Knowledge about feeding behavior is essential to determine trophic interactions and reconstruct predator-prey relationships in modern and past foodwebs. Traditionally, nitrogen isotopes (δ15N) of collagen are used to quantify the ingestion of animal protein, however collagen usually does not preserve over geological time scales. To infer the diet of extinct vertebrates from fossil material more resistant dietary proxies such as Ca and Mg isotopes are needed, which are major elements in the bioapatite of bones and teeth. Magnesium is a bio-essential element that replaces calcium in the bioapatite lattice and bone and enamel δ26Mg values of extant mammals increase systematically along the foodchain [1, 2].
The existing δ26Mg data, however, is scarce, in particular with respect to carnivores, thus still limiting the capability of this dietary proxy to reliably determine trophic differences between plant- and animal-feeders. To better constrain trophic-level effects recorded in Mg isotopes, we analyzed δ26Mg of bioapatite from modern mammals with a focus on faunivores, both carnivores and as yet unexplored insectivores.
The trophic level effect of δ26Mg is influenced by the geological substrate which causes isotope variability in δ26Mg of faunal remains between different ecosystems [1, 2]. Therefore, as first-order proxy for sample provenance and to assess potential influences of the bedrock substrate of the animals´ habitats on δ26Mg of bones and teeth, we measured the 87Sr/86Sr on the same specimens. This information will enable us to refine trophic level effects and determine whether δ26Mg can be used to distinguish different faunivores isotopically. This will be of paramount importance for dietary reconstructions of trophic niches in fossil foodwebs.
[1] Martin et al. (2014) Geochmica Cosmochimica Acta 130, 12-20. [2] Martin et al. (2015) Proceedings of the National Academy of Sciences 112, 430-435.
In the past, δ26/24Mg measurements were referenced to NIST SRM 980, the initial zero of the δ26/24Mg scale. With the development of MC-ICPMS, the detection of small but measurable isotopic differences in different chips of SRM 980 became apparent. To solve this problem a suite of magnesium isotope reference materials, ERM-AE143, -AE144 and -AE145, has been certified in a first study by applying an ab initio calibration for absolute Mg isotope ratios without any a priori assumptions, a procedure which fulfils all requirements of a primary method of measurement. We could achieve for the first time measurement uncertainties for isotope amount ratios close to the typical precision of magnesium delta values, δ26/24Mg, which are at the 0.1 ‰ level (2SD). In addition, it was demonstrated that commonly used fractionation laws are invalid for correcting Mg isotope ratios in multi-collector ICPMS as they result in a bias which is not covered by its associated uncertainty. Depending on their type, fractionation laws create a bias up to several per mil, with the exponential law showing the smallest bias between 0.1 ‰ to 0.7 ‰.
With these isotope reference materials, it is possible to establish SI-traceability for magnesium delta measurements. To realize this, we organized a second study within which five expert laboratories participated to cross-calibrate all available magnesium isotope standards, which are NIST SRM 980, IRMM-009, ERM-AE143, ERM-AE144, ERM-AE145 and the standards DSM3 and Cambridge-1. The mean δ26/24Mg values for the individual iRMs, calculated from the laboratory means show 2 SD reproducibilities varying between 0.025 and 0.093 ‰. Propagated measurement uncertainties suggest a standard uncertainty of about 0.1‰ for δ26/24Mg determinations (2SD). Thus, SI traceability for magnesium isotope amount ratios and delta values is demonstrated to be established.
In the past, δ26/24Mg measurements were referenced to NIST SRM 980, the initial zero of the δ26/24Mg scale. With the development of MC-ICPMS, the detection of small but measurable isotopic differences in different chips of SRM 980 became apparent. To solve this problem a suite of magnesium isotope reference materials, ERM-AE143, -AE144 and -AE145, has been certified in a first study by applying an ab initio calibration for absolute Mg isotope ratios without any a priori assumptions, a procedure which fulfils all requirements of a primary method of measurement. We could achieve for the first time measurement uncertainties for isotope amount ratios close to the typical precision of magnesium delta values, δ26/24Mg, which are at the 0.1 ‰ level (2SD). In addition, it was demonstrated that commonly used fractionation laws are invalid for correcting Mg isotope ratios in multi-collector ICPMS as they result in a bias which is not covered by its associated uncertainty. Depending on their type, fractionation laws create a bias up to several per mil, with the exponential law showing the smallest bias between 0.1 ‰ to 0.7 ‰.
With these isotope reference materials, it is possible to establish SI-traceability for magnesium delta measurements. To realize this, we organized a second study within which five expert laboratories participated to cross-calibrate all available magnesium isotope standards, which are NIST SRM 980, IRMM-009, ERM-AE143, ERM-AE144, ERM-AE145 and the standards DSM3 and Cambridge-1. The mean δ26/24Mg values for the individual iRMs, calculated from the laboratory means show 2 SD reproducibilities varying between 0.025 and 0.093 ‰. Propagated measurement uncertainties suggest a standard uncertainty of about 0.1‰ for δ26/24Mg determinations (2SD). Thus, SI traceability for magnesium isotope amount ratios and delta values is demonstrated to be established.