Fireballs of liquid organic peroxides differ from those of liquid hydrocarbon fuels. Modified equations for predicting the fireball diameter, height, surface emissive power and the duration in dependence of the fuel mass are presented for di-tert-butyl peroxide. They base on 13 steel drum tests with fuel masses from 10 kg to 168 kg. Moreover, computational fluid dynamics simulations are performed using the laminar flamelet approach and a statistically turbulence treatment. Fireballs involving peroxide from 10 kg to 80 kg were simulated and their properties compared to the experimentally developed models. The deviations of each property are partially compensating each other leading to an adequate prediction of thermal safety distances for both, a time-independent and a time-averaged treatment. Simulations prove to be a good tool for predicting thermal radiation hazards of fireball scenarios.
The thermal radiation impact of organic peroxide fireballs is experimentally assessed using an infrared camera. Fireballs are generated while liquid peroxide filled steel drums are subjected to gas burner fire at different heating rates. Three large burning clouds are observed with varying flame characteristics. Thermal radiation properties are assessed by infrared images with the presented methods. Despite of the two-dimensional temperature fields, the flames are treated and characterized as three-dimensional objects. Fireball diameters and heights are calculated based on a representing radiating sphere with the same cloud volume. By the use of the solid flame model and assumptions for emissivity and transmissivity, heat fluxes and thermal radiation doses against distance are predicted. Thermal safety distances are presented based on the maximum irradiance and the allowed exposure time. The validation of the maximum and time-dependent radiation fields is achieved through heat flux sensors in varying distances to the fireball. The results prove the use of an infrared camera and a volume based size calculation to fully assess the thermal radiation hazards of fireballs.
Organic peroxides are capable to form fireballs with explosive violence. Only fireball models for liquid hydrocarbon fuels are available for the assessment of the thermal radiation properties. Because the development of such fireballs usually differ from those of organic peroxides the properties need to be characterized by modified equations. In this study liquid organic peroxide fireballs from 16 kg to 155 kg substance masses are characterized and compared to selected existing correlations. Flame characteristics and irradiances are measured with infrared cameras and heat flux sensors. All fireballs are consequences of simulated worst case scenarios where filled steel drums are engulfed by fire with varying heat impact. The differences of the given semi-empirical equations and the presented experimental work are explained. A new model is proposed for organic peroxide fireballs by modifying the constants of the known equations. The thermal radiation impact and safety distances are calculated and compared.
Single and multiple fireballs of di-tert-butyl peroxide are numerically investigated using ANSYS CFX. Calculations contain varying inlet conditions, scale-adaptive shear stress turbulence modeling and one-step combustion reaction on a three-dimensional hexahedral mesh. Time-resolved flame temperatures, sizes and thermal radiation are compared to experimental results. There, fireballs were generated by fire engulfment of steel drums containing 200 l substance. After a vigorous burning, the remaining peroxide forms single and multiple fireballs involving 10 % to 20 % of the initial amount. The comparison of all simulations and two selected experiments show the special numerical treatment required for organic peroxides. Finally, the numerical predictions of irradiance in 30 m distance to the fire show a good agreement for both experiments. This proves the use of CFD as an appropriate method for thermal hazard assessment and the prediction of safety distances for organic peroxide fireballs.
To simulate a full fire engulfment during transportation or storage a closed removable head steel drum filled with 200 l Di-tert-butyl peroxide (DTBP) is subjected to a wood fire. Due to the enormous heat flux and the exothermic self-decomposition large flames arise and finally multiple fireballs occur. The fireballs consume up to 20 % of the total mass (20 % equals to 31 kg). They are characterized by high surface emissive power and large flames associated with high thermal radiation causing spontaneous ignition of objects in the surrounding. The measured sizes of the DTBP fireballs are smaller compared to the results of the general equations for hydrocarbon fireballs. Because these equations are recommended by the Health and Safety Executive (UK) to be applicable for organic peroxides explicit comparisons of DTBP with LPG, diesel and gasoline concerning the characteristics of fireballs are carried out. Also the burning time is compared and confirms a faster combustion of the peroxide. Moreover, the development of size and emissive power for DTBP and diesel fireballs are compared in a normalized graph. The results provide the assumption that new empirical models are required to be developed for hazard assessment of organic peroxide fireballs.