Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (116)
- Zeitschriftenartikel (96)
- Posterpräsentation (25)
- Forschungsbericht (11)
- Beitrag zu einem Sammelband (9)
- Beitrag zu einem Tagungsband (7)
- Buchkapitel (3)
- Sonstiges (2)
- Forschungsdatensatz (1)
Schlagworte
- Traceability (34)
- Metrology (32)
- IDMS (19)
- Absolute isotope ratio (18)
- Isotope ratio (17)
- Uncertainty (16)
- CCQM (11)
- Measurement uncertainty (11)
- ICP-MS (10)
- Reference material (10)
- TIMS (10)
- Delta value (9)
- ICPMS (8)
- Isotope reference materials (8)
- Mass spectrometry (8)
- Copper (7)
- Reference materials (7)
- Cement (6)
- Comparability (6)
- Isotope fractionation (6)
- Isotope reference material (6)
- Metrology in chemistry (6)
- Atomic weight (5)
- Conventional isotope ratio (5)
- Delta reference materials (5)
- Herkunft (5)
- Isotope amount ratio (5)
- Isotope dilution (5)
- Magnesium (5)
- Purity (5)
- Sulfur (5)
- Triple isotope fractionation (5)
- Boron isotopes (4)
- Cadmium (4)
- Certification (4)
- Delta scale (4)
- Human serum (4)
- Interlaboratory comparison (4)
- Isotope (4)
- Isotope delta value (4)
- Isotope dilution mass spectrometry (4)
- Isotope ratios (4)
- Lead (4)
- MC-ICP-MS (4)
- Molar mass (4)
- Provenance (4)
- Purity assessment (4)
- SI traceability (4)
- Stable isotopes (4)
- Zinc (4)
- Archaeometry (3)
- Boron isotope variations (3)
- Delta values (3)
- Delta-scale (3)
- Iron (3)
- Isotopes (3)
- Lead isotopes (3)
- Palladium (3)
- Platinum (3)
- Synthetic isotope mixtures (3)
- Automotive exhaust emissions (2)
- Biodiesel (2)
- Biodiesel fuel (2)
- Bor (2)
- Boron (2)
- Boron isotope fractionation (2)
- CMC (2)
- Calibration (2)
- Circular economy (2)
- Geochemistry (2)
- Geological material (2)
- IRM (2)
- Isotope Dilution (2)
- Isotope delta (2)
- Isotopenverhältnisse (2)
- Lithium (2)
- Magnesium isotope ratios (2)
- Milk (2)
- Provenance studies (2)
- SI (2)
- SI-traceability (2)
- Silicon (2)
- Sr isotopes (2)
- Surface analysis (2)
- TCE (2)
- Tetramethylammonium hydroxide (2)
- Transferrin (2)
- Uncertainty budget (2)
- boron (2)
- metrology (2)
- traceability (2)
- 87Sr/86Sr (1)
- AAS (1)
- Absolute Isotopenverhältnisse (1)
- Absolute isotope abundance (1)
- Algorithms (1)
- Alzheimer disease (1)
- Alzheimer’s disease (1)
- Amyloid-beta (1)
- Analyte-matrix separation (1)
- Analytical Chemistry (1)
- Analytical uncertainty (1)
- Antikensammlung Berlin (1)
- App (1)
- Archaeology (1)
- Archäometrie (1)
- Areal density (1)
- Argon (1)
- Ash content (1)
- Atomic Absorption Spectrometry (1)
- Atomic absorption spectrometry (1)
- Atomic weights (1)
- Authenticity (1)
- Automotive pollution (1)
- Avogadro constant (1)
- Bell (1)
- Bell pepper (1)
- Bioapatite (1)
- Biogenic carbonates (1)
- Biological boron recycling (1)
- Blank characterization (1)
- Blei (1)
- Blei-Isotopie (1)
- Bodenanalyse (1)
- Boron isotope (1)
- Boron isotopes in food (1)
- Boron isotopic composition (1)
- Boron monohydride (1)
- Boron transport (1)
- Brain (1)
- Branching ratio (1)
- Brassica napus (1)
- CCQM-P107 (1)
- CE/MC-ICP-MS (1)
- CRM (1)
- Calcification (1)
- Calcium (1)
- Catalytic converters (1)
- Cationic exchange (1)
- Cattle (1)
- Cconventional method (1)
- Cd mass fraction (1)
- Central Taurus (1)
- Cheese (1)
- Chenopodium album (1)
- Chromium (1)
- Ciaaw.org (1)
- Classical oven-drying (1)
- Classical primary measurement method (CPM) (1)
- Commercial moisture analyzer (1)
- Comparison (1)
- Conventional isotope ratios (1)
- Conventional method (1)
- Counting detector (1)
- Cross sections (1)
- Cu-64 (1)
- Curse tablets (1)
- Dairy cows (1)
- Data processing (1)
- Dead time (1)
- Degree of equivalence (1)
- Delta isotope standard (1)
- Delta notation (1)
- Delta-RM (1)
- Dementia (1)
- Detector deadtime (1)
- Determination of metrology of new cadmium atomic weight (1)
- Development (1)
- Diagenesis (1)
- Direct metal assay (1)
- Dissolution (1)
- Double IDMS (1)
- Double isotope dilution (1)
- Dual mode detector (1)
- EPMA (1)
- ERM (1)
- EURAMET (1)
- Elemental composition (1)
- Elemental fingerprints (1)
- Elemental mass spectrometry (1)
- Elementanalyse (1)
- Emissionen (1)
- Enriched isotope (1)
- Erythrocytes (1)
- Faecal monitoring (1)
- Feed (1)
- Feeding regime (1)
- Finow Canal (1)
- Fluchtafel (1)
- Food (1)
- Fossil fuel (1)
- Fuel (1)
- Fundamental science (1)
- GDMS (1)
- Graphite furnace (1)
- Gravimtric isotope mixtures (1)
- Greek curse tablets (1)
- Green Deal (1)
- Gypsum (1)
- HR-CS-MAS (1)
- Hafnium (1)
- Heavy metals (1)
- High purity metals (1)
- High-fired gypsum mortar (1)
- High-purity elements (1)
- High-resolution continuum source absorption spectrometry (1)
- High-resolution continuum source graphite furnace atomic absorption spectrometry (1)
- Hydrothermal fluid (1)
- Hyphenated (1)
- ICP-OES (1)
- ICP-TOFMS (1)
- ICP-ToF-MS (1)
- ID-ICP-MS (1)
- ID-MS (1)
- ILC (1)
- IMEP-9 (1)
- IUPAC Inorganic chemistry division (1)
- Iinductively coupled plasma mass spectrometry (1)
- Impurities (1)
- Impurity assessment (1)
- Impurity assessment approach (1)
- In-house calibration solution (1)
- Inductively coupled plasma (ICP) mass spectrometry (1)
- Inorganic chemical analysis (1)
- Inorganic impurities (1)
- Instrumental isotope fractionation (1)
- Interferences (1)
- Intra-plant isotope variability (1)
- Iridium (1)
- Iron isotope fractionation (1)
- Isobaric interferences (1)
- Isotope abundance (1)
- Isotope amount ratios (1)
- Isotope mixture (1)
- Isotope mixtures (1)
- Isotope purification (1)
- Isotope ratio mass spectrometry (1)
- Isotopenverhältnisse Strontium und Blei (1)
- Isotopenzusammensetzung (1)
- Isotopic Reference Material (1)
- Isotopic abundance variations (1)
- Isotopic analysis (1)
- Isotopic composition (1)
- Isotopic fractionation (1)
- Kalke (1)
- Karl Fischer titration (1)
- Kernkraftwerk (1)
- Kernkraftwerke (1)
- Kilogram (1)
- Königswasserextraktion (1)
- LA-(MC-)ICP-MS (1)
- LA-ICP-MS (1)
- LSVEC (1)
- Lagerstätten (1)
- Laser ablation (1)
- Lead isotope composition (1)
- Lead isotope ratios (1)
- Lead isotope variations (1)
- Lead isotopic composition (1)
- Legacy pollution (1)
- Low sulfur (1)
- MC-TIMS (1)
- MDG (1)
- MW-AES (1)
- Machine learning (1)
- Magnesium absorption (1)
- Magnesium stable isotopes (1)
- Mangesium (1)
- Mass discrimination (1)
- Mass fractionation (1)
- Massenspektrometrie (1)
- Matrix samples (1)
- Matrix separation (1)
- Measurement space (1)
- Measuremment uncertainty (1)
- Memory effect (1)
- Mercury (1)
- Mercury speciation (1)
- Metal assay approach (1)
- Metal sublimation (1)
- Methylmercury (1)
- Metrology in Chemistry (1)
- Micro-sublimation (1)
- Microbially induced corrosion (1)
- Mittelalterliche Pilgerzeichen (1)
- Moisture (1)
- Mole (1)
- Molecular absorption (1)
- Multi-collector ICP-MS (1)
- Multi-collector inductively coupled plasma-mass spectrometry (ICP-MS) (1)
- Multi-element screening (1)
- Multicollector inductively coupled plasma mass spectrometry (1)
- NTD (1)
- Nanoparticles (1)
- Neutron activation (1)
- Neutron transmutation doping (1)
- Nickel (1)
- Nitrogen microwave inductively coupled atmospheric pressure mass spectrometry (1)
- Noise (1)
- Non-metal analysis (1)
- Open vessel digestion (1)
- Optimization (1)
- Ore provenance (1)
- PERM (1)
- PGE (1)
- PTI-MS (1)
- Pb isotope ratio thermal ionization mass spectrometry (1)
- Pb isotopes (1)
- Pepper (1)
- Petrol (1)
- Plant metabolism (1)
- Plant tissue (1)
- Plants (1)
- Platinum group elements (PGE) (1)
- Polarised light microscopy (1)
- Polyethylene (1)
- Polypropylene (1)
- Pore fluids (1)
- Portland cement (1)
- Portland clinker (1)
- Priam's treasure (1)
- Primary Isotopic Reference Material (1)
- Primary calibration solution (1)
- Primary difference measurement method (PDM) (1)
- Primary method of measurement (1)
- Primary transfer standards (PTSs) (1)
- Primäres Isotopenreferenzmaterial (1)
- Provenancing (1)
- Purity analysis (1)
- Purity determination (1)
- Quality system (1)
- Quantitative protein analysis (1)
- Radiogenic isotopes (1)
- Raman microspectroscopy (1)
- Raman spectroscopy (1)
- Re-evaluation (1)
- Reference data (1)
- Reference measurement (1)
- Reference measurement procedures (1)
- Reference measurements (1)
- Reference procedure (1)
- Review (1)
- Revision of the SI (1)
- River water (1)
- SF-ICP-MS (1)
- Sample-sample bracketing (1)
- Scale anchor (1)
- Scale conversion (1)
- Schwermetallbestimmung (1)
- Selenium (1)
- Serum (1)
- Silver artefacts (1)
- Single IDMS (1)
- Single Particle (1)
- Soil (1)
- Soil available boron (1)
- Spike (1)
- Sr and Nd isotope analysis (1)
- Sr isotope analysis (1)
- Stable isotope (1)
- Standard addition (1)
- Standard atomic weight (1)
- Statistical analysis (1)
- Strontium isotope (1)
- Strontium isotope ratio (1)
- Sulfur in oil (1)
- Sulphur (1)
- Sulphur isotope (1)
- Synthetic mixtures (1)
- TIMs (1)
- Tau (1)
- Technology-critical elements (1)
- Terminology (1)
- Thermal ionization mass spectrometry (1)
- Thermionenmassenspektrometrie (1)
- Thermogravimetry (1)
- Total element determination (1)
- Toxic elements (1)
- Transient signal (1)
- Triple IDMS (1)
- Trojan silver artefacts (1)
- Trophic level (1)
- Unsicherheitsvergleiche (1)
- Uranium (1)
- Urinary monitoring (1)
- Urine (1)
- Validate method (1)
- Value assignment (1)
- WD-XRF (1)
- Water (1)
- Wet digestion (1)
- Wood chips (1)
- XRCD method (1)
- Ytterbium (1)
- absolute measurements (1)
- atomic weight (1)
- bell pepper (1)
- collision cell (1)
- delta value (1)
- enriched isotope (1)
- interferences (1)
- isotope fractionation (1)
- isotope ratio (1)
- isotope reference material (1)
- key comparison (1)
- lank characterization (1)
- magnesium (1)
- mass spectrometry (1)
- measurement uncertainty (1)
- metabolism (1)
- multi-collector (1)
- purity (1)
- reference material (1)
- silicon (1)
- species-specific isotope information (1)
- tandard addition (1)
- uncertainty budget (1)
- Ägyptisches Museum Berlin (1)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (87)
- 1.1 Anorganische Spurenanalytik (87)
- 1.3 Instrumentelle Analytik (3)
- 1.4 Prozessanalytik (3)
- 1.6 Anorganische Referenzmaterialien (3)
- P Präsident (3)
- P.0 Präsident und andere (3)
- S Qualitätsinfrastruktur (3)
- S.1 Qualität im Prüfwesen (3)
- 1.7 Organische Spuren- und Lebensmittelanalytik (2)
Eingeladener Vortrag
- nein (116)
The development and implementation of a method for the certification of cadmium in blood samples at low ng g-1 and sub ng g-1 levels is described. The analytical procedure is based on inductively coupled plasma isotope dilution mass spectrometry (ICP-IDMS) applied as a primary method of measurement. Two different sample digestion methods, an optimized microwave digestion procedure using HNO3 and H2O2 as oxidizing agents and a high-pressure asher digestion procedure, were developed and compared. The very high salt content of the digests and the high molybdenum content, which can cause oxide-based interferences with the Cd isotopes, were reduced by a chromatographic matrix separation step using an anion-exchange resin. All isotope ratio measurements were performed by a quadrupole ICP-MS equipped with an ultrasonic nebulizer with membrane desolvator. This sample introduction set-up was used to increase sensitivity and minimize the formation of oxides (less MoO+ interference with the Cd isotopes).
Because of the very low Cd concentrations in the samples and the resulting need to minimize the procedural blank as much as possible, all sample-processing steps were performed in a clean room environment. Detection limits of 0.005 ng g-1 Cd were achieved using sample weights of 2.7 g. The method described was used to re-certify the cadmium content of three different blood reference materials from the Community Bureau of Reference (BCR) of the European Commission (BCR-194, BCR-195, BCR-196). Cadmium concentrations ranged between ~0.2 ng g-1 and ~12 ng g-1. For these materials, SI-traceable certified values including total uncertainty budgets according to ISO and Eurachem guidelines were established.
The stable carbon and nitrogen isotopic composition of urine and milk samples from cattle under different feeding regimes were analysed over a period of six months. The isotope ratios were measured with isotope ratio mass spectrometry (IRMS). The δ13C values of milk and urine were dependent on different feeding regimes based on C3 or C4 plants. The δ13C values are more negative under grass feeding than under maize feeding. The δ13C values of milk are more negative compared to urine and independent of the feeding regime. Under grass feeding the analysed milk and urine samples are enriched in 13C relative to the feed, whereas under maize feeding the 13C/12C ratio of urine is in the same range and milk is depleted in 13C relative to the diet. The difference between the 15N/14N ratios for the two feeding regimes is less pronounced than the 13C/12C ratios. The δ15N values in urine require more time to reach the new equilibrium, whereas the milk samples show no significant differences between the two feeding regimes.
The present paper describes the certification of the amount content of Cd, Cr and Pb in two different polyethylene materials within the third phase of the Polyethylene Elemental Reference Material (PERM) project. The analytical procedure to establish the reference values for Cd, Cr and Pb amount contents in these materials is based on isotope dilution mass spectrometry used as a primary method of measurement. Cd and Pb were measured with inductively coupled plasma-mass spectrometry and Cr with positive thermal ionization-mass spectrometry. The decomposition of the polymer matrix was carried out using a high pressure asher. Reference values for amount content, traceable to the SI-system, have been obtained for these three elements in both of the polyethylene samples of PERM. For each of the certified amount content values an uncertainty budget was calculated using the method of propagation of uncertainties according to ISO and EURACHEM guidelines. The measurement procedures, as well as the uncertainty calculations, are described for all three elements. In order to keep the whole certification process as transparent as possible, the preparations of various reagents and materials as well as the sample treatment and blending are described in detail. The mass spectrometry measurements and the data treatment are also explained carefully. The various sources of uncertainty present in the procedure are displayed in the uncertainty budgets. The obtained combined uncertainties for the amount content values were less than 2% relative (k=1) for all investigated elements. The amount contents were in the ?mol/kg range, corresponding to mg/kg levels.
Comparative performance study of ICP mass spectrometers by means of U "isotopic measurements"
(2000)
The performance of four commercially available ICPMS instruments of three different types was compared by means of uranium "isotopic measurements". Examined were two quadrupole sector (different generation, different manufacturer), one single detector double focusing magnetic sector and one multiple collector double focusing magnetic sector instruments. The same samples of the IRMM-072 series were used under routine conditions to measure the 233U/235U and the 233U/238U ratios which, in these samples, vary over almost three orders of magnitude from ~ 1 to ~ 2 · 10-3. Within expanded (k = 2) uncertainties, good agreement was observed between the certified values and the data internally corrected for mass-discrimination effects. The magnitude of the evaluated uncertainties was different for each type of instrument. With the multiple collector instrument, expanded uncertainties varied from - 0.04% to- 0.24% for the 233U/235U ratio, and from - 0.08% to - 0.27% for the 233U/238U ratio. They were ~ 1 to 5 times larger with the single detector magnetic sector instrument, and ~ 10 to 25 times larger with both quadrupole sector instruments. With the multiple collector instrument, repeatability of the measurements seemed to be limited by the difficulty of correcting properly for instrumental background, whereas with the single detector magnetic sector instrument the counting statistics was the only limitation (on smallest ratios). Apparent mass-discrimination was clearly found to be larger but more reproducible (and hence easier to correct for) in the case of magnetic sector instruments than for both quadrupole sector instruments. If space charge effects were the main source of mass-discrimination for all instruments, these results are in contradiction with the hypothesis of the size of mass-discrimination decreasing with the acceleration voltage. With the single detector magnetic sector instrument in particular (when operated by changing the ion energy only), our results pointed at more than only one major source of mass-discrimination, with variable size depending on the ratios measured.
The article gives a condensed version of the keynote lecture held at the International Mass Spectrometry Conference 2012 in Kyoto. Starting with some examples for isotope research the key requirements for metrologically valid procedures enabling traceable and comparable isotope data are discussed. Of course multi-collector mass spectrometers are required which offer sufficiently high isotope ratio precision for the intended research work. Following this, corrections for mass fractionation/discrimination, validation of the analytical procedure including chemical sample preparation and complete uncertainty budgets are the most important issues for obtaining a metrologically valid procedure for isotope ratio determination. Only the application of such metrologically valid procedures enables the generation of traceable and comparable isotope data. To realize this suitable isotope and/or δ-reference materials are required, which currently are not sufficiently available for most isotope systems. Boron is given as an example, for which the situation regarding isotope and δ-reference materials is excellent. Boron may therefore serve as prototype for other isotope systems.
Triple IDMS has been applied for the first time to the quantification of element concentrations. It has been compared with single and double IDMS obtained on the same sample set in order to evaluate the advantages and disadvantages of triple IDMS over single and double IDMS as an analytical reference procedure. The measurement results of single, double and triple IDMS are indistinguishable, considering rounding due to the individual measurement uncertainties. As expected, the relative expanded uncertainties (k = 2) achieved with double IDMS (0.08 %) are dramatically smaller than those obtained with single IDMS (1.4 %). Triple IDMS yields the smallest relative expanded uncertainties (k = 2, 0.077 %) unfortunately at the expense of a much higher workload. Nevertheless triple IDMS has the huge advantage that the isotope ratio of the spike does not need to be determined. Elements with high memory effects, highly enriched spikes or highest metrological requirements may be typical applications for triple IDMS.
Die Industrie nutzt die Borisotopenanalytik in nukleartechnischen Anwendungen. Umwelt- und Geowissenschaften identifizieren anhand der Borisotopenverhältnisse Kontaminationsquellen und charakterisieren Mischungs- und Fraktionsprozesse. In der Lebensmittelanalytik dient der Parameter dazu, Herkunft und Anbauweise von Obst und Gemüse herauszufinden. Seit kurzem gibt es dafür ein validiertes Verfahren und erste Referenzdaten.
Analytische Methoden zur Feststellung der Herkunft eines Baustoffes sind bislang kaum entwickelt worden. In Deutschland gibt es eine Reihe von Kalkiagerstätten, die in unterschiedlichen geologischen Formationen Kalk oder Dolomit enthalten. Das unterschiedliche geologische Alter von Kalken sowie die ursprüngliche mineralische Zusammensetzung und die geologische Historie spiegeln sich im 87Sr/88Sr-lsotopenverhältnis weder. Mittels der Thermionen-Massenspektrometrie kann dieses Verhältnis ermittelt und somit zur Herkunftsbestimmung eines Kalkes herangezogen werden.
Isotopic reference materials are essential to enable reliable and comparable isotope data. In the case of boron only a very limited number of such materials is available, thus preventing adequate quality control of measurement results and validation of analytical procedures. To address this situation a unique set of two boron isotope reference materials (ERM-AE102a and -AE104a) and three offset δ11B reference materials (ERM-AE120, -AE121 and -AE122) were produced and certified. The present article describes the production and certification procedure in detail. The isotopic composition of all the materials was adjusted by mixing boron parent solutions enriched in 10B or 11B with a boron parent solution having a natural isotopic composition under full gravimetric control. All parent solutions were analysed for their boron concentration as well as their boron isotopic composition by thermal ionisation mass spectrometry (TIMS) using isotope dilution as the calibration technique. For all five reference materials the isotopic composition obtained on the basis of the gravimetric data agreed very well with the isotopic composition obtained from different TIMS techniques. Stability and homogeneity studies that were performed showed no significant influence on the isotopic composition or on the related uncertainties. The three reference materials ERM-AE120, ERM-AE121 and ERM-AE122 are the first reference materials with natural δ11B values not equal to 0. The certified δ11B values are -20.2 for ERM-AE120, 19.9 for ERM-AE121 and 39.7 for ERM-AE122, each with an expanded uncertainty (k = 2) of 0.6. These materials were produced to cover about three-quarters of the known natural boron isotope variation. The 10B enriched isotope reference materials ERM-AE102a and ERM-AE104a were produced for industrial applications utilising 10B for neutron shielding purposes. The certified 10B isotope abundances are 0.29995 for ERM-AE102a and 0.31488 for ERM-AE104a with expanded uncertainties (k = 2) of 0.00027 and 0.00028, respectively. Together with the formerly certified ERM-AE101 and ERM-AE103 a unique set of four isotope reference materials and three offset δ11B reference materials for boron isotope determination are now available from European Reference Materials.