Filtern
Dokumenttyp
- Vortrag (19)
- Zeitschriftenartikel (2)
- Posterpräsentation (2)
- Sonstiges (1)
- Forschungsbericht (1)
Referierte Publikation
- nein (25) (entfernen)
Schlagworte
- Traceability (25) (entfernen)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (19)
IRWG strategy update
(2022)
The calibration of isotope ratio measurements is an ongoing challenge since instrumental isotope fractionation (IIF) has been detected in mass spectrometry (MS). There is a variety of approaches which either bypass IIF such as delta measurements or refer to reference materials (RMs) and thus shifting the problem of calibration to somebody else: the RM producer. For certifying isotope RMs with absolute isotope ratios only a few approaches are available, namely the isotope mixture approach, the double spike approach, the mass bias regression model and total evaporation in TIMS. All of them require either enriched isotopes, isotope RMs of another element or an RM for correcting residual error. As the enriched isotopes required for the isotope mixture and the double spike approach need to be fully characterized beforehand, all mentioned calibration approaches require a standard.
Here, a new and standard-free calibration approach for obtaining absolute isotope ratios of multi-isotopic elements has been developed. The underlying principle is that each MS suffers from IIF and thus yields a specific isotope fractionation line in a three-isotope diagram. When applying a second MS featuring a different ionization mechanism, we obtain a second isotope fractionation line with a different slope in the same three-isotope diagram. In both cases the absolute isotope ratios range somewhere on the isotope fractionation line. Consequentially, the intersect of both lines yield the absolute isotope ratios of the measured sample. This theory has been tested by measuring Cd and Pb isotope ratios of suitable isotope RMs with a TIMS and an ICP-MS, both equipped with multi-collector array. During the measurements the ionization conditions were changed such that different extent of the isotope fractionation has been achieved. With the resulting data set the theory described above could be verified. The obtained absolute isotope ratios were metrologically compatible with the certified isotope ratios. The remaining average bias of -5 ‰ can be reduced with further improvements. The calibration approach is universal and can be applied to any multi-isotopic element and it is not limited by the type of the mass spectrometer.
Technologie-kritische Elemente (TCE) sind unentbehrliche Materialien für High-Tech Produkte wie Smartphones, Notebooks und Monitors. Ihr Bedarf wird voraussichtlich aufgrund des gesellschaftlichen Wandels hin zu einer grünen Ökonomie exponentiell ansteigen. Dieser Wandel wird vor allem auch durch erneuerbare Energien und Elektromobilität geprägt (European Green Deal). Diese Entwicklung in Verbindung mit einer nahezu fehlenden TCE Produktion in Europa setzt den Markt unter Druck und führt zu steigenden Preisen. Die Sicherung des TCE Nachschubs wurde in der gegenwärtigen Gesundheitskrise noch dringender und wurde daher auch zu einem der Hauptthemen des COVID-19 Recovery Plan, der eine Stärkung der europäischen Resilienz und Autonomie zum Ziel hat. Ein nachhaltige Lösung ist das Recycling der Abfall- bzw. Wertstoffe und letztendlich eine Circular Economy. Allerdings ist die Analyse von Abfallströmen schwierig und erfordert geeignete analytische Lösungen, die SI-rückführbare und somit vergleichbare Messergebnisse im gesamten Recyclingprozess ermöglichen. Die dafür erforderlichen, für TCE zertifizierte, Referenzmaterialien und nötige standardisierte Verfahren fehlen bisher nahezu vollständig. In diesem Beitrag werden die analytischen Herausforderungen, wie z.B. die extreme Heterogenität der Materialien, Schwierigkeiten beim Probenaufschluss und das Fehlen von Referenzmaterialien diskutiert. Und es wird das EMPIR-Projekt MetroCycleEU vorgestellt, dessen Ziel es ist Referenz- und Routineverfahren für ausgewählte TCE (Co, Ga, Ge, In, Ta, Nd, Pr, Dy, Gd, La, Au, Pt, Pd, Rh) zu entwickeln und Referenzmaterialien für Platinen, LEDs und Li-Batterien bereitzustellen.
Thirteen laboratories participated in an international interlaboratory comparison for the determination of 87Sr/86Sr isotope ratios in four cement reference materials (RM) using the conventional method for 87Sr/86Sr isotope ratios analyses. Sample dissolution and Sr isolation via ion exchange chromatography were required since the cement samples were distributed as powders. Analytical preparation included the use of various digestion methods including mixed mineral acids, microwave/acid, bomb/acid digestion or borate fusion, followed by Sr separation using ion exchange chromatography. In this study, we evaluated whether any statistically significant differences were attributable to instrumental differences (i.e., MC-ICP-MS and MC-TIMS), or to laboratory-specific techniques (different sample preparation techniques, Sr isolation and the procedures for correcting the data outputs). To evaluate these effects, consensus values for cement RMs and associated standard uncertainties were estimated by fitting a linear, Gaussian mixed effects model using the R function “lmer” defined in package “lme4”. No statistically significant effects (SSE) attributable to instrumental differences regardless of whether the materials are considered together or separately were evident. There were SSE attributable to differences between laboratories for three cement RMs when the individual cements were considered separately. Since consideration or disregard for such differences does not induce significant changes in the estimate of the consensus values for the 87Sr/86Sr isotope ratios in cement RMs, these effects can safely be neglected when calculating the best estimates for the true values of 87Sr/86Sr isotope ratios in these RMs.
Isotope reference materials
(2022)
The variation of isotope ratios is increasingly used to unravel natural and technical questions. In the past, the investigation and interpretation of such variations was the field of a limited number of experts. With new upcoming techniques and research topics in the last decades, such as provenance or food authenticity studies, the number of published isotope data strongly increased. Instrumental developments such as the enhancement of inductively coupled plasma mass spectrometers (ICP-MS) from an instrument for simple quantitative analysis to highly sophisticated isotope ratio machines influenced this process significantly. While in former times only experts in mass spectrometry were able to produce reliable isotope data, nowadays many laboratories, never been in touch with mass spectrometry before, produce isotope data with an ICP-MS. Isotope reference materials (iCRM) are indispensable to enable a reliable method validation or in rare cases even SI-traceability. The fast development and the broad availability of ICP-MS also lead to an expansion of the classical research areas and new elements are under investigation. Irrespective of the investigated element or the knowledge of the user all isotope ratio applications require reference materials either for correction of instrumental isotope fractionation, for method validation or to provide a common accepted basis as needed for delta measurements. This presentation will outline the basic principles and illustrate the urgent need for new iCRMs. Consequently, the production and certification of iCRMs will be discussed and illustrated by examples of already completed certification projects. Finally, plans for future iCRMs to be produced at BAM will be presented.
The need for quality assessment of anthropogenic impact on environmental pollution is increasing due to discharge from various industries, the use of chemicals in agriculture and the consumption of fossil fuels. Diminishing resources such as natural waters used for the cultivation of agricultural products, plant and animal habitats are under severe pollution pressure and are at constant risk. Several parameters, such as Pb, Cd, Ni, Hg were listed by Water Framework Directive in Directive(2008/105/EC) in the priority substances. Cadmium and Hg were identified as priority hazardous substances whereas As is an important contaminant for its potential toxicological and carcinogenic effects. An inter-comparison study is organised in EURAMET TC-MC in order to demonstrate the capability participants for measuring five elements in river water. The participants carried out measurements for analytes: Pb, Cd, Ni and As as mandatory elements, and Se as an optional one. Participants were asked to perform the measurements with respect to the protocol provided. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/.
The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Determination of absolute (SI‐traceable) isotope ratios: The use of Gravimetric Isotope Mixtures
(2023)
The presentation is brief overview on how to use gravimetric isotope mixtures to determine SI traceable isotope ratios. There is no mass spectrometer on earth that directly measures isotope ratios. Mass spectrometers will always measure signal intensity ratios instead. The actual problem is that the measured intensity ratios differ more or less from the isotope ratios. The difference can be up to more than 10 % in case of lithium while it‘s below 1 % in case of the heavier elements like lead or uranium. Consequently, the signal intensity ratios are expressed for example in V/V depending on the type of mass spectrometer you are using, while the isotope ratios are expressed in mol/mol. This phenomenon is called Instrumental Isotopic Fractionation (or short IIF) but the more common name is still mass bias (even though this name is not entirely correct). To convert the measured into the isotope ratio usually a simple multiplication with a so-called correction (or short K) factor is done. Therefore, the problem is to determine the K factor. In absence of isotope reference materials the golden route is via gravimetric isotope mixtures, which will be explained within the presentation.