Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (116)
- Zeitschriftenartikel (96)
- Posterpräsentation (25)
- Forschungsbericht (11)
- Beitrag zu einem Sammelband (9)
- Beitrag zu einem Tagungsband (7)
- Buchkapitel (3)
- Sonstiges (2)
- Forschungsdatensatz (1)
Schlagworte
- Traceability (34)
- Metrology (32)
- IDMS (19)
- Absolute isotope ratio (18)
- Isotope ratio (17)
- Uncertainty (16)
- CCQM (11)
- Measurement uncertainty (11)
- ICP-MS (10)
- Reference material (10)
- TIMS (10)
- Delta value (9)
- ICPMS (8)
- Isotope reference materials (8)
- Mass spectrometry (8)
- Copper (7)
- Reference materials (7)
- Cement (6)
- Comparability (6)
- Isotope fractionation (6)
- Isotope reference material (6)
- Metrology in chemistry (6)
- Atomic weight (5)
- Conventional isotope ratio (5)
- Delta reference materials (5)
- Herkunft (5)
- Isotope amount ratio (5)
- Isotope dilution (5)
- Magnesium (5)
- Purity (5)
- Sulfur (5)
- Triple isotope fractionation (5)
- Boron isotopes (4)
- Cadmium (4)
- Certification (4)
- Delta scale (4)
- Human serum (4)
- Interlaboratory comparison (4)
- Isotope (4)
- Isotope delta value (4)
- Isotope dilution mass spectrometry (4)
- Isotope ratios (4)
- Lead (4)
- MC-ICP-MS (4)
- Molar mass (4)
- Provenance (4)
- Purity assessment (4)
- SI traceability (4)
- Stable isotopes (4)
- Zinc (4)
- Archaeometry (3)
- Boron isotope variations (3)
- Delta values (3)
- Delta-scale (3)
- Iron (3)
- Isotopes (3)
- Lead isotopes (3)
- Palladium (3)
- Platinum (3)
- Synthetic isotope mixtures (3)
- Automotive exhaust emissions (2)
- Biodiesel (2)
- Biodiesel fuel (2)
- Bor (2)
- Boron (2)
- Boron isotope fractionation (2)
- CMC (2)
- Calibration (2)
- Circular economy (2)
- Geochemistry (2)
- Geological material (2)
- IRM (2)
- Isotope Dilution (2)
- Isotope delta (2)
- Isotopenverhältnisse (2)
- Lithium (2)
- Magnesium isotope ratios (2)
- Milk (2)
- Provenance studies (2)
- SI (2)
- SI-traceability (2)
- Silicon (2)
- Sr isotopes (2)
- Surface analysis (2)
- TCE (2)
- Tetramethylammonium hydroxide (2)
- Transferrin (2)
- Uncertainty budget (2)
- boron (2)
- metrology (2)
- traceability (2)
- 87Sr/86Sr (1)
- AAS (1)
- Absolute Isotopenverhältnisse (1)
- Absolute isotope abundance (1)
- Algorithms (1)
- Alzheimer disease (1)
- Alzheimer’s disease (1)
- Amyloid-beta (1)
- Analyte-matrix separation (1)
- Analytical Chemistry (1)
- Analytical uncertainty (1)
- Antikensammlung Berlin (1)
- App (1)
- Archaeology (1)
- Archäometrie (1)
- Areal density (1)
- Argon (1)
- Ash content (1)
- Atomic Absorption Spectrometry (1)
- Atomic absorption spectrometry (1)
- Atomic weights (1)
- Authenticity (1)
- Automotive pollution (1)
- Avogadro constant (1)
- Bell (1)
- Bell pepper (1)
- Bioapatite (1)
- Biogenic carbonates (1)
- Biological boron recycling (1)
- Blank characterization (1)
- Blei (1)
- Blei-Isotopie (1)
- Bodenanalyse (1)
- Boron isotope (1)
- Boron isotopes in food (1)
- Boron isotopic composition (1)
- Boron monohydride (1)
- Boron transport (1)
- Brain (1)
- Branching ratio (1)
- Brassica napus (1)
- CCQM-P107 (1)
- CE/MC-ICP-MS (1)
- CRM (1)
- Calcification (1)
- Calcium (1)
- Catalytic converters (1)
- Cationic exchange (1)
- Cattle (1)
- Cconventional method (1)
- Cd mass fraction (1)
- Central Taurus (1)
- Cheese (1)
- Chenopodium album (1)
- Chromium (1)
- Ciaaw.org (1)
- Classical oven-drying (1)
- Classical primary measurement method (CPM) (1)
- Commercial moisture analyzer (1)
- Comparison (1)
- Conventional isotope ratios (1)
- Conventional method (1)
- Counting detector (1)
- Cross sections (1)
- Cu-64 (1)
- Curse tablets (1)
- Dairy cows (1)
- Data processing (1)
- Dead time (1)
- Degree of equivalence (1)
- Delta isotope standard (1)
- Delta notation (1)
- Delta-RM (1)
- Dementia (1)
- Detector deadtime (1)
- Determination of metrology of new cadmium atomic weight (1)
- Development (1)
- Diagenesis (1)
- Direct metal assay (1)
- Dissolution (1)
- Double IDMS (1)
- Double isotope dilution (1)
- Dual mode detector (1)
- EPMA (1)
- ERM (1)
- EURAMET (1)
- Elemental composition (1)
- Elemental fingerprints (1)
- Elemental mass spectrometry (1)
- Elementanalyse (1)
- Emissionen (1)
- Enriched isotope (1)
- Erythrocytes (1)
- Faecal monitoring (1)
- Feed (1)
- Feeding regime (1)
- Finow Canal (1)
- Fluchtafel (1)
- Food (1)
- Fossil fuel (1)
- Fuel (1)
- Fundamental science (1)
- GDMS (1)
- Graphite furnace (1)
- Gravimtric isotope mixtures (1)
- Greek curse tablets (1)
- Green Deal (1)
- Gypsum (1)
- HR-CS-MAS (1)
- Hafnium (1)
- Heavy metals (1)
- High purity metals (1)
- High-fired gypsum mortar (1)
- High-purity elements (1)
- High-resolution continuum source absorption spectrometry (1)
- High-resolution continuum source graphite furnace atomic absorption spectrometry (1)
- Hydrothermal fluid (1)
- Hyphenated (1)
- ICP-OES (1)
- ICP-TOFMS (1)
- ICP-ToF-MS (1)
- ID-ICP-MS (1)
- ID-MS (1)
- ILC (1)
- IMEP-9 (1)
- IUPAC Inorganic chemistry division (1)
- Iinductively coupled plasma mass spectrometry (1)
- Impurities (1)
- Impurity assessment (1)
- Impurity assessment approach (1)
- In-house calibration solution (1)
- Inductively coupled plasma (ICP) mass spectrometry (1)
- Inorganic chemical analysis (1)
- Inorganic impurities (1)
- Instrumental isotope fractionation (1)
- Interferences (1)
- Intra-plant isotope variability (1)
- Iridium (1)
- Iron isotope fractionation (1)
- Isobaric interferences (1)
- Isotope abundance (1)
- Isotope amount ratios (1)
- Isotope mixture (1)
- Isotope mixtures (1)
- Isotope purification (1)
- Isotope ratio mass spectrometry (1)
- Isotopenverhältnisse Strontium und Blei (1)
- Isotopenzusammensetzung (1)
- Isotopic Reference Material (1)
- Isotopic abundance variations (1)
- Isotopic analysis (1)
- Isotopic composition (1)
- Isotopic fractionation (1)
- Kalke (1)
- Karl Fischer titration (1)
- Kernkraftwerk (1)
- Kernkraftwerke (1)
- Kilogram (1)
- Königswasserextraktion (1)
- LA-(MC-)ICP-MS (1)
- LA-ICP-MS (1)
- LSVEC (1)
- Lagerstätten (1)
- Laser ablation (1)
- Lead isotope composition (1)
- Lead isotope ratios (1)
- Lead isotope variations (1)
- Lead isotopic composition (1)
- Legacy pollution (1)
- Low sulfur (1)
- MC-TIMS (1)
- MDG (1)
- MW-AES (1)
- Machine learning (1)
- Magnesium absorption (1)
- Magnesium stable isotopes (1)
- Mangesium (1)
- Mass discrimination (1)
- Mass fractionation (1)
- Massenspektrometrie (1)
- Matrix samples (1)
- Matrix separation (1)
- Measurement space (1)
- Measuremment uncertainty (1)
- Memory effect (1)
- Mercury (1)
- Mercury speciation (1)
- Metal assay approach (1)
- Metal sublimation (1)
- Methylmercury (1)
- Metrology in Chemistry (1)
- Micro-sublimation (1)
- Microbially induced corrosion (1)
- Mittelalterliche Pilgerzeichen (1)
- Moisture (1)
- Mole (1)
- Molecular absorption (1)
- Multi-collector ICP-MS (1)
- Multi-collector inductively coupled plasma-mass spectrometry (ICP-MS) (1)
- Multi-element screening (1)
- Multicollector inductively coupled plasma mass spectrometry (1)
- NTD (1)
- Nanoparticles (1)
- Neutron activation (1)
- Neutron transmutation doping (1)
- Nickel (1)
- Nitrogen microwave inductively coupled atmospheric pressure mass spectrometry (1)
- Noise (1)
- Non-metal analysis (1)
- Open vessel digestion (1)
- Optimization (1)
- Ore provenance (1)
- PERM (1)
- PGE (1)
- PTI-MS (1)
- Pb isotope ratio thermal ionization mass spectrometry (1)
- Pb isotopes (1)
- Pepper (1)
- Petrol (1)
- Plant metabolism (1)
- Plant tissue (1)
- Plants (1)
- Platinum group elements (PGE) (1)
- Polarised light microscopy (1)
- Polyethylene (1)
- Polypropylene (1)
- Pore fluids (1)
- Portland cement (1)
- Portland clinker (1)
- Priam's treasure (1)
- Primary Isotopic Reference Material (1)
- Primary calibration solution (1)
- Primary difference measurement method (PDM) (1)
- Primary method of measurement (1)
- Primary transfer standards (PTSs) (1)
- Primäres Isotopenreferenzmaterial (1)
- Provenancing (1)
- Purity analysis (1)
- Purity determination (1)
- Quality system (1)
- Quantitative protein analysis (1)
- Radiogenic isotopes (1)
- Raman microspectroscopy (1)
- Raman spectroscopy (1)
- Re-evaluation (1)
- Reference data (1)
- Reference measurement (1)
- Reference measurement procedures (1)
- Reference measurements (1)
- Reference procedure (1)
- Review (1)
- Revision of the SI (1)
- River water (1)
- SF-ICP-MS (1)
- Sample-sample bracketing (1)
- Scale anchor (1)
- Scale conversion (1)
- Schwermetallbestimmung (1)
- Selenium (1)
- Serum (1)
- Silver artefacts (1)
- Single IDMS (1)
- Single Particle (1)
- Soil (1)
- Soil available boron (1)
- Spike (1)
- Sr and Nd isotope analysis (1)
- Sr isotope analysis (1)
- Stable isotope (1)
- Standard addition (1)
- Standard atomic weight (1)
- Statistical analysis (1)
- Strontium isotope (1)
- Strontium isotope ratio (1)
- Sulfur in oil (1)
- Sulphur (1)
- Sulphur isotope (1)
- Synthetic mixtures (1)
- TIMs (1)
- Tau (1)
- Technology-critical elements (1)
- Terminology (1)
- Thermal ionization mass spectrometry (1)
- Thermionenmassenspektrometrie (1)
- Thermogravimetry (1)
- Total element determination (1)
- Toxic elements (1)
- Transient signal (1)
- Triple IDMS (1)
- Trojan silver artefacts (1)
- Trophic level (1)
- Unsicherheitsvergleiche (1)
- Uranium (1)
- Urinary monitoring (1)
- Urine (1)
- Validate method (1)
- Value assignment (1)
- WD-XRF (1)
- Water (1)
- Wet digestion (1)
- Wood chips (1)
- XRCD method (1)
- Ytterbium (1)
- absolute measurements (1)
- atomic weight (1)
- bell pepper (1)
- collision cell (1)
- delta value (1)
- enriched isotope (1)
- interferences (1)
- isotope fractionation (1)
- isotope ratio (1)
- isotope reference material (1)
- key comparison (1)
- lank characterization (1)
- magnesium (1)
- mass spectrometry (1)
- measurement uncertainty (1)
- metabolism (1)
- multi-collector (1)
- purity (1)
- reference material (1)
- silicon (1)
- species-specific isotope information (1)
- tandard addition (1)
- uncertainty budget (1)
- Ägyptisches Museum Berlin (1)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (87)
- 1.1 Anorganische Spurenanalytik (86)
- 1.3 Instrumentelle Analytik (3)
- 1.4 Prozessanalytik (3)
- 1.6 Anorganische Referenzmaterialien (3)
- P Präsident (3)
- P.0 Präsident und andere (3)
- S Qualitätsinfrastruktur (3)
- S.1 Qualität im Prüfwesen (3)
- 1.7 Organische Spuren- und Lebensmittelanalytik (2)
Eingeladener Vortrag
- nein (116)
Boron isotope amount ratios n(10B)/n(11B) have been determined by monitoring the absorption spectrum of boron monohydride (BH) in a graphite furnace using high-resolution continuum source molecular absorption spectrometry (HR-CS-MAS). Bands (0→0) and (1→1) for the electronic transition X1Σ+ → A1Π were evaluated around wavelengths 433.1 nm and 437.1 nm respectively. Clean and free of memory effect molecular spectra of BH were recorded. In order to eliminate the memory effect of boron, a combination of 2% (v/v) hydrogen gas in argon and 1% trifluoromethane in argon, an acid solution of calcium chloride and mannitol as chemical modifiers was used. Partial least square regression (PLS) for analysis of samples and reference materials were applied. For this, a spectral library with different isotopes ratios for PLS regression was built. Results obtained around the 433.1 nm and 437.1 nm spectral regions are metrologically compatible with those reported by mass spectrometric methods. Moreover, for the evaluated region of 437 nm, an accuracy of 0.15‰ is obtained as the average deviation from the isotope reference materials. Expanded uncertainties with a coverage factor of k = 2 range between 0.15 and 0.44‰. This accuracy and precision are compatible with those obtained by mass spectrometry for boron isotope ratio measurements.
Three petrol reference materials were certified for their total sulfur content in support of Directive 2003/17/EC of the European Parliament and of the European Council, which stipulates that petrol with a maximum S content of 10 mg/kg must be available in all member states by 2009. Commercially available petrol was obtained and filled into borosilicate ampoules without further treatment. Homogeneity of the materials was tested and no heterogeneity was detected for two of the materials, whereas minor heterogeneity was observed for the third material. Stability of the materials was tested for 8-12 months at 60 °C and no degradation was observed. Characterisation was based on isotope-dilution mass spectrometry (IDMS) applied as primary method of measurement by three European metrology institutes and certified values were assigned using all results. The certified uncertainties include contributions of (potential) heterogeneity, potential degradation as well as characterisation. The final assigned values are:
ERM-EF211: 48.8 ± 1.7 mg/kg
ERM-EF212: 20.2 ± 1.1 mg/kg
ERM-EF213: 9.1 ± 0.8 mg/kg
The materials are available from IRMM (ERM-EF211), LGC (ERM-EF212) and BAM (ERMEF213)
Assessment of international reference materials for isotope-ratio analysis (IUPAC Technical report)
(2014)
A new method combining isotope dilution mass spectrometry (IDMS) and standard addition has been developed to determine the mass fractions w of different elements in complex matrices: (a) silicon in aqueous tetramethylammonium hydroxide (TMAH), (b) sulfur in biodiesel fuel, and (c) iron bound to transferrin in human serum. All measurements were carried out using inductively coupled plasma mass spectrometry (ICP–MS). The method requires the gravimetric preparation of several blends (bi)—each consisting of roughly the same masses (mx,i) of the sample solution (x) and my,i of a spike solution (y) plus different masses (mz,i) of a reference solution (z).
Only these masses and the isotope ratios (Rb,i) in the blends and reference and spike solutions have to be measured. The derivation of the underlying equations based on linear regression is presented and compared to a related concept reported by Pagliano and Meija. The uncertainties achievable, e.g., in the case of the Si blank in extremely pure TMAH of urel (w(Si)) = 90% (linear regression method, this work) and urel (w(Si)) = 150% (the method reported by Pagliano and Meija) seem to suggest better applicability of the new method in practical use due to the higher robustness of regression analysis.
A new method combining isotope dilution mass spectrometry (IDMS) and standard addition has been developed to determine the mass fractions w of different elements in complex matrices: (a) silicon in aqueous tetramethylammonium hydroxide (TMAH), (b) sulfur in biodiesel fuel, and (c) iron bound to transferrin in human serum. All measurements were carried out using inductively coupled plasma mass spectrometry (ICP–MS). The method requires the gravimetric preparation of several blends (bi)—each consisting of roughly the same masses (mx,i) of the sample solution (x) and my,i of a spike solution (y) plus different masses (mz,i) of a reference solution (z).
Only these masses and the isotope ratios (Rb,i) in the blends and reference and spike solutions have to be measured. The derivation of the underlying equations based on linear regression is presented and compared to a related concept reported by Pagliano and Meija. The uncertainties achievable, e.g., in the case of the Si blank in extremely pure TMAH of urel (w(Si)) = 90% (linear regression method, this work) and urel (w(Si)) = 150% (the method reported by Pagliano and Meija) seem to suggest better applicability of the new method in practical use due to the higher robustness of regression analysis.
Thermal ionisation, also known as surface ionisation, was one of the first ionisation techniques developed for mass spectrometry, having been invented as early as 1918. The ionization process, described by the empirically derived “fractionation laws”, is widely understood. Isotope ratio measurements can be achieved with high precision and accuracy. Due to this, thermal ionisation has paved the way for great scientific achievements including: the discovery of new isotopes, the determination of radioactive half-lives and atomic weights of the elements, the accurate determination of the age of the earth and investigations on human society in the past such as mobility and trade. TIMS is still regarded as ‘golden standard’ in isotope ratio measurements. Thus the method is a reference technique that remains at the forefront of isotopic analysis particularly in the fields of metrology. A concise overview is given here of the technical background of thermal ionisation as well as the numerous applications of this technique in earth sciences, industry, metrology, and nuclear forensics.
The need for quality assessment of anthropogenic impact on environmental pollution is increasing due to discharge from various industries, the use of chemicals in agriculture and the consumption of fossil fuels. Diminishing resources such as natural waters used for the cultivation of agricultural products, plant and animal habitats are under severe pollution pressure and are at constant risk. Several parameters, such as Pb, Cd, Ni, Hg were listed by Water Framework Directive in Directive(2008/105/EC) in the priority substances. Cadmium and Hg were identified as priority hazardous substances whereas As is an important contaminant for its potential toxicological and carcinogenic effects. An inter-comparison study is organised in EURAMET TC-MC in order to demonstrate the capability participants for measuring five elements in river water. The participants carried out measurements for analytes: Pb, Cd, Ni and As as mandatory elements, and Se as an optional one. Participants were asked to perform the measurements with respect to the protocol provided. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/.
The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
In the interest of exploring their potential in the field of single particle analysis, a Microdroplet Generator (MDG) was coupled to an ICP-ToF-MS. Isotopic Dilution Analysis was also incorporated for the size determination of three different Platinum nanoparticles samples (50, 63 and 70 nm). The performance of the technique was validated by comparison to traditional size characterization techniques (sp-ICP-ToF-MS, TEM), while the robustness of the technique was proven by incorporating NaCl in the samples’ matrix, up to 100 mg/L.
The present Table of Standard Atomic Weights (TSAW) of the elements is perhaps one of the most familiar data sets in science. Unlike most parameters in physical science whose values and uncertainties are evaluated using the “Guide to the Expression of Uncertainty in Measurement” (GUM), the majority of standard atomic weight values and their uncertainties are consensus values, not GUM-evaluated values. The Commission on Isotopic Abundances and Atomic Weights of the International Union of Pure and Applied Chemistry (IUPAC) regularly evaluates the literature for new isotopic-abundance measurements that can lead to revised standard atomic-weight values, Ar(E) for element E.
The Commission strives to provide utmost clarity in products it disseminates, namely the TSAW and the Table of Isotopic Compositions of the Elements (TICE). In 2016, the Commission recognized that a guideline recommending the expression of uncertainty listed in parentheses following the standard atomic-weight value, for example, Ar(Se) = 78.971(8), did not agree with the GUM, which suggests that this parenthetic notation be reserved to express standard uncertainty, not the expanded uncertainty used in the TSAW and TICE. In 2017, to eliminate this noncompliance with the GUM, a new format was adopted in which the uncertainty value is specified by the “±” symbol, for example, Ar(Se) = 78.971 ± 0.008. To clarify the definition of uncertainty, a new footnote has been added to the TSAW. This footnote emphasizes that an atomic-weight uncertainty is a consensus (decisional) uncertainty. Not only has the Commission shielded users of the TSAW and TICE from unreliable measurements that appear in the literature as a result of unduly small uncertainties, but the aim of IUPAC has been fulfilled by which any scientist, taking any natural sample from commerce or research, can expect the sample atomic weight to lie within Ar(E) ± its uncertainty almost all of the time.