Filtern
Erscheinungsjahr
Dokumenttyp
Sprache
- Englisch (18)
- Deutsch (4)
- Mehrsprachig (1)
Schlagworte
- Flow cytometry (2)
- Standard measurement procedure (2)
- XAFS (2)
- 17 beta-Estradiol (1)
- 3D ultrastructural analysis (1)
- AFM (1)
- Absolute dose (1)
- Acquired immunodeficiency syndrome (1)
- Additive manufacturing (1)
- Adhesion (1)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (2)
- 6 Materialchemie (2)
- 1.1 Anorganische Spurenanalytik (1)
- 1.5 Proteinanalytik (1)
- 1.8 Umweltanalytik (1)
- 4 Material und Umwelt (1)
- 4.1 Biologische Materialschädigung und Referenzorganismen (1)
- 5 Werkstofftechnik (1)
- 5.1 Mikrostruktur Design und Degradation (1)
- 6.2 Material- und Oberflächentechnologien (1)
Under the auspices of the Protein Analysis Working Group (PAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) a pilot study, CCQM-P216, was coordinated by the Chinese National Institute of Metrology (NIM), National Research Council of Canada (NRC) and the Bureau International des Poids et Mesures (BIPM). Eleven Metrology Institutes or Designated Institutes and the BIPM participated in the first phase of the pilot study (Part 1). The purpose of this pilot study was to develop measurement capabilities for larger proteins using a recombinant humanized IgG monoclonal antibody against Spike glycoprotein of SARS-CoV-2 (Anti-S IgG mAb) in solution. The first phase of the study was designed to employ established methods that had been previously studies by the CCQM Protein Analysis Working Group, involving the digestion of protein down to the peptide or amino acid level. The global coronavirus pandemic has also led to increased focus on antibody quantitation methods. IgG are among the immunoglobulins produced by the immune system to provide protection against SARS-CoV-2. Anti-SARS-CoV-2 IgG can therefore be detected in samples from affected patients. Antibody tests can show whether a person has been exposed to the SARS-CoV-2, and whether or not they potentially show lasting immunity to the disease. With the constant spread of the virus and the high pressure of re-opening economies, antibody testing plays a critical role in the fight against COVID-19 by helping healthcare professionals to identify individuals who have developed an immune response, either via vaccination or exposure to the virus. Many countries have launched large-scale antibody testing for COVID-19. The development of measurement standards for the antibody detection of SARS-CoV-2 is critically important to deal with the challenges of the COVID-19 pandemic. In this study, the SARS-CoV-2 monoclonal antibody is being used as a model system to build capacity in methods that can be used in antibody quantification. Amino acid reference values with corresponding expanded uncertainty of 36.10 ± 1.55 mg/kg, 38.75 ± 1.45 mg/kg, 18.46 ± 0.78 mg/kg, 16.20 ± 0.67 mg/kg and 30.61 ± 1.30 mg/kg have been established for leucine, valine, phenylalanine, isoleucine and proline, respectively. Agreement between nearly all laboratories was achieved for the amino acid analysis within 2 to 2.5 %, with one participant achieving markedly higher results due to a technical issue found in their procedure; this result was thus excluded from the reference value calculations. The relatively good agreement within a laboratory between different amino acids was not dissimilar to previous results for peptides or small proteins, indicating that factors such as hydrolysis conditions and calibration procedures could be the largest sources of variability. Peptide reference values with corresponding expanded uncertainty of 4.99 ± 0.28 mg/kg and 6.83 ± 0.65 mg/kg have been established for ALPAPIEK and GPSVFPLAPSSK, respectively. Not surprisingly due to prior knowledge from previous studies on peptide quantitation, agreement between laboratories for the peptide-based analysis was slightly poorer at 3 to 5 %, with one laboratory's result excluded for the peptide GPSVFPLAPSSK. Again, this level of agreement was not significantly poorer than that achieved in previous studies with smaller or less complex proteins. To reach the main text of this paper, click on Final Report.
Single Femtosecond Laser-Pulse-Induced Superficial Amorphization and Re-Crystallization of Silicon
(2021)
Superficial amorphization and re-crystallization of silicon in <111> and <100> orientation after irradiation by femtosecond laser pulses (790 nm, 30 fs) are studied using optical imaging and transmission electron microscopy. Spectroscopic imaging ellipsometry (SIE) allows fast data acquisition at multiple wavelengths and provides experimental data for calculating nanometric amorphous layer thickness profiles with micrometric lateral resolution based on a thin-film layer model. For a radially Gaussian laser beam and at moderate peak fluences above the melting and below the ablation thresholds, laterally parabolic amorphous layer profiles with maximum thicknesses of several tens of nanometers were quantitatively attained. The accuracy of the calculations is verified experimentally by high-resolution transmission electron microscopy (HRTEM) and energy dispersive X-ray spectroscopy (STEM-EDX). Along with topographic information obtained by atomic force microscopy (AFM), a comprehensive picture of the superficial re-solidification of silicon after local melting by femtosecond laser pulses is drawn.
Der zukünftige Eurocode 7 wird ausdrücklich die Nutzung zuverlässigkeitsbasierter Methoden in der geotechnischen Planung und Bemessung erlauben. In Deutschland gibt es bisher kaum Erfahrung in der praktischen Anwendung derartiger Verfahren und entsprechend sind die Vorbehalte gegenüber diesen Methoden oft groß. Der neue DGGT-Arbeitskreis (AK) 2.15 „Zuverlässigkeitsbasierte Methoden in der Geotechnik“ hat sich zum Ziel gesetzt, durch praxisorientierte Anleitungen und Empfehlungen sowie begleitende Aus- und Weiterbildungsangebote den praktischen Zugang zu diesen Verfahren zu unterstützen. Ziel ist es, Möglichkeiten und Grenzen zu verdeutlichen sowie vor allem ihre Potenziale zu erschließen. In dem vorliegenden Beitrag werden allgemeine Grundlagen und die zukünftigen Arbeitsfelder des AK 2.15 vorgestellt. Ausgehend von der Einführung relevanter Fachbegriffe wird zunächst die Einbettung zuverlässigkeitsbasierter Verfahren in den aktuellen Normungs- und Regelungskontext aufgezeigt. Anschließend werden anhand des Lebenszyklus eines geotechnischen Bauwerks die Unsicherheiten in den geotechnischen Prognosen und Bewertungen beschrieben. Daran anknüpfend wird aufgezeigt, an welchen Stellen zuverlässigkeitsbasierte Methoden als mögliches Werkzeug sinnvoll genutzt werden können, um Ingenieur:innen, Bauherr:innen und Prüfer:innen in Nachweis- und Entscheidungsprozessen zu unterstützen. Zu den sich daraus ableitenden Arbeitsthemen werden durch den AK 2.15 zukünftig Empfehlungen erarbeitet und sukzessive veröffentlicht