Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (116)
- Zeitschriftenartikel (98)
- Posterpräsentation (25)
- Forschungsbericht (11)
- Beitrag zu einem Sammelband (9)
- Beitrag zu einem Tagungsband (7)
- Buchkapitel (3)
- Sonstiges (2)
- Forschungsdatensatz (1)
Schlagworte
- Traceability (35)
- Metrology (32)
- IDMS (19)
- Absolute isotope ratio (18)
- Isotope ratio (17)
- Uncertainty (17)
- CCQM (11)
- Measurement uncertainty (11)
- ICP-MS (10)
- Reference material (10)
- TIMS (10)
- Delta value (9)
- ICPMS (8)
- Isotope reference materials (8)
- Mass spectrometry (8)
- Copper (7)
- Reference materials (7)
- Cement (6)
- Comparability (6)
- Isotope fractionation (6)
- Isotope reference material (6)
- Metrology in chemistry (6)
- Atomic weight (5)
- Certification (5)
- Conventional isotope ratio (5)
- Delta reference materials (5)
- Herkunft (5)
- Isotope amount ratio (5)
- Isotope dilution (5)
- Magnesium (5)
- Purity (5)
- Sulfur (5)
- Triple isotope fractionation (5)
- Boron isotopes (4)
- Cadmium (4)
- Delta scale (4)
- Human serum (4)
- Interlaboratory comparison (4)
- Isotope (4)
- Isotope delta value (4)
- Isotope dilution mass spectrometry (4)
- Isotope ratios (4)
- Lead (4)
- MC-ICP-MS (4)
- Molar mass (4)
- Provenance (4)
- Purity assessment (4)
- SI traceability (4)
- Stable isotopes (4)
- Zinc (4)
- Archaeometry (3)
- Boron isotope variations (3)
- Delta values (3)
- Delta-scale (3)
- Iron (3)
- Isotopes (3)
- Lead isotopes (3)
- Palladium (3)
- Platinum (3)
- Synthetic isotope mixtures (3)
- Automotive exhaust emissions (2)
- Biodiesel (2)
- Biodiesel fuel (2)
- Bor (2)
- Boron (2)
- Boron isotope fractionation (2)
- CMC (2)
- CRM (2)
- Calibration (2)
- Circular economy (2)
- Geochemistry (2)
- Geological material (2)
- IRM (2)
- Isotope Dilution (2)
- Isotope delta (2)
- Isotopenverhältnisse (2)
- Lithium (2)
- Magnesium isotope ratios (2)
- Metrology in Chemistry (2)
- Milk (2)
- Provenance studies (2)
- SI (2)
- SI-traceability (2)
- Silicon (2)
- Soil (2)
- Sr isotopes (2)
- Surface analysis (2)
- TCE (2)
- Tetramethylammonium hydroxide (2)
- Transferrin (2)
- Uncertainty budget (2)
- boron (2)
- metrology (2)
- traceability (2)
- 87Sr/86Sr (1)
- AAS (1)
- Absolute Isotopenverhältnisse (1)
- Absolute isotope abundance (1)
- Algorithms (1)
- Alzheimer disease (1)
- Alzheimer’s disease (1)
- Amyloid-beta (1)
- Analyte-matrix separation (1)
- Analytical Chemistry (1)
- Analytical uncertainty (1)
- Antikensammlung Berlin (1)
- App (1)
- Archaeology (1)
- Archäometrie (1)
- Areal density (1)
- Argon (1)
- Ash content (1)
- Atomic Absorption Spectrometry (1)
- Atomic absorption spectrometry (1)
- Atomic weights (1)
- Authenticity (1)
- Automotive pollution (1)
- Avogadro constant (1)
- Bell (1)
- Bell pepper (1)
- Bioapatite (1)
- Biogenic carbonates (1)
- Biological boron recycling (1)
- Blank characterization (1)
- Blei (1)
- Blei-Isotopie (1)
- Bodenanalyse (1)
- Boron isotope (1)
- Boron isotopes in food (1)
- Boron isotopic composition (1)
- Boron monohydride (1)
- Boron transport (1)
- Brain (1)
- Branching ratio (1)
- Brassica napus (1)
- CCQM-P107 (1)
- CE/MC-ICP-MS (1)
- Calcification (1)
- Calcium (1)
- Catalytic converters (1)
- Cationic exchange (1)
- Cattle (1)
- Cconventional method (1)
- Cd mass fraction (1)
- Central Taurus (1)
- Cheese (1)
- Chenopodium album (1)
- Chromium (1)
- Ciaaw.org (1)
- Classical oven-drying (1)
- Classical primary measurement method (CPM) (1)
- Commercial moisture analyzer (1)
- Comparison (1)
- Conventional isotope ratios (1)
- Conventional method (1)
- Counting detector (1)
- Cross sections (1)
- Cu-64 (1)
- Curse tablets (1)
- Dairy cows (1)
- Data processing (1)
- Dead time (1)
- Degree of equivalence (1)
- Delta isotope standard (1)
- Delta notation (1)
- Delta-RM (1)
- Dementia (1)
- Detector deadtime (1)
- Determination of metrology of new cadmium atomic weight (1)
- Development (1)
- Diagenesis (1)
- Direct metal assay (1)
- Dissolution (1)
- Double IDMS (1)
- Double isotope dilution (1)
- Dual mode detector (1)
- EPMA (1)
- ERM (1)
- EURAMET (1)
- Elemental composition (1)
- Elemental fingerprints (1)
- Elemental mass spectrometry (1)
- Elementanalyse (1)
- Emissionen (1)
- Enriched isotope (1)
- Environmental pollution monitoring (1)
- Erythrocytes (1)
- Faecal monitoring (1)
- Feed (1)
- Feeding regime (1)
- Finow Canal (1)
- Fluchtafel (1)
- Food (1)
- Fossil fuel (1)
- Fuel (1)
- Fundamental science (1)
- GDMS (1)
- Graphite furnace (1)
- Gravimtric isotope mixtures (1)
- Greek curse tablets (1)
- Green Deal (1)
- Gypsum (1)
- HR-CS-MAS (1)
- Hafnium (1)
- Heavy metals (1)
- High purity metals (1)
- High-fired gypsum mortar (1)
- High-purity elements (1)
- High-resolution continuum source absorption spectrometry (1)
- High-resolution continuum source graphite furnace atomic absorption spectrometry (1)
- Hydrothermal fluid (1)
- Hyphenated (1)
- ICP-OES (1)
- ICP-TOFMS (1)
- ICP-ToF-MS (1)
- ID-ICP-MS (1)
- ID-MS (1)
- ILC (1)
- IMEP-9 (1)
- IUPAC Inorganic chemistry division (1)
- Iinductively coupled plasma mass spectrometry (1)
- Impurities (1)
- Impurity assessment (1)
- Impurity assessment approach (1)
- In-house calibration solution (1)
- Inductively coupled plasma (ICP) mass spectrometry (1)
- Inorganic chemical analysis (1)
- Inorganic impurities (1)
- Instrumental isotope fractionation (1)
- Interferences (1)
- Intra-plant isotope variability (1)
- Iridium (1)
- Iron isotope fractionation (1)
- Isobaric interferences (1)
- Isotope abundance (1)
- Isotope amount ratios (1)
- Isotope mixture (1)
- Isotope mixtures (1)
- Isotope purification (1)
- Isotope ratio mass spectrometry (1)
- Isotopenverhältnisse Strontium und Blei (1)
- Isotopenzusammensetzung (1)
- Isotopic Reference Material (1)
- Isotopic abundance variations (1)
- Isotopic analysis (1)
- Isotopic composition (1)
- Isotopic fractionation (1)
- Kalke (1)
- Karl Fischer titration (1)
- Kernkraftwerk (1)
- Kernkraftwerke (1)
- Kilogram (1)
- Königswasserextraktion (1)
- LA-(MC-)ICP-MS (1)
- LA-ICP-MS (1)
- LSVEC (1)
- Lagerstätten (1)
- Laser ablation (1)
- Lead isotope composition (1)
- Lead isotope ratios (1)
- Lead isotope variations (1)
- Lead isotopic composition (1)
- Legacy pollution (1)
- Low sulfur (1)
- MC-TIMS (1)
- MDG (1)
- MW-AES (1)
- Machine learning (1)
- Magnesium absorption (1)
- Magnesium stable isotopes (1)
- Mangesium (1)
- Mass discrimination (1)
- Mass fractionation (1)
- Massenspektrometrie (1)
- Matrix samples (1)
- Matrix separation (1)
- Measurement space (1)
- Measuremment uncertainty (1)
- Memory effect (1)
- Mercury (1)
- Mercury speciation (1)
- Metal assay approach (1)
- Metal sublimation (1)
- Methylmercury (1)
- Micro-sublimation (1)
- Microbially induced corrosion (1)
- Mittelalterliche Pilgerzeichen (1)
- Moisture (1)
- Mole (1)
- Molecular absorption (1)
- Multi-collector ICP-MS (1)
- Multi-collector inductively coupled plasma-mass spectrometry (ICP-MS) (1)
- Multi-element screening (1)
- Multicollector inductively coupled plasma mass spectrometry (1)
- NTD (1)
- Nanoparticles (1)
- Neutron activation (1)
- Neutron transmutation doping (1)
- Nickel (1)
- Nitrogen microwave inductively coupled atmospheric pressure mass spectrometry (1)
- Noise (1)
- Non-metal analysis (1)
- Open vessel digestion (1)
- Optimization (1)
- Ore provenance (1)
- PERM (1)
- PGE (1)
- PTI-MS (1)
- Pb isotope ratio thermal ionization mass spectrometry (1)
- Pb isotopes (1)
- Pepper (1)
- Petrol (1)
- Plant metabolism (1)
- Plant tissue (1)
- Plants (1)
- Platinum group elements (PGE) (1)
- Polarised light microscopy (1)
- Polyethylene (1)
- Polypropylene (1)
- Pore fluids (1)
- Portland cement (1)
- Portland clinker (1)
- Priam's treasure (1)
- Primary Isotopic Reference Material (1)
- Primary calibration solution (1)
- Primary difference measurement method (PDM) (1)
- Primary method of measurement (1)
- Primary transfer standards (PTSs) (1)
- Primäres Isotopenreferenzmaterial (1)
- Provenancing (1)
- Purity analysis (1)
- Purity determination (1)
- Quality system (1)
- Quantitative protein analysis (1)
- Radiogenic isotopes (1)
- Raman microspectroscopy (1)
- Raman spectroscopy (1)
- Re-evaluation (1)
- Reference data (1)
- Reference measurement (1)
- Reference measurement procedures (1)
- Reference measurements (1)
- Reference procedure (1)
- Review (1)
- Revision of the SI (1)
- River water (1)
- SF-ICP-MS (1)
- Sample-sample bracketing (1)
- Scale anchor (1)
- Scale conversion (1)
- Schwermetallbestimmung (1)
- Selenium (1)
- Serum (1)
- Silver artefacts (1)
- Single IDMS (1)
- Single Particle (1)
- Soil available boron (1)
- Spike (1)
- Sr and Nd isotope analysis (1)
- Sr isotope analysis (1)
- Stable isotope (1)
- Standard addition (1)
- Standard atomic weight (1)
- Statistical analysis (1)
- Strontium isotope (1)
- Strontium isotope ratio (1)
- Sulfur in oil (1)
- Sulphur (1)
- Sulphur isotope (1)
- Synthetic mixtures (1)
- TIMs (1)
- Tau (1)
- Technology-critical elements (1)
- Terminology (1)
- Thermal ionization mass spectrometry (1)
- Thermionenmassenspektrometrie (1)
- Thermogravimetry (1)
- Total element content (1)
- Total element determination (1)
- Toxic elements (1)
- Transient signal (1)
- Triple IDMS (1)
- Trojan silver artefacts (1)
- Trophic level (1)
- Unsicherheitsvergleiche (1)
- Uranium (1)
- Urinary monitoring (1)
- Urine (1)
- Validate method (1)
- Value assignment (1)
- WD-XRF (1)
- Water (1)
- Wet digestion (1)
- Wood chips (1)
- XRCD method (1)
- Ytterbium (1)
- absolute measurements (1)
- atomic weight (1)
- bell pepper (1)
- collision cell (1)
- delta value (1)
- enriched isotope (1)
- interferences (1)
- isotope fractionation (1)
- isotope ratio (1)
- isotope reference material (1)
- key comparison (1)
- lank characterization (1)
- magnesium (1)
- mass spectrometry (1)
- measurement uncertainty (1)
- metabolism (1)
- multi-collector (1)
- purity (1)
- reference material (1)
- silicon (1)
- species-specific isotope information (1)
- tandard addition (1)
- uncertainty budget (1)
- Ägyptisches Museum Berlin (1)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (89)
- 1.1 Anorganische Spurenanalytik (89)
- P Präsident (4)
- P.0 Präsident und andere (4)
- 1.3 Instrumentelle Analytik (3)
- 1.4 Prozessanalytik (3)
- 1.6 Anorganische Referenzmaterialien (3)
- S Qualitätsinfrastruktur (3)
- S.1 Qualität im Prüfwesen (3)
- 1.7 Organische Spuren- und Lebensmittelanalytik (2)
- 7 Bauwerkssicherheit (2)
- 7.4 Baustofftechnologie (2)
- 1.5 Proteinanalytik (1)
- 1.8 Umweltanalytik (1)
- 6 Materialchemie (1)
- 6.3 Strukturanalytik (1)
- 7.0 Abteilungsleitung und andere (1)
- PST Präsidiale Stabsstelle (1)
Eingeladener Vortrag
- nein (116)
Thermal ionisation, also known as surface ionisation, was one of the first ionisation techniques developed for mass spectrometry, having been invented as early as 1918. The ionization process, described by the empirically derived “fractionation laws”, is widely understood. Isotope ratio measurements can be achieved with high precision and accuracy. Due to this, thermal ionisation has paved the way for great scientific achievements including: the discovery of new isotopes, the determination of radioactive half-lives and atomic weights of the elements, the accurate determination of the age of the earth and investigations on human society in the past such as mobility and trade. TIMS is still regarded as ‘golden standard’ in isotope ratio measurements. Thus the method is a reference technique that remains at the forefront of isotopic analysis particularly in the fields of metrology. A concise overview is given here of the technical background of thermal ionisation as well as the numerous applications of this technique in earth sciences, industry, metrology, and nuclear forensics.
Pb isotope ratio analysis
(2023)
Sr isotope ratio analysis
(2023)
Detector deadtime
(2023)
Isotope Ratio Analysis
(2023)
Isotope reference materials are needed to calibrate and validate analytical procedures used for the determination of isotope amount ratios, procedurally defined isotope ratios or so-called δ values. In contrast to the huge analytical progress in isotope ratio analytics, the production of isotope reference materials has not kept pace with the increasing needs of isotope analysts. Three representative isotope systems are used to explain the technical and non-technical difficulties and drawbacks, on one hand, and to demonstrate what can be achieved at its best, on the other hand. A clear statement is given that new isotope reference materials are needed to obtain traceable and thus comparable data, which is essential for all kinds of isotope research. The range of available isotope reference materials and δ reference materials should be increased and matrix reference materials certified for isotope compositions or δ values, which do not exist yet, should be provided.
In the past, δ26/24Mg measurements were referenced to NIST SRM 980, the initial zero of the δ26/24Mg scale. With the development of MC-ICPMS, the detection of small but measurable isotopic differences in different chips of SRM 980 became apparent. To solve this problem a suite of magnesium isotope reference materials, ERM-AE143, -AE144 and -AE145, has been certified in a first study by applying an ab initio calibration for absolute Mg isotope ratios without any a priori assumptions, a procedure which fulfils all requirements of a primary method of measurement. We could achieve for the first time measurement uncertainties for isotope amount ratios close to the typical precision of magnesium delta values, δ26/24Mg, which are at the 0.1 ‰ level (2SD). In addition, it was demonstrated that commonly used fractionation laws are invalid for correcting Mg isotope ratios in multi-collector ICPMS as they result in a bias which is not covered by its associated uncertainty. Depending on their type, fractionation laws create a bias up to several per mil, with the exponential law showing the smallest bias between 0.1 ‰ to 0.7 ‰.
With these isotope reference materials, it is possible to establish SI-traceability for magnesium delta measurements. To realize this, we organized a second study within which five expert laboratories participated to cross-calibrate all available magnesium isotope standards, which are NIST SRM 980, IRMM-009, ERM-AE143, ERM-AE144, ERM-AE145 and the standards DSM3 and Cambridge-1. The mean δ26/24Mg values for the individual iRMs, calculated from the laboratory means show 2 SD reproducibilities varying between 0.025 and 0.093 ‰. Propagated measurement uncertainties suggest a standard uncertainty of about 0.1‰ for δ26/24Mg determinations (2SD). Thus, SI traceability for magnesium isotope amount ratios and delta values is demonstrated to be established.
HIIRM final report
(2002)
Accurate analytical results have become more and more an absolute essential tool for further progresses in technology and science. Precision however, often used in this context as a quality criterion for analytical methods, is not a replacement for accuracy in any way. Therefore, analytical procedures are necessary, which will generate reliable and accurate results and can be used for evaluation of other analytical procedures and certification of reference materials (RM). Especially the certification of reference materials for the amount content of trace elements requires highly accurate results with a small combined uncertainty. The best example for an analytical procedure having this capability is undoubtedly Isotope Dilution Mass Spectrometry, for inorganic as well as for organic applications. Applied on Thermal Ionization Mass Spectrometry (TIMS) isotope dilution provides results of highest quality and proven high accuracy especially in the field of RM certifications for more than 30 years.
The major drawback of this approach often is the necessity for a complex chemical separation step. A major advantage of Inductively Coupled Plasma Mass Spectrometry (ICP-MS) is the potential to cope with a simplified or an on-line-carried-out sample preparation. A key requirement of isotope dilution analysis however is the accurate and precise determination of isotope ratios, because of its limiting factor for the accuracy and the total uncertainty of the result. Very precise isotope ratios can be determined in combination with a detection system that is capable of simultaneous detection of different isotopes, a so-called multi-collector system.
The objective of the presented project is to evaluate the advantages of such a multi-collector ICP-MS for the application of IDMS in the field of trace elemental analysis in reference materials. The focus is on the development of simple and fast procedures for isotope ratio measurements in general and IDMS analysis in particular. Furthermore, it is an objective to develop and evaluate on-line spiking procedures.
One of the first conclusions, which had a severe impact on the HIIRM project, arose during the early days of the project. Currently most certification experiments are accomplished by certification campaign based on a variety of participants’ results. The sample preparation, sending, analyzing and data evaluation however require lot of resources and the process may take a long time. An alternative way is given by using fewer participants with methods of higher metrological quality. For elemental amount contents such a method undoubtedly is isotope dilution analysis and multi-collector ICP-MS offers the necessary precision and matrix robustness and ruggedness as said above. Therefore, a multiple collector ICP-MS was manufactured as part of the project instead of the originally planned high-resolution instrument. Due to the novelty of the multicollector ICP-MS instrument, a lot of additional fundamental research became necessary. Especially interferences needed further attention. Fortunately, the IsoProbe is additionally equipped with a high-resolution option and with a brand new collison cell. The high-resolution option however can only be used to identify interferences but cannot be used to quantify them. On the other hand, the use of the collision cell proved to be a vital tool to overcome interferences. This is especially true because high resolution would have reduced the available sensitivity by a factor of ~100. Applying the collision cell technology the high sensitivity was maintained whilst most interferences were eliminated. However finding the right parameters of operation for the collision cell became a huge part of the method development process. A variety of gases like argon, helium, hydrogen, deuterium, nitrogen, krypton and xenon were tested for their suitability. Especially the tests accomplished for iron determinations revealed that carefully selected parameters have an incredible influence on the quality of the final results. Nonetheless collision cell technology will undoubtedly be widely used for newer ICP-MS instrumentation and contribute to eliminate wrong analytical values caused by interferences.
The enhanced sensitivity of the instrument revealed also problems not detectable by other means. The control of contaminations seems to be one of the major analytical challenges in the future. Sector field based ICP-MS will give the user an opportunity to trace sources of contamination back to their origin and eliminate them. Even lower limits of detection will be the result as well as an enhanced reliability for analysts dealing with higher amount contents. The analyst will also benefit in controlling blank levels when the method of isotopically spiked procedure blanks is used as demonstrated in this project.
Another main part of the project was the validation of the developed procedures. The first validation step was successfully accomplished by applying these procedures on the standard solutions provided by NRG. The main part of this validation however consisted of the evaluation of the fundamental parameters of the isotope dilution process and related measurements. This approach turned out to be superior compaired to the first step as a highly reliable uncertainty calculation can be easily performed. The best reputation and acceptance of the methods can however only be accomplished by participating in certification campaigns or in interlaboratory comparisons on highest metrological level. The results of the participations in general were brilliant. Not only the results but also the obtained realistic uncertainties were of superior quality. Direct comparisons at BAM with the results obtained by a multicollector TIMS applying the same calculation schemes showed the benefits of using multicollector ICP-MS. The main benefits of ICP-MS were identified, of which the first one is the enhanced precision of the isotope ratio measurement. For a variety of elements the values obtained by multicollector ICP-MS are even more precise than the ones obtainable by multicollector TIMS. The second important advantage identified was the simplified sample preparation. The laborious and time consuming analyte-matrix-separation step as necessary for TIMS measurements can either be omitted or at least be drastically reduced. Therefore, the advantages regarding time and enhanced sample throughput will result in further spread of ICP-MS in general and multicollector ICP-MS in particular.
The third major part in terms of the method development process was mainly focused on developing an online isotope dilution system. The volumetric instead of the gravimetric IDMS approach proved difficult, if the high demands necessary for RM definition measurements are to be fulfilled. The major obstacle in this case is the missing stability and precision in terms of mass flow. Consequently, the initial development failed as the system made up of two piezoelectric droplet injectors was unable to reach the required stability as well as precision. The thereupon-created system consisting of two HPLC pumps proved to be far more valuable regarding automation and particularly the quantification of transient signals. Nevertheless, such a system will probably be rarely used in certification campaigns, as the gain of time is too small compared to the loss of reliability. However, this system proved most valuable in terms of species-specific elemental analysis as preliminary investigations showed. In this context this system will be suitable for certification measurements, as the major uncertainty contributions derive from sampling, sample treatment and species distribution and as moreover all availabel methods demonstrate far beyond.
During the whole project, one of the main concerns regarding the multicollector ICP-MS instrument were software issues caused by the early development state of the original control programs. A lot of effort was necessary to accomplish the necessary data manipulations externally. The development of a new software suite by Micromass for the HIIRM project has solved this issue almost completely. With the new software suite and the validated parameters of measurement a step forward for institutes dealing with reference material certifications was achieved.
Future certifications campaigns for minor elemental contents in different matrices should be performed by a small number of participants from highly qualified institutes. These institutes should apply very reliable methods of measurement like the ones developed in the HIIRM project. Many resources may be saved that way while the outcome of the certifications may easily be improved. ICP-MC-MS has the potential to be an important method in this context. Stable isotope dilution analysis in combination with a multi-detector ICP-MS, equipped with a hexapole collision cell for the suppression of important spectral interferences and for enhanced sensitivity, proved to be an advanced method of elemental analysis with a high potential for matrix independent measurements. Since ICP mass spectrometers of this type have only recently been introduced, no systematic evaluation of the capabilities of this specific application of the ICP-IDMS method has yet been made.
Roadmap for the purity determination of pure metallic elements – Basic rinciples and helpful advice
(2018)
High purity materials can serve as a realisation of the Système International d’Unitès (SI) unit amount of substance for the specific element. Solutions prepared from such high purity materials using gravimetric preparation and the concept of molar mass are used as calibration solutions in many fields of analytical chemistry. Calibration solutions prepared this way provide the traceability to the SI and are the metrological basis in elemental analysis.
The preparation and characterization of such primary pure substances, representing the realisation of the SI unit amount of substance, is undertaken only by a small number of National Metrology Institutes (NMI) and Designated Institutes (DI).
Many other NMIs and DIs, however, prepare elemental calibration solutions as calibrants for their measurement services, such as the certification of matrix Reference Materials or the provision of reference values for Proficiency Testing schemes. The elemental calibration solutions used for this purpose are not a direct service to customers, such as preparing secondary calibration solutions, but provide the source of traceability for the other services. Hence, it is necessary for the NMI or DI to obtain data on the purity of the pure metals or other materials used to prepare the solutions with measurement uncertainties meeting the needs of the above described services. This is commonly undertaken as a “fit for purpose” assessment, appropriate for the uncertainty requirement of the service provided to customers.
As a consequence, total purity measurements are a long-term strategy of CCQM-IAWG. Several studies were conducted (CCQM-P107, CCQM-K72 and CCQM-P149) on the measurement of the purity of zinc. From these studies, several conclusions can be drawn for the purity assessment of a pure (metallic) element. These conclusions will be put together in this document in order to assist all NMIs/DIs in performing a purity assessment, whenever needed.
Determination of absolute (SI‐traceable) isotope ratios: The use of Gravimetric Isotope Mixtures
(2023)
The presentation is brief overview on how to use gravimetric isotope mixtures to determine SI traceable isotope ratios. There is no mass spectrometer on earth that directly measures isotope ratios. Mass spectrometers will always measure signal intensity ratios instead. The actual problem is that the measured intensity ratios differ more or less from the isotope ratios. The difference can be up to more than 10 % in case of lithium while it‘s below 1 % in case of the heavier elements like lead or uranium. Consequently, the signal intensity ratios are expressed for example in V/V depending on the type of mass spectrometer you are using, while the isotope ratios are expressed in mol/mol. This phenomenon is called Instrumental Isotopic Fractionation (or short IIF) but the more common name is still mass bias (even though this name is not entirely correct). To convert the measured into the isotope ratio usually a simple multiplication with a so-called correction (or short K) factor is done. Therefore, the problem is to determine the K factor. In absence of isotope reference materials the golden route is via gravimetric isotope mixtures, which will be explained within the presentation.
The calibration of isotope ratio measurements is an ongoing challenge since instrumental isotope fractionation (IIF) has been detected in mass spectrometry (MS). There is a variety of approaches which either bypass IIF such as delta measurements or refer to reference materials (RMs) and thus shifting the problem of calibration to somebody else: the RM producer. For certifying isotope RMs with absolute isotope ratios only a few approaches are available, namely the isotope mixture approach, the double spike approach, the mass bias regression model and total evaporation in TIMS. All of them require either enriched isotopes, isotope RMs of another element or an RM for correcting residual error. As the enriched isotopes required for the isotope mixture and the double spike approach need to be fully characterized beforehand, all mentioned calibration approaches require a standard.
Here, a new and standard-free calibration approach for obtaining absolute isotope ratios of multi-isotopic elements has been developed. The underlying principle is that each MS suffers from IIF and thus yields a specific isotope fractionation line in a three-isotope diagram. When applying a second MS featuring a different ionization mechanism, we obtain a second isotope fractionation line with a different slope in the same three-isotope diagram. In both cases the absolute isotope ratios range somewhere on the isotope fractionation line. Consequentially, the intersect of both lines yield the absolute isotope ratios of the measured sample. This theory has been tested by measuring Cd and Pb isotope ratios of suitable isotope RMs with a TIMS and an ICP-MS, both equipped with multi-collector array. During the measurements the ionization conditions were changed such that different extent of the isotope fractionation has been achieved. With the resulting data set the theory described above could be verified. The obtained absolute isotope ratios were metrologically compatible with the certified isotope ratios. The remaining average bias of -5 ‰ can be reduced with further improvements. The calibration approach is universal and can be applied to any multi-isotopic element and it is not limited by the type of the mass spectrometer.
Production of three certified reference materials for the sulfur content in gasoline (petrol)
(2007)
Directive 2003/17/EC of the European Parliament and the European Council stipulates that petrol (gasoline) with a total sulfur content below 10 mg kg-1 must be available in all European Union member states by 2009. Three certified reference materials were produced in support of this directive in a joint effort of the members of the European Reference Materials Initiative (ERM). Two of the materials were made from commercial petrol, while the third one was prepared from a blend of commercial petrols. Relative between-ampule heterogeneity of the materials was quantified and found to be below 2.5%. Potential degradation during storage and dispatch was quantified, and shelf lives based on these values were set. The three materials were characterized by three institutes using different variants of isotope-dilution mass spectrometry. The results from the three institutes were combined, and the final uncertainties of the respective sulfur mass fractions were estimated including contributions from heterogeneity, stability, and characterization. The following mass fractions were derived: ERM-EF211, 48.8 ± 1.7 mg kg-1; ERM-EF212, 20.2 ± 1.1 mg kg-1; and ERM-EF213, 9.1 ± 0.8 mg kg-1.
The determination of the mass fractions of bromide, sulfate, and lead as well as the isotopic composition of the lead (expressed as the molar mass and the amount fractions of all four stable lead isotopes) in an aqueous solution of sodium chloride with a mass fraction of 0.15 g/g was the subject of this comparison. Even though the mass fractions ranged from 3 μg/g (bromide) to 50 ng/g (lead), almost all results reported agreed with the according KCRVs.
IRWG strategy update
(2023)
Stable isotope ratios and trace element concentrations of fossil bones and teeth are important geochemical proxies for the reconstruction of diet and past environment in archaeology and palaeontology. However, since diagenesis can significantly alter primary diet-related isotope signatures and elemental compositions, it is important to understand and quantify alteration processes. Here, we present the results of in-vitro Alteration experiments of dental tissues from a modern African elephant molar reacted in aqueous solutions at 30 °C and 90 °C for 4 to 63 days. Dental cubes with ≈ 3 mm edge length, comprising both enamel and dentin, were placed into 2 mL of acidic aqueous solution enriched in different isotopes (25Mg, 44Ca, 67Zn, 86Sr, initial pH 1). Element and isotope distribution profiles across the reacted cubes were measured with LA-(MC-)ICP-MS and EMPA, while potential effects on the bioapatite crystal structure were characterised by Raman spectroscopy. In all experiments isotope ratios measured by LA-(MC-)ICP-MS revealed an alteration of the enamel in the outer ≈ 200–300 μm. In contrast, dentin was fully altered (≈ 1.4 mm) after one week at 90 °C while the alteration did not exceed a depth of 150–200 μm during the 30 °C experiments. Then, the tracer solution started also to penetrate through the enamel-dentin junction into the innermost enamel, however, leaving the central part of the enamel unaltered, even after three months. The Raman spectra suggest an initial demineralisation in the acidic environment while organic matter (i.e. collagen) is still preserved. In the 90 °C experiment, Raman spectra of the v1 PO4) band of the dentin shift over time towards synthetic hydroxylapatite patterns and the Ca (and Sr) concentrations in the respective solutions decrease. This indicates precipitation of newly formed apatite. Isotope and element concentration profiles across the dental tissues reveal different exchange mechanisms for different isotope systems. Magnesium is leached from enamel and dentin, while Zn is incorporated into the apatite crystal structure. However, the distribution of both elements is not affected in the innermost enamel where their concentrations do not change over the whole duration of the experiments. We found no correlation of reaction depth in the cubes and experimental duration, which might be caused by natural variability of the dental material already at the beginning of the experiment. Our alteration experiments in a closed system at high temperatures ≤90 °C and low initial pH demonstrate that at least the central part of mm-thick mammalian enamel apatite seems to be resistant against alteration preserving its pristine bioapatite mineral structure as well as its in-vivo elemental and isotopic composition. The experiments assess diagenetic alteration in a novel multi-proxy approach using in-situ analyses in high spatial resolution. It is demonstrated that the isotopes of Ca, Sr, Zn and
Mg in the dentin are prone for diagenetic alteration, while enamel is more resistant against alteration and could be used for dietary and physiological reconstructions in fossil teeth.
KEY COMPARISON
High purity elements can serve as a realization of the SI unit amount of substance for the specific element. Solutions prepared from high purity metals by applying gravimetric preparation and the concept of molar mass are used as 'calibration' solutions in many fields of analytical chemistry and provide the metrological basis in elemental analysis. Since ideal purity does not exist for real materials, the actual purity of the high purity material must be known with a specified uncertainty. As required uncertainties around 10-4 relative on the purity statement are not accessible in almost all cases by a direct measurement of the element in itself, the indirect approach is followed, where all elements excepting the matrix element itself are measured and their sum is subtracted from the value for ideal purity, which is 1 kg/kg.
It was the aim of this comparison to demonstrate the capability of national metrology institutes and designated institutes to determine the purity of pure elements. In order to limit the effort within this comparison, only six metallic impurities (Ag, Al, Cd, Cr, Ni, Tl) in the low mg/kg range are considered in a zinc matrix. It has to be underlined here that the task was to measure the purity of zinc based on the determination of six analytes. The task is not trace analysis of specific analytes in zinc. This subtle distinction defines different measurands.
The sample, pure Zn, was cut in pieces of cubic geometry for wet chemical analysis or of pin geometry for GDMS analysis and was sent to the participants. The comparison was run under the auspices of the Inorganic analysis Working Group (IAWG) of the CCQM and was piloted by the BAM Federal Institute for Materials Research and Testing, Berlin, Germany. The majority of the participants applied ICP-MS techniques and only two participants used additionally atomic absorption spectrometry. GDMS was used only by one participant.
The observed spreads for the measurement results reported by the participants were significantly lower than those of the preceding study CCQM-P107 and were well below the target uncertainty of 30% relative. As a consequence, comparability within the participating laboratories is demonstrated to be established. The individual measurement results, mean values and medians derived were in all cases very consistent with the reference values obtained by IDMS and so the accuracy of the measurement results for the participating laboratories is as well demonstrated to be established. Especially with the results of CCQM-P62 and CCQM-P107 in mind, the outcome of CCQM-K72 can be considered as a big step forward in the community.
CCQM is aware of the difference between a characterization based on only six analytes and a complete characterization. Therefore, the pilot study CCQM-P149 has been initiated and already started, which focuses on the fit-for-purpose approaches for the purity determination of metals (here: zinc) to be used as primary standards in elemental analysis. Another follow-up in the form of a pilot study on non-metal impurities is mandatory, because non-metal impurities such as oxygen, nitrogen and sulfur often make up the largest contributions.
Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.
The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Three new offset Delta11B isotope reference materials for environmental boron isotope studies
(2011)
The isotopic composition of boron is a well established tool in various areas of Science and industry. Boron isotope compositions are typically reported as 5nB values which indicate the isotopic difference of a sample relative to the isotope reference material NIST SRM 951.
A significant drawback of all of the available boron isotope reference materials is that none of them covers a natural boron isotope composition apart from NIST SRM 951. To fill this gap of required 5UB reference materials three new solution boric acid reference materials were produced, which cover 6096o of the natural boron isotope Variation (-20 to 40%oo B) of about 100%o. The new reference materials are certified for their B values and are commercially available through European Reference Materials® (http://wwrv.enn-cmi.org). The newly produced and certified boron isotope reference materials will allow straightforward method Validation and quality control of boron isotope data.
The variation of isotope abundance ratios is increasingly used to unravell natural and technical questions. In the past the investigation and interpretation of such variations was the field of a limited number of experts. With new upcoming techniques and research topics in the last decades, such as provenance and authenticity of food, the number of published isotope data strongly increased. The development of inductively coupled plasma mass spectrometers (ICPMS) from an instrument for simple quantitative analysis to highly sophisticated isotope abundance ratio machines influenced this process significantly. While in former times only experts in mass spectrometry were able to produce reproducible isotope data, nowadays many laboratories, never been in touch with mass spectrometry before, produce isotope data with an ICPMS. Especially for such user isotope reference materials (IRM) are indispensible to enable a reliable method validation. The fast development and the broad availability of ICPMS also lead to an expansion of the classical research areas and new elements are under investigation. Here all users require IRM to correct for mass fractionation or mass discrimination or at least to enable isotope data related to a common accepted basis. Despite this growing interest suitable IRM are still lacking for a number of isotope systems such as magnesium.
Assessment of international reference materials for isotope-ratio analysis (IUPAC Technical report)
(2014)
Determination of the Pb isotopic composition in medieval pilgrim badges - Micro samples of approximately 1 mg or less were obtained from the backside of 12medieval pilgrim badges. After cleaning with water in an ultrasonic bath the samples were dissolved and the Pb was separated by chromtographic means. In the isolated Pb fractions the Pb isotope ratios were determined by thermal ionization mass spectrometry with expanded measurement uncertainties of less than 0.1 %. The determined Pb isotopic composition of the pilgrim badges spread over the whole range of the European and Mediterranean ore deposits. Nine of twelve pilgrim badges agree with Central European deposits, while three pilgrim badges show a different Pb isotopic composition covering either Mediterranean, or Aegean or Mid to Eastern European sources. Interestingly most of the ore deposits allocated by the Pb isotopic composition of the pilgrim badges do not agree with the known place of manufacture.
CCQM-P149 is an attempt to obtain a snapshot on actual procedures the NMIs and DIs within CCQM-IAWG applied to the purity characterization of their “fit for purpose” elemental Standards. This presentation describes how the results of CCQM-P149 may be used to underpin calibration and measurement capabilities being claimed in the BIPM database.
A set of 59 ancient magical artefacts, mainly made of lead, was selected from the collections of the Staatliche Museen zu Berlin in order to unravel their origins. All the selected artefacts have been studied for their Pb isotope compositions, which covered the whole range of the Mediterranean ore deposits. However, the majority (≈86%) were made of lead matching the small compositional range of the Laurion ore deposits. Only eight out of the 59 artefacts were made of recycled lead or lead from other ore deposits.
Additionally, all but two were approximately dated based on their inscriptions. The lead isotopic composition together with information obtained from the inscriptions, the resulting dating, the context of the find and the known history of each item allowed us to gain more detailed information about the origins of these magical artefacts. The Attic provenance of 36 curse tablets was confirmed, whereas for 11 curse tablets previously classified as non-Attic, the provenance was either confirmed and specified (six artefacts) or changed to Attic (five artefacts). Surprisingly, the majority (six out of eight) of the analysed curse tablets from the Egyptian collection showed a lead isotopic composition closely matching that of Laurion.
A Laurion-like lead isotopic composition was also observed for three of the four analysed oracular tablets from Dodona. Together with the dating information, this points to Laurion as the major and dominant lead source in the Aegean, at least during the fourth–third century B.C. The few curse tablets from earlier than the fourth–third century B.C. point to the use of multiple and thus isotopically more variable lead sources compared with the Roman times.
Knowledge about feeding behavior is essential to determine trophic interactions and reconstruct predator-prey relationships in modern and past foodwebs. Traditionally, nitrogen isotopes (δ15N) of collagen are used to quantify the ingestion of animal protein, however collagen usually does not preserve over geological time scales. To infer the diet of extinct vertebrates from fossil material more resistant dietary proxies such as Ca and Mg isotopes are needed, which are major elements in the bioapatite of bones and teeth. Magnesium is a bio-essential element that replaces calcium in the bioapatite lattice and bone and enamel δ26Mg values of extant mammals increase systematically along the foodchain [1, 2].
The existing δ26Mg data, however, is scarce, in particular with respect to carnivores, thus still limiting the capability of this dietary proxy to reliably determine trophic differences between plant- and animal-feeders. To better constrain trophic-level effects recorded in Mg isotopes, we analyzed δ26Mg of bioapatite from modern mammals with a focus on faunivores, both carnivores and as yet unexplored insectivores.
The trophic level effect of δ26Mg is influenced by the geological substrate which causes isotope variability in δ26Mg of faunal remains between different ecosystems [1, 2]. Therefore, as first-order proxy for sample provenance and to assess potential influences of the bedrock substrate of the animals´ habitats on δ26Mg of bones and teeth, we measured the 87Sr/86Sr on the same specimens. This information will enable us to refine trophic level effects and determine whether δ26Mg can be used to distinguish different faunivores isotopically. This will be of paramount importance for dietary reconstructions of trophic niches in fossil foodwebs.
[1] Martin et al. (2014) Geochmica Cosmochimica Acta 130, 12-20. [2] Martin et al. (2015) Proceedings of the National Academy of Sciences 112, 430-435.
In isotope ratio applications metrological principles such as measurement uncertainty and SI traceability often are not considered or realized. This is also well-documented by the traceability exception related to delta scale isotope ratio measurements CCQM requested from the CIPM. Generally, delta scale isotope ratio measurements can be performed on a precision level that is significantly lower than the uncertainty level of isotope amount ratio measurements. In the case of magnesium, we demonstrated for the first time that isotope amount ratios can be measured with uncertainties close to the typical precision of magnesium delta values, δ26/24Mg, which are at the 0.1 ‰ level.
In the past, δ26/24Mg measurements were referenced to NIST SRM 980, the initial zero of the δ26/24Mg scale. With the development of MC-ICPMS, the detection of small but measurable isotopic differences in different chips of NIST SRM 980 became apparent and NIST SRM 980 was replaced by an intermediate artefact, DSM3. To solve this problem a suite of magnesium isotope reference materials, ERM-AE143, -AE144, and -AE145, has been certified in a first study by applying an ab initio calibration for absolute Mg isotope ratios without any a priori assumptions, a procedure which fulfils all requirements of a primary method of measurement. Thus, these materials qualified to establish SI-traceability for magnesium delta measurements. In a second study five expert laboratories participated to cross-calibrate all available magnesium isotope standards, which are NIST SRM 980, IRMM-009, ERM-AE143, ERM-AE144, ERM-AE145 and the standards DSM3 and Cambridge-1. The mean δ26/24Mg values for the individual iRMs, calculated from the laboratory means show 2 SD reproducibilities varying between 0.025 and 0.093 ‰. Propagated measurement uncertainties suggest a standard uncertainty of about 0.1 ‰ for δ26/24Mg determinations. Thus, SI traceability for magnesium isotope amount ratios and delta values is demonstrated to be established.
Multi-collector inductively coupled plasma-mass spectrometry (MC-ICP-MS) has evolved significantly since its introduction in 1992. The second and third generation instruments now allow isotope ratio measurements at unprecedented precisions, 0.001 % or better. However, precision alone is not enough for producing accurate and reliable isotope ratio measurements. Metrological considerations such as the selection of suitable calibration strategies, proper assessment of instrumental biases, and the estimation of overall measurement uncertainty remain critical to the measurement process. Properly assessed, measurement uncertainty then provides the interval within which a result can be considered both accurate and precise.
All mass spectrometric measurements are affected by instrumental mass discrimination and produce isotope ratios that are biased relative to their “true” ratio. To produce accurate and traceable isotope ratio measurements, it is imperative that certified isotope reference materials (iCRMs) be used for calibration and validation purposes. iCRMs reporting absolute isotope ratios are an analyst’s first choice, particularly when its uncertainty is sufficient for the intended use. However, when smaller uncertainties are required to resolve subtle differences between samples, delta-scale measurements become important. Here, the difference between an isotope ratio measured in a sample and in an internationally accepted isotope reference material (iRM) is determined. This deviation can be positive or negative relative to the iRM, is called a delta value, and is often expressed in per mil units.
This presentation will highlight the potential for MC-ICP-MS to produce isotope ratio measurements with minimal uncertainties by examining three applications involving Mg isotopes: 1) the certification of a set of iCRMs for their absolute isotope ratio using a gravimetric isotope mixture approach; 2) the comparison of these iCRMs with currently accepted Mg delta-scale reference materials through intercalibration, and 3) the determination of isotope fractionation exponents for geochemical applications.
An introduction into absolute isotope ratios is given, with application fields ranging from fundamental science to geochronology and forensics. This is followed by a proposal for developing new calibration approaches for obtaining absolute isotope ratios at unrivaled uncertainty levels. This new developments will set the basis for improvements in all scientific fields.
Introduction: The influence of copper, iron and zinc concentrations on the formation of ß-amyloid plaques and neurofibrillary tangles in Alzheimer’s disease (AD) is widely discussed in the community. The results from human and animal studies so far are mixed with some studies showing a correlation and others not. From a number of studies, it is known that disease state and isotopic composition of essential elements can be coupled.
Aim: The aim of the study was to identify changes in element content and isotopic composition in two transgenic mouse models used in AD research compared to their genetic WT relatives and to establish whether element content and isotopic signature between different laboratories is comparable.
Methods: ß-amyloid (5xFAD) and tau overexpressing (L66) mice together with their matching wild-types were bred at dedicated facilities in accordance with the European Communities Council Directive (63/2010/EU). Serum and brain were sampled after sacrifice and the samples distributed among the participants of the study. The tissues were acid digested for total element determination and high-precision isotope ratio determination. Element content was determined by either sector-field or quadrupole-based inductively coupled plasma mass spectrometry (ICPMS). For the determination of isotope ratios multi-collector ICPMS was used.
Results: Total copper content was significantly higher for L66 and their matched WT compared to 5xFAD and WT. Brains of L66 mice contained more Fe in brain than their WT, Zn and Cu were not significantly different between L66 and WT. Whereas 5xFAD mice had a slightly lower Cu and slightly higher Zn concentration in brain compared to WT. The isotopic signature in brain of L66 mice for Fe was different from their controls, whereas Zn isotope ratios were influenced in 5xFAD mice compared to their WT . The Cu isotopic ratio did not seem to be influenced in either strain. In serum, the shifts were less pronounced.
Conclusion: Even though neither Tau-protein nor amyloid precursor protein are known to be metal-dependent / -containing proteins, the overexpression of both influences the Fe, Cu and Zn metabolism in brain and to some extent also in serum as can be seen not only using total element determination but probably more clearly studying the isotopic signature of Fe, Cu and Zn.
Development and validation of a method to determine the boron isotopic composition of crop plants
(2011)
We present a comprehensive chemical and mass spectrometric method to determine boron isotopic compositions of plant tissue. The method including dry ashing, a three-step ion chromatographic boron–matrix separation, and 11B/10B isotope ratio determinations using the Cs2BO2+ graphite technique has been validated using certified reference and quality control materials. The developed method is capable to determine δ11B values in plant tissue down to boron concentrations of 1 mg/kg with an expanded uncertainty of ≤1.7‰ (k = 2). The determined δ11B values reveal an enormous isotopic range of boron in plant tissues covering three-quarters of the natural terrestrial occurring variation in the boron isotopic composition. As the local environment and anthropogenic activity mainly control the boron intake of plants, the boron isotopic composition of plants can be used for food provenance studies.
The isotopic composition of boron is a well established tool in various areas of Science and industries. Boron isotope compositions are typically reported as 6"B values which indicate the isotopic difference of a sample relative to the internationally accepted isotope reference material NIST SRM 951. A significant drawback of all of the available boron isotope reference materials is that non covers a natural boron isotope composition apart from NIST SRM 951.
Comparative performance study of ICP mass spectrometers by means of U "isotopic measurements"
(2000)
The performance of four commercially available ICPMS instruments of three different types was compared by means of uranium "isotopic measurements". Examined were two quadrupole sector (different generation, different manufacturer), one single detector double focusing magnetic sector and one multiple collector double focusing magnetic sector instruments. The same samples of the IRMM-072 series were used under routine conditions to measure the 233U/235U and the 233U/238U ratios which, in these samples, vary over almost three orders of magnitude from ~ 1 to ~ 2 · 10-3. Within expanded (k = 2) uncertainties, good agreement was observed between the certified values and the data internally corrected for mass-discrimination effects. The magnitude of the evaluated uncertainties was different for each type of instrument. With the multiple collector instrument, expanded uncertainties varied from - 0.04% to- 0.24% for the 233U/235U ratio, and from - 0.08% to - 0.27% for the 233U/238U ratio. They were ~ 1 to 5 times larger with the single detector magnetic sector instrument, and ~ 10 to 25 times larger with both quadrupole sector instruments. With the multiple collector instrument, repeatability of the measurements seemed to be limited by the difficulty of correcting properly for instrumental background, whereas with the single detector magnetic sector instrument the counting statistics was the only limitation (on smallest ratios). Apparent mass-discrimination was clearly found to be larger but more reproducible (and hence easier to correct for) in the case of magnetic sector instruments than for both quadrupole sector instruments. If space charge effects were the main source of mass-discrimination for all instruments, these results are in contradiction with the hypothesis of the size of mass-discrimination decreasing with the acceleration voltage. With the single detector magnetic sector instrument in particular (when operated by changing the ion energy only), our results pointed at more than only one major source of mass-discrimination, with variable size depending on the ratios measured.
The present paper describes the certification of the amount content of Cd, Cr and Pb in two different polyethylene materials within the third phase of the Polyethylene Elemental Reference Material (PERM) project. The analytical procedure to establish the reference values for Cd, Cr and Pb amount contents in these materials is based on isotope dilution mass spectrometry used as a primary method of measurement. Cd and Pb were measured with inductively coupled plasma-mass spectrometry and Cr with positive thermal ionization-mass spectrometry. The decomposition of the polymer matrix was carried out using a high pressure asher. Reference values for amount content, traceable to the SI-system, have been obtained for these three elements in both of the polyethylene samples of PERM. For each of the certified amount content values an uncertainty budget was calculated using the method of propagation of uncertainties according to ISO and EURACHEM guidelines. The measurement procedures, as well as the uncertainty calculations, are described for all three elements. In order to keep the whole certification process as transparent as possible, the preparations of various reagents and materials as well as the sample treatment and blending are described in detail. The mass spectrometry measurements and the data treatment are also explained carefully. The various sources of uncertainty present in the procedure are displayed in the uncertainty budgets. The obtained combined uncertainties for the amount content values were less than 2% relative (k=1) for all investigated elements. The amount contents were in the ?mol/kg range, corresponding to mg/kg levels.
Gravimetric synthetic mixtures of seven enriched, purified cadmium isotope materials were used to determine the correction factors for mass fractionation (MC-TIMS) and mass discrimination (MC-ICP-MS). The isotope abundance ratios determined for various natural cadmium materials represents the isotope composition for natural cadmium materials. Correction of the isotope abundance ratios observed yielded isotope abundances of 106Cd 0.012450(8), 108Cd 0.008884(4), 110Cd 0.124846(16), 111Cd 0.127955(14), 112Cd 0.241110(38), 113Cd 0.122254(22), 114Cd 0.287439(60) and 116Cd 0.075183(32). The newly determined atomic weight of natural cadmium based on SI-traceable evaluation of the isotope abundance ratios is 112.41384(18). The cadmium material designated in the paper as Cd-2211 can be used as an isotope reference material with a δ(114Cd/110Cd)-value of 0. The results obtained show that the uncertainties for the isotope abundances and the atomic weight given as IUPAC values for cadmium are overestimated.
Isotopenanalytik an der BAM
(2007)