowadays, microscopes are found in nearly every experimental laboratory. However, despite their prevalent use in capturing and quantifying scientific phenomena, neither a thorough understanding of the principles underlying quantitative imaging techniques nor appropriate knowledge of how to calibrate, operate and maintain microscopes can be taken for granted. This is clearly demonstrated by the well-documented and widespread difficulties that are routinely encountered in evaluating acquired data and reproducing scientific experiments. Indeed, studies have shown that more than 70% of researchers have tried and failed to repeat another scientist’s experiments, while more than half have even failed to reproduce their own experiments1. One factor behind the reproducibility crisis of experiments published in scientific journals is the frequent underreporting of imaging methods caused by a lack of awareness and/or a lack of knowledge of the applied technique2,3. Whereas quality control procedures for some methods used in biomedical research, such as genomics (e.g., DNA sequencing, RNA-seq) or cytometry, have been introduced (e.g. ENCODE4), this issue has not been tackled for optical microscopy instrumentation and images. Although many calibration standards and protocols have been published, there is a lack of awareness and agreement on common Standards and guidelines for quality assessment and reproducibility5.
In April 2020, the QUality Assessment and REProducibility for instruments and images in Light Microscopy (QUAREP-LiMi) initiative6 was formed. This initiative comprises imaging scientists from academia and industry who share a common interest in achieving a better understanding of the performance and limitations of microscopes and improved quality control (QC) in light microscopy. The ultimate goal of the QUAREP-LiMi initiative is to establish a set of common QC standards, guidelines, metadata models7,8, and tools9,10, including detailed protocols, with the ultimate aim of improving reproducible advances in scientific research.
This White Paper 1) summarizes the major obstacles identified in the field that motivated the launch of the QUAREP-LiMi initiative; 2) identifies the urgent need to address these obstacles in a grassroots manner, through a community of Stakeholders including, researchers, imaging scientists11, bioimage analysts, bioimage informatics developers, corporate partners, Funding agencies, standards organizations, scientific publishers, and observers of such; 3) outlines the current actions of the QUAREPLiMi initiative, and 4) proposes future steps that can be taken to improve the dissemination and acceptance of the proposed guidelines to manage QC.
To summarize, the principal goal of the QUAREP-LiMi initiative is to improve the overall quality and reproducibility of light microscope image data by introducing broadly accepted standard practices and accurately captured image data metrics.
The synthesis of a series of novel core-modified and fused-ring-expanded tetraphenylporphyrins is reported. Theoretical calculations and magnetic circular dichroism (MCD) and fluorescence spectroscopic measurements were used to analyze the effect of core modification with Group 16 oxygen, sulfur, selenium, and tellurium atoms on the optical properties and electronic structures of the porphyrins. Marked redshifts of the Q and B bands and accelerated intersystem-crossing rates were observed, thus making these compounds potentially suitable for use in a variety of applications. The scope for further fine-tuning of these optical properties based on additional structural modifications, such as the incorporation of fused benzene rings to form ABAB structures by using a thiophene precursor with a fused bicyclo[2.2.2]octadiene ring and the introduction of various substituents onto the meso-phenyl rings, is also examined.
The successful synthesis of tetraphenyltetraphenanthroporphyrin (TPTPhenP; 5a) in 2006 under modified Rothemund–Lindsey conditions yielded a tetraphenyl porphyrinoid with a B band redshifted to an unprecedented 576 nm. Radially symmetric fused-ring expansion of tetraphenylporphyrin with phenanthrene moieties results in very deep saddling due to steric crowding and very marked redshifts of the Q and B (or Soret) porphyrinoid absorption bands. The extent to which the TPTPhenP structure can be further modified is explored, and the optical properties of TPTPhenPs are analyzed based on a perimeter model approach that makes use of time-dependent DFT calculations and magnetic circular dichroism spectroscopy and also based on a detailed analysis of the fluorescence emission. Attempts to introduce substituents at the ortho and meta positions of the meso-phenyl groups and to insert a central metal proved unsuccessful. The synthesis of a series of TPTPhenPs with strong electron-withdrawing (—CN, —NO2) and -donating (—CH3, —N(CH3)2) substituents at the para positions of the meso-phenyl rings is reported. Marked redshifts of the main spectral bands were consistently observed. The most pronounced spectral changes were observed with —N(CH3)2 groups (5i) due to a marked destabilization of the HOMO, which has large MO coefficients on the meso-carbon atoms. Protonation of 5i at both the ligand core and at the —N(CH3)2 groups resulted in unprecedented Q00 band absorption at wavelengths greater than 1200 nm.