Fire testing is an essential part of the hypothetical, cumulative mechanical and thermal test conditions that shall guarantee package safety in severe accidents. Within regulatory approval of transport or storage packages for radioactive material, specific thermal load tests are required in accordance to licensing conditions and international standards, respectively. The specifications of these thermal tests are based on test conditions with equivalent heat input to that of a hydrocarbon fuel fire. In the past, light heating oil, diesel or kerosene was mostly used as the fuel to generate the pool fire. In accordance with IAEA regulations for a fire in an accident, the temperature of 800 °C over a period of 30 minutes must be fulfilled. Furthermore, the delivery acceptance criteria for containers in nuclear waste repositories could reach for example average temperatures of 800 °C during a period of one hour in combination with defined requirements on activity release. BAM as a scientific and technical German federal government institute operates an open air Technical Safety Test Site for experimental investigations of dangerous good and its containment. In this areal a large fire test facility is under operation. Liquid Propane is utilized as fuel which is pumped via pipelines from a central storage tank to the fire exposed test facility areas. In the ring burner system, the gas is released from nozzles, and ignited by ignition burners. The paper includes examples of fire test performance with prototypes of a transport package and a storage container, respectively. In preparation of the thermal load, calorimeter tests have been performed using test specimens of appropriate size and behavior. For the fire test scenario is demonstrated that the IAEA thermal test requirements are fulfilled.
Packagings for the transport of dangerous goods need to meet special requirements to get an approval. This includes free fall drop testing onto an essentially unyielding surface as a means to assess a package’s resistance to mechanical damage. A main requirement for drop tests is that the impact target’s mass shall be at least 50 times that of the heaviest package to be tested. Nevertheless, many manufacturers do not possess foundation structures with the required mass ratio. Previous evidence highlights that the mass ratio is not a decisive criterion on its own. Parameters such as the impact target foundation’s connection and the impulse experienced by the impacting object are essential as well. However, these factors are not easily verifiable since experimental measurements are not possible at most facilities. The objective of this work is to provide a detailed analysis on the interaction between impact target foundation and subgrade in dynamic impact testing using validated finite-element (FE) models. This research is highly beneficial for industrial application since it allows manufacturers to make informed predictions about the mechanical response of installed impact target foundations.