KEY COMPARISON
At the October 2005 CCQM Organic Analysis Working Group Meeting (IRMM, Belgium), the decision was made to proceed with a Key Comparison study (CCQM-K47) addressing the calibration function for the determination of volatile organic compounds (VOCs) used for water quality monitoring. This was coordinated by CENAM and NIST. Benzene, o-xylene, m-xylene and p-xylene were chosen as representative VOCs. The solvent of choice was methanol.
Key Comparison CCQM-K47 demonstrated the capabilities of participating NMIs to identify and measure the four target VOCs in a calibration solution using GC-based methods. The measurement challenges in CCQM-K47, such as avoiding volatility loss, achieving adequate chromatographic resolution and isolating potential interferences, are typical of those required for value-assigning volatile reference materials. Participants achieving comparable measurements for all four VOCs in this Key Comparison should be capable of providing reference materials and measurements for VOCs in solutions when present at concentration levels greater than 10 µg/g.
Estrogens are endocrine disrupting chemicals and of high concerns due to demonstrated harmful effects on the environment and low effect levels. For monitoring and risk assessment, several estrogens were included in the "watch list" of the EU Water Framework Directive which sets very low environmental quality standard (EQS) levels for Estrone (E1) and 17β-Estradiol (E2) of 0.4 ng L−1 and for 17α-Ethinylestradiol (EE2) of 0.035 ng L−1 requiring sensitive detection methods, as well as extensive sample preparation. A sensitive, derivatization-free, isotope dilution calibration HPLC-MS/MS method for a panel of 5 selected estrogens (including the 3 estrogens of the EU WFD watchlist), and a procedure for the reproducible preparation of a representative whole water matrix including mineral water, humic acids and solid particulate matter are presented. These are used in a diligent comparison of classical solid phase extraction (SPE) on hydrophilic-lipophilic balanced (HLB) phase to SPE on an estrogen-specific molecularly imprinted polymer phase (MISPE) for ultra-trace levels of the analytes (1–10 ng L−1). Additionally, a two-step procedure combining HLB SPE disks followed by MISPE is evaluated. The tow-step procedure provides superior enrichment, matrix removal and sample throughput while maintaining comparable recovery rates to simple cartridge SPE. Estimated method quantification limits (MQLs) range from 0.109–0.184 ng L−1 and thus meet EQS-levels for E1 and E2, but not EE2. The representative whole water matrix provides a reproducible comparison of sample preparation methods and lays the foundation for a certified reference material for estrogen analysis. The presented method will serve as the basis for an extended validation study to assess its use for estrogen monitoring in the environment.
Bericht zur Durchführung des Ringversuchs zur Validierung der Benzolanalytik im Spurenbereich
(2006)
Im Auftrag des Altlastenausschusses (ALA) der Bund/Länder Arbeitsgemeinschaft Boden (LABO) wurde ein Validierungsringversuch für die Bestimmung von leichtflüchtigen monoaromatischen Verbindungen mit Hinweisen auf existierende Prüfwerte, wie BTEX in Boden, im Spurenbereich durchgeführt. 3 Bodenproben mit unterschiedlichen Kontaminationsniveaus der BTEX-Verbindungen, überschichtet mit Methanol, eine Bodenprobe dotiert mit Ottokraftstoff, Super bleifrei, eine BTEX-Standardlösung unbekannter Konzentration, sowie eine BTEX-Standardlösung mit zertifizierten Gehaltsangaben wurden an 21 ausgewählte Teilnehmer verschickt, die überwiegend mit GC-MS analysiert haben. Die Ergebnisse und die Verfahrenskenndaten zeigen, dass die Mehrzahl der Laboratorien mit den angewandten Analysentechniken in der Lage ist, in dem vorgegebenen Kontaminationsbereich empfindlich genug, vergleichbar und richtig messen zu können. GC- FID erweist sich nicht empfindlich und spezifisch genug in dem unteren Spurenbereich, deshalb war schon in dem Aufruf zum Ringversuch auf die Anwendung der GC-MS- Messtechnik verwiesen worden.
Bisphenol A (BPA) has been listed as a substance of very high concern (SVHC) due to its endocrine-disrupting properties according to REACH in 2017. European competent authorities have prepared a REACH restriction proposal to reduce BPA levels in the environment. The proposed limit for the concentration of free BPA and other bisphenols in articles is 10 mg kg−1. If exceeded, migration testing can demonstrate that no more than 0.04 mg L−1 is released from the product or material over its lifetime. German authorities are drafting a new restriction proposal after the original was temporarily withdrawn. The residual and migration limits mentioned above were key requirements from the previous restriction proposal. Numerous national and international standards exist for assessing how environmental factors affect the physical and chemical properties of products and materials—such as notch impact strength and tensile strength—but these standards do not cover the release of pollutants. A standardised procedure that covers all aspects of artificial weathering and monitors the subsequent release of pollutants is necessary, especially in the context of the regulation of these substances. An accelerated weathering procedure was established for non-protected samples. This material was not intended for outdoor applications. The testing procedure applied a typical weathering scenario that represents Central European climate conditions. The procedure was validated and applied to samples under distinct quality assurance aspects. Released BPA is quantified via an organic isotope dilution LC-MS/MS method. In parallel, identical samples were weathered outdoors on a weathering rack. Haze and yellowness index are measured to compare outdoor and weathering chamber results.
The CCQM-K78.b key comparison was coordinated by the Bureau International des Poids et Mesures (BIPM) on behalf of the CCQM Organic Analysis Working Group (OAWG) of the 'Comité Consultatif pour la Quantité de Matière' (CCQM), for National Measurement Institutes (NMIs) and Designated Institutes (DIs) providing measurement services in organic analysis under the 'Comité International des Poids et Mesures' (CIPM) Mutual Recognition Arrangement (MRA).
This key comparison was conducted as a 'Track A' comparison within the OAWG's 10-year strategic plan. The goal of CCQM-K78.b was to underpin capabilities for the value assignment of calibration solutions containing low polarity/non-polar organic analytes in organic solvents. The selected model system consisted of a two-component pesticide solution in acetonitrile, comprising methoxychlor and trifluralin.
Participants were tasked with assigning the mass fractions, in units of μg/g, of methoxychlor and trifluralin in acetonitrile solution. The mass fraction levels and analytical challenges of the selected analytes were representative of those encountered for calibration solutions of non-polar organic analytes. Participation in CCQM-K78.b allowed for the benchmarking of capabilities for assigning the mass fraction of non-polar organic compounds (pKow < -2) in solution, at mass fractions above 5 μg/g, in an organic solvent. Additionally, the comparison assessed the capabilities for the quantitative assignment of thermally labile compounds.
Participants were provided by the BIPM with ampoules containing methoxychlor and trifluralin in acetonitrile. Each participant reported the mass fraction content of each analyte in μg/g. All participants ensured the metrological traceability of their results through the use of a Primary Reference Material (PRM), which was used to prepare a primary calibrator solution for each analyte using a gravimetric procedure. The twenty participating institutes primarily used analysis procedures based on GC-MS, -IDMS, -MS/MS, -ECD, and -FID, with some participants also using LC-UV for the value assignment.
The analysis of methoxychlor and trifluralin in acetonitrile solution presented several challenges, including the thermal stability of the analytes under selected analytical techniques, control of solvent volatility, and considerable variation in some results using MS-based quantification methods. The mass fraction assignments for methoxychlor and trifluralin, consistent with the key comparison reference values (KCRVs), were achieved with associated relative standard uncertainties of (0.38 - 2.9) % for methoxychlor and (0.35 - 2.5) % for trifluralin.
To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/.
The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
BPA unterliegt einer kontinuierlichen behördlichen Kontrolle und ist als besonders besorgniserregender Stoff (SVHC) gelistet. Besondere Besorgnis besteht hinsichtlich seines häufigen Nachweises in Oberflächengewässern, obwohl es leicht biologisch abbaubar ist. In mehreren Studien wurden die Quellen und Wege von BPA in die Umwelt untersucht, wobei festgestellt wurde, dass seine Hauptverwendung als Monomer in PC nur marginal zu den BPA-Freisetzungen in die Umwelt über seinen Lebenszyklus beiträgt.
Um die tatsächlichen Freisetzungen von BPA aus PC unter umweltrelevanten Bedingungen besser zu verstehen, wurde eine neu entwickelte Methodik (Bundesanstalt für Materialforschung und -prüfung, BAM) angewendet, die ein neuartiges beschleunigtes Bewitterungsprotokoll für Polycarbonat-Materialien in Kombination mit einem sensitiven Analysenverfahren umfasst, welches eine Bestimmung von BPA im Ultraspurenbereich ermöglicht. Das Bewitterungsprotokoll erreicht eine 13,6-fache Beschleunigung im Vergleich zu mitteleuropäischen Wetterbedingungen und simuliert Umweltstressoren (globale Strahlung, Regen, Temperaturschwankungen) in einer Bewitterungskammer, wobei gleichzeitig die BPA-Freisetzung mit einem validierten LC-MS/MS-Verfahren unter Verwendung einer organischen Isotopenverdünnungskalibrierung bestimmt wird. In parallelen Freilandversuchen wurden die Trübung und die Vergilbung („Yellowness-Index“) der zu untersuchenden Proben als Referenzparameter untersucht.