Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (19)
- Zeitschriftenartikel (10)
- Posterpräsentation (3)
Schlagworte
- Metrology (32) (entfernen)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (19)
The calibration of isotope ratio measurements is an ongoing challenge since instrumental isotope fractionation (IIF) has been detected in mass spectrometry (MS). There is a variety of approaches which either bypass IIF such as delta measurements or refer to reference materials (RMs) and thus shifting the problem of calibration to somebody else: the RM producer. For certifying isotope RMs with absolute isotope ratios only a few approaches are available, namely the isotope mixture approach, the double spike approach, the mass bias regression model and total evaporation in TIMS. All of them require either enriched isotopes, isotope RMs of another element or an RM for correcting residual error. As the enriched isotopes required for the isotope mixture and the double spike approach need to be fully characterized beforehand, all mentioned calibration approaches require a standard.
Here, a new and standard-free calibration approach for obtaining absolute isotope ratios of multi-isotopic elements has been developed. The underlying principle is that each MS suffers from IIF and thus yields a specific isotope fractionation line in a three-isotope diagram. When applying a second MS featuring a different ionization mechanism, we obtain a second isotope fractionation line with a different slope in the same three-isotope diagram. In both cases the absolute isotope ratios range somewhere on the isotope fractionation line. Consequentially, the intersect of both lines yield the absolute isotope ratios of the measured sample. This theory has been tested by measuring Cd and Pb isotope ratios of suitable isotope RMs with a TIMS and an ICP-MS, both equipped with multi-collector array. During the measurements the ionization conditions were changed such that different extent of the isotope fractionation has been achieved. With the resulting data set the theory described above could be verified. The obtained absolute isotope ratios were metrologically compatible with the certified isotope ratios. The remaining average bias of -5 ‰ can be reduced with further improvements. The calibration approach is universal and can be applied to any multi-isotopic element and it is not limited by the type of the mass spectrometer.
ICP-MS has played a key role in inorganic chemical metrology for 25 years, from the 1993 CIPM feasibility study which led to establishment of the CCQM. Since that time, the Inorganic Analysis Working Group of the CCQM has organised 56 international comparisons involving measurements by ICP-MS and, in a recent comparison, 16 different national institutes submitted their results using the technique. Metrological applications of ICP-MS currently address an enormous range of measurements using a wide variety of instrumentation, calibration strategies and methodologies. This review provides an overview of the ICP-MS field with an emphasis on developments which are of particular relevance to chemical metrology.
Examples from CCQM comparisons and the services available from the participants are used to illustrate how the capability and scope of ICP-MS methods have expanded far beyond the expectations of 1993. This is due in part to the research and development Programmes of the national institutes which participate in the CCQM. They have played a key role in advancing new instrumentation and applications for elemental analysis, isotope dilution mass spectrometry, determination of isotopic ratio or composition, and speciation of organometallic compounds. These developments are continuing today, as demonstrated by work in new fields such as heteroatom quantitation of proteins, characterisation and counting of nanoparticles using spICP-MS, and LA-ICP-MS analysis of solid materials.
High purity materials can serve as a realisation of the Système International d’Unitès (SI) unit amount of substance for the specific element. Solutions prepared from such high purity materials using gravimetric preparation and the concept of molar mass are used as calibration solutions in many fields of analytical chemistry. Calibration solutions prepared this way provide the traceability to the SI and are the metrological basis in elemental analysis.
The preparation and characterization of such primary pure substances, representing the realisation of the SI unit amount of substance, is undertaken only by a small number of National Metrology Institutes (NMI) and Designated Institutes (DI).
Many other NMIs and DIs, however, prepare elemental calibration solutions as calibrants for their measurement services, such as the certification of matrix Reference Materials or the provision of reference values for Proficiency Testing schemes. The elemental calibration solutions used for this purpose are not a direct service to customers, such as preparing secondary calibration solutions, but provide the source of traceability for the other services. Hence, it is necessary for the NMI or DI to obtain data on the purity of the pure metals or other materials used to prepare the solutions with measurement uncertainties meeting the needs of the above described services. This is commonly undertaken as a “fit for purpose” assessment, appropriate for the uncertainty requirement of the service provided to customers.
As a consequence, total purity measurements are a long-term strategy of CCQM-IAWG. Several studies were conducted (CCQM-P107, CCQM-K72 and CCQM-P149) on the measurement of the purity of zinc. From these studies, several conclusions can be drawn for the purity assessment of a pure (metallic) element. These conclusions will be put together in this document in order to assist all NMIs/DIs in performing a purity assessment, whenever needed.
The reference method for obtaining absolute isotope ratios still is the isotope mixture approach. Due the huge efforts required the full isotope mixture approach is applied only by a few institutes worldwide. To enable an IRWG key comparison with a sufficiently large number of participants a proposal for absolute cu isotope ratios is presented where participants will be provided with the enriched isotopes, the isotope mixtures and the samples. In parallel a pilot study will be organized where alternative approaches for obtaining absolute Cu isotope ratios can be applied.
The presentations gives a short introduction into isotope analysis illustrated by examples from archaeology, food provenancing and metrology. In the main part current projects on the provenance determination of cement, the intercalibration of Mg isotope reference materials and the development of a new calibration approach for isotope measurements are presented.
Technology critical elements (TCE) are key materials for high-tech products such as smartphones, notebooks and monitors. Their demand is expected to increase exponentially as a result of the shift towards greener economy through the deployment of renewable energy and electro mobility solutions (European Green Deal). This and the lack of natural resources in the EU, puts the market under pressure and leads to increasing prices. The need to secure TCE supply has become even more pressing under the current health crisis and it is a major objective of the Covid-19 Recovery Plan aimed at reinforcing Europe’s resilience and autonomy. A sustainable solution for solving this problem is first through recycling and finally through a circular economy. However, the analysis of waste streams is a complicating factor and requires suitable analytical solutions first, which need to be traceable to the SI to allow for comparability of measurement results throughout the recycling process or the circular economy. The required reference materials certified for TCE in the corresponding waste or secondary raw materials and specific documentary standards for TCE to comply with ISO/IEC 17025 requirements, however, are lacking. Furthermore, wastes from the urban mine are extremely heterogeneous, which makes the estimation of their TCE content difficult. Currently there is a lack of knowledge at the European level about the TCE stocks and flows in the urban mine. Given the high volume of waste generated and received, fast reliable analytical methods as well as sampling and sample preparation strategies are needed to determine the economic value of the waste and of the final product and to develop recycling procedures. Within this project we focus on a set of TCEs(Co, Ga, Ge, In, Ta, Nd, Pr, Dy, Gd, La, Au, Pt, Pd, Rh), which have been selected from the list of critical elements for Europe established by the EU in 2017. The overall objective of the project is to provide reliable and SI traceable determination of TCE in urban waste material at µg/g levels in order to increase the efficiency and accuracy of TCE recycling. This will be realized by developing validated SI-traceable reference methods, developing traceable and validated reference materials for the TCEs, validating the use of the routine methods and reference materials for real world applications and facilitating the take up of the technology and measurement infrastructure developed in the project by the measurement supply chain, standards developing organisations and end users.
Technology critical elements (TCE) are key materials for high-tech products such as smartphones, notebooks and monitors. Their demand is expected to increase exponentially due to the shift towards greener economy through the deployment of renewable energy and electro mobility solutions (European Green Deal). This and the lack of TCE production within the EU, puts the market under pressure and leads to increasing prices. The need to secure TCE supply has become even more pressing under the current health crisis and it is a major objective of the Covid-19 Recovery Plan aimed at reinforcing Europe’s resilience and autonomy. A sustainable solution is effective recycling and finally a circular economy. However, the analysis of waste streams is difficult and requires suitable SI traceable analytical solutions to allow for comparability of measurement results throughout the recycling process. The required reference materials (RMs) certified for TCE in the corresponding waste or secondary raw materials and specific documentary standards for TCE to comply with ISO/IEC 17025 requirements, however, are lacking. Furthermore, waste from the so-called “urban mine” is extremely heterogeneous making the estimation of its TCE content difficult. Currently, there is a lack of knowledge at the European level about the TCE stocks and flows in the urban mine. Given the high volume of waste generated and received, fast reliable analytical methods as well as sampling and sample preparation strategies are needed to determine the economic value of the waste and of the final product and to develop and improve recycling procedures.
Within this project we focus on TCEs (Co, Ga, Ge, In, Ta, Nd, Pr, Dy, Gd, La, Au, Pt, Pd, Rh), which have been selected from the list of critical elements for Europe established by the EU in 2020. The overall objective of the project is to provide the reliable and SI traceable determination of TCE in urban waste material at µg/g levels to increase the efficiency and accuracy of TCE recycling. This will be realized by developing validated SI-traceable reference methods, developing traceable and validated RMs for the TCEs, validating the use of the routine methods and RMs for real world applications and facilitating the take up of the technology and measurement infrastructure developed in the project by the measurement supply chain, standards developing organizations and end users.
This presentation will give an overview of the consortium, the project structure and the planned research. First activities will be presented as well.
This presentation provides a short introduction to the Commission on Isotopic Abundances and Atomic Weights (CIAAW). It describes the role of the Commission and provides an insight into its work and the corresponding principal tasks. Finally, it provides the reader with the latest achievements and with the most recent publications.
Introduction: The influence of copper, iron and zinc concentrations on the formation of ß-amyloid plaques and neurofibrillary tangles in Alzheimer’s disease (AD) is widely discussed in the community. The results from human and animal studies so far are mixed with some studies showing a correlation and others not. From a number of studies, it is known that disease state and isotopic composition of essential elements can be coupled.
Aim: The aim of the study was to identify changes in element content and isotopic composition in two transgenic mouse models used in AD research compared to their genetic WT relatives and to establish whether element content and isotopic signature between different laboratories is comparable.
Methods: ß-amyloid (5xFAD) and tau overexpressing (L66) mice together with their matching wild-types were bred at dedicated facilities in accordance with the European Communities Council Directive (63/2010/EU). Serum and brain were sampled after sacrifice and the samples distributed among the participants of the study. The tissues were acid digested for total element determination and high-precision isotope ratio determination. Element content was determined by either sector-field or quadrupole-based inductively coupled plasma mass spectrometry (ICPMS). For the determination of isotope ratios multi-collector ICPMS was used.
Results: Total copper content was significantly higher for L66 and their matched WT compared to 5xFAD and WT. Brains of L66 mice contained more Fe in brain than their WT, Zn and Cu were not significantly different between L66 and WT. Whereas 5xFAD mice had a slightly lower Cu and slightly higher Zn concentration in brain compared to WT. The isotopic signature in brain of L66 mice for Fe was different from their controls, whereas Zn isotope ratios were influenced in 5xFAD mice compared to their WT. The Cu isotopic ratio did not seem to be influenced in either strain. In serum, the shifts were less pronounced.
Conclusion: Even though neither Tau-protein nor amyloid precursor protein are known to be metal-dependent / -containing proteins, the overexpression of both influences the Fe, Cu and Zn metabolism in brain and to some extent also in serum as can be seen not only using total element determination but probably more clearly studying the isotopic signature of Fe, Cu and Zn.