Filtern
Dokumenttyp
- Posterpräsentation (5) (entfernen)
Sprache
- Englisch (5)
Referierte Publikation
- nein (5)
Schlagworte
- FCM (2)
- Fluorescence (2)
- Bead-based assays (1)
- Calibration beads (1)
- Flow cytometry (1)
- Fluorescence standards (1)
- Lifetime-encoding (1)
- Nanogenotoxicity (1)
- Performance validation (1)
- Qdots (1)
Organisationseinheit der BAM
- 1.2 Biophotonik (5) (entfernen)
Time-resolved flow cytometry
(2019)
The fast identification of a large number of analytes or events is increasingly required in bioanalytical, diagnostic, and security applications. The versatility and straightforward use make multiparametric fluorescence techniques particularly interesting as detection techniques. An established method for high-throughput single-cell and single-particle measurements is flow cytometry (FCM). Using only spectral encoding without further intensity information, state-of-the-art instruments equipped with several light sources and detectors can resolve almost 20 different color codes. However, this is not sufficient to answer complex research questions, e.g. in cell biology and immunology. In contrast, routine applications demand low-cost and sometimes even portable instruments and thus a minimum number of instrument components. Thus, there are currently two main research directions in FCM: the development of methods that can either address increasingly complex analytical challenges or provide low-cost and robust approaches for routine multiplex analyses. Common spectral multiplexing approaches face limitations in both directions. On the one hand, spectral overlap of labels restricts the number of codes and makes elaborate correction schemes necessary. On the other hand, even for lower degrees of multiplexing often a sophisticated optical setup is needed. An alternative to spectral multiplexing and intensity encoding is to exploit the luminescence lifetime (LT) as an encoding parameter. This can allow for extending the parameter space in combination with spectral encoding or result in more simple and compact devices due to fewer optical components. The availability of fast electronics enables miniaturized and portable lifetime measurement setups at relatively low cost. LT-FCM requires to master LT determination with a limited number of detected photons due to the short interaction time of the encoded objects with the laser spot. In this study, we address this issue for time-domain cytometry and present a novel lifetime flow cytometry (LT-FCM) platform based on a compact setup and straightforward time-domain measurements utilizing LT-encoded luminescent beads. Moreover, we present the realization of a first bioanalytical assay with LT-encoded beads.
The overall interest in nanotoxicity, triggered by the increasing use of nanomaterials in the material and life sciences, and the synthesis of an ever increasing number of new functional nanoparticles calls for standardized test procedures and for efficient approaches to screen the potential genotoxicity of these materials. Aiming at the development of fast and easy to use, automated microscopic methods for the determination of the genotoxicity of different types of nanoparticles, we assess the potential of the fluorometric γH2AX assay for this purpose. This assay, which can be run on an automated microscopic detection system, relies on the detection of DNA double strand breaks (DSB) as a sign for genotoxicity. Here, we provide first results obtained with broadly used nanomaterials like CdSe/CdS and InP/ZnS quantum dots as well as iron oxide, gold, and polymer particles of different surface chemistry with previously tested colloidal stability and different cell lines like Hep-2 and 8E11 cells, which reveal a dependence of the genotoxicity on the chemical composition as well as the surface chemistry of these nanomaterials. These studies will be also used to establish nanomaterials as positive and negative genotoxicity controls or standards for assay performance validation for users of this fluorometric genotoxicity assay. In the future, after proper validation, this microscopic platform technology will be expanded to other typical toxicity assays.
Luminescence techniques are amongst the most commonly used analytical methods in life and material sciences due to their high sensitivity, nondestructive character, and easy instrumentation suitable for miniaturization. Photoluminescence signals are, however, affected by wavelength-, polarization-, and time-dependent instrument-related effects. Thus, at the core of standardization approaches for all fluorescence-based techniques are evaluated fluorescence standards for the consideration of instrument-specific spectral and intensity distortions of measured signals and for instrument performance validation (IPV).
Here, we summarize the research of BAM division 1.2 on development of liquid and solid fluorescence standards for various application-relevant fluorescence parameters and techniques. The portfolio of BAM fluorescence reference materials presently consists of:
i) a Spectral Fluorescence Standard Kit, i.e., a set of liquid fluorescence standards with certified normalized corrected emission spectra, for the determination of a broad variety of fluorescence parameters
ii) a ready-to-use, glass-based multi-emitter fluorescence standard for IPV and the determination of instrument-to-instrument variations
iii) specially adapted calibration tools and validation concepts for microarray-based platforms used in molecular diagnostics and food safety control
iv) quantum yield (Φf) standards for relative determination of the key performance parameter Φf of fluorescent materials, which can be also used for the evaluation of the performance of absolute, standard-free methods utilizing integrating sphere setups or spectrometer accessories. These materials, that will eventually cover the ultraviolet, visible, and near infrared spectral region, are currently under certification.
This toolbox of method-adapted reference materials can perfectly complement existing fluorescence standards. These easy-to-use, reference materials can pave the way to traceable fluorescence measurements to a radiometric scale like the spectral radiance or spectral photon radiance for all users of fluorescence techniques in material sciences and analysis, as well as environmental monitoring and biotechnology. They are particularly useful for customers working in strongly regulated areas like medical diagnostics or pharmaceutical research, where certified standards in conjunction with validated standard operating procedures are mandatory.
There is an increasing interest in bridging the gap between the photoluminescence (PL) properties of nanomaterials like semiconductor nanocrystals (QDs) commonly assessed in ensemble studies and the PL features of single QDs for life sciences applications such as bioimaging studies or use in microfluidic assays. The fluorescence quantum yield (ΦF) is a key performance parameter for all molecular and nanoscale emitters, increasingly employed in nanoscience, nanotechnology, and medical diagnostics.
ΦF determines not only the signal size together with the reporter´s molar extinction coefficient, yet it is particularly relevant for nanocrystals like QDs with coordinatively bound surface ligands and size- and surface chemistry-dependent PL characteristics.
The importance of ΦF measurements at ultralow concentration encouraged us to explore the potential of fluorescence correlation spectroscopy (FCS) for the relative determination of ΦF of ligand-stabilized CdTe nanocrystals in comparison to molecular dyes with closely matching spectral properties and known ΦF.
We describe a FCS-based method for the relative determination of ΦF of dispersed QDs at ultralow concentrations, and procedures to overcome QD-inherent challenges like complex and power-dependent blinking behavior as well as ligand- and QD-specific aggregation. We could demonstrate the potential of this approach by comparison with steady state ensemble measurements.
In all fluorescence-based techniques, the measured signals contain not only sample-related but also instrument-specific contributions, which limit the direct comparison of fluorescence data obtained e.g. on different devices or at different times and often hamper quantification. To rule out instrumentation as major source of variability of emission data, accepted fluorescence standards and procedures for the control of instrument specifications and long-term performance are required. For flow cytometry (FCM), a broad variety of fluorophore-stained polymer beads differing in emission wavelength and intensity is available for the testing of the alignment, sensitivity, and other parameters of FCM. These calibration tools are intended to facilitate the assessment of instrument performance to ensure reliable measurements and to improve the comparability of FCM experiments.
As a step towards an improved comparability of fluorescence data, with special emphasis on spectroscopic methods measuring nano- and micrometer-sized fluorescent objects, we are currently developing a set of fluorescent polystyrene (PS) beads loaded with luminophores from the certified BAM-Kit “Spectral fluorescent standards”, initially developed for the calibration of fluorescence spectrometers. Here, we present first results from studies of these fluorophore-loaded polymer beads. Moreover, new beads are made to supplement this kit by encapsulating near-infrared (NIR)-emissive luminophores in PS beads to cover the UV/VIS, and NIR wavelength range.
These beads are designed for calibration of flow cytometers and other fluorescence imaging systems to meet the increasing demand for reliable and comparable fluorescence data especially in strongly regulated areas like e.g. medical diagnostics.