Fire testing is an essential part of the hypothetical, cumulative mechanical and thermal test conditions that shall guarantee package safety in severe accidents. Within regulatory approval of transport or storage packages for radioactive material, specific thermal load tests are required in accordance to licensing conditions and international standards, respectively. The specifications of these thermal tests are based on test conditions with equivalent heat input to that of a hydrocarbon fuel fire. In the past, light heating oil, diesel or kerosene was mostly used as the fuel to generate the pool fire. In accordance with IAEA regulations for a fire in an accident, the temperature of 800 °C over a period of 30 minutes must be fulfilled. Furthermore, the delivery acceptance criteria for containers in nuclear waste repositories could reach for example average temperatures of 800 °C during a period of one hour in combination with defined requirements on activity release. BAM as a scientific and technical German federal government institute operates an open air Technical Safety Test Site for experimental investigations of dangerous good and its containment. In this areal a large fire test facility is under operation. Liquid Propane is utilized as fuel which is pumped via pipelines from a central storage tank to the fire exposed test facility areas. In the ring burner system, the gas is released from nozzles, and ignited by ignition burners. The paper includes examples of fire test performance with prototypes of a transport package and a storage container, respectively. In preparation of the thermal load, calorimeter tests have been performed using test specimens of appropriate size and behavior. For the fire test scenario is demonstrated that the IAEA thermal test requirements are fulfilled.
Fire testing is an essential part of the hypothetical, cumulative mechanical and thermal test conditions that shall guarantee package safety in severe accidents. Within regulatory approval of transport or storage packages for radioactive material, specific thermal load tests are required in accordance to licensing conditions and international standards, respectively. The specifications of these thermal tests are based on test conditions with equivalent heat input to that of a hydrocarbon fuel fire. In the past, light heating oil, diesel or kerosene was mostly used as the fuel to generate the pool fire. In accordance with IAEA regulations for a fire in an accident, the temperature of 800 °C over a period of 30 minutes must be fulfilled. Furthermore, the delivery acceptance criteria for containers in nuclear waste repositories could reach for example average temperatures of 800 °C during a period of one hour in combination with defined requirements on activity release. BAM as a scientific and technical German federal government institute operates an open air Technical Safety Test Site for experimental investigations of dangerous good and its containment. In this areal a large fire test facility is under operation. Liquid Propane is utilized as fuel which is pumped via pipelines from a central storage tank to the fire exposed test facility areas. In the ring burner system, the gas is released from nozzles, and ignited by ignition burners. The paper includes examples of fire test performance with prototypes of a transport package and a storage container, respectively. In preparation of the thermal load, calorimeter tests have been performed using test specimens of appropriate size and behavior. For the fire test scenario is demonstrated that the IAEA thermal test requirements are fulfilled.
In accident scenarios of transport packages or hypothetical crashes of containers in a storage facility or repository, the materials resistance against dynamic failure of the involved components is a deciding factor for package and container integrity during the handling, transport and storage for each type of radioactive material. For example, different dynamic impact tests on containers and components like lid sealing systems and specimens made of ductile cast iron and shock-absorbing materials are carried out by BAM. In order to perform dynamic impact tests with packages and its parts BAM operates two free-fall drop test facilities with maximum capacities of 200 t and 55 t, and a test bench for guided drop tests. This latter drop test machine enables a clearly specified component loading by a precisely positioned test object or drop weight and has been used recently for numerous investigations. The paper gives an overview of the wide range of experimental testing methods carried out within guided Impact and bending tests. Examples of methodological challenges are presented, especially such experimental analysis of dynamic impact conditions. In addition to known applied methods of dynamic, non-contact displacement measurements like high-speed 3-D surface deformation a recently patented 2-D tracking method is presented. By means of in-situ determination of fracture parameters with relevance to the materials stress intensity factor, the method has been successfully applied for a typical specimen geometry. Also shown are the possibility of detecting in-situ He-leakage rates on laterally impact loaded lid sealing systems as well as a method of acceleration sensor-temperature control under test conditions in the low temperature range.