Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (117)
- Zeitschriftenartikel (109)
- Posterpräsentation (26)
- Forschungsbericht (11)
- Beitrag zu einem Sammelband (8)
- Beitrag zu einem Tagungsband (8)
- Buchkapitel (3)
- Sonstiges (2)
- Corrigendum (1)
- Forschungsdatensatz (1)
Schlagworte
- Traceability (36)
- Metrology (33)
- IDMS (19)
- Absolute isotope ratio (18)
- Uncertainty (18)
- Isotope ratio (17)
- CCQM (11)
- Measurement uncertainty (11)
- ICP-MS (10)
- Reference material (10)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (80)
- 1.1 Anorganische Spurenanalytik (80)
- 1.6 Anorganische Referenzmaterialien und Gasanalytik (5)
- P Präsident (5)
- P.0 Präsident und andere (5)
- S Qualitätsinfrastruktur (4)
- S.1 Qualität im Prüfwesen (4)
- 1.3 Instrumentelle Analytik (3)
- 1.4 Non-Target-Analytik (2)
- 1.7 Organische Spuren- und Lebensmittelanalytik (2)
An introduction into absolute isotope ratios is given, with application fields ranging from fundamental science to geochronology and forensics. This is followed by a proposal for developing new calibration approaches for obtaining absolute isotope ratios at unrivaled uncertainty levels. This new developments will set the basis for improvements in all scientific fields.
Isotope Ratio Measurements
(2015)
Three petrol reference materials were certified for their total sulfur content in support of Directive 2003/17/EC of the European Parliament and of the European Council, which stipulates that petrol with a maximum S content of 10 mg/kg must be available in all member states by 2009. Commercially available petrol was obtained and filled into borosilicate ampoules without further treatment. Homogeneity of the materials was tested and no heterogeneity was detected for two of the materials, whereas minor heterogeneity was observed for the third material. Stability of the materials was tested for 8-12 months at 60 °C and no degradation was observed. Characterisation was based on isotope-dilution mass spectrometry (IDMS) applied as primary method of measurement by three European metrology institutes and certified values were assigned using all results. The certified uncertainties include contributions of (potential) heterogeneity, potential degradation as well as characterisation. The final assigned values are:
ERM-EF211: 48.8 ± 1.7 mg/kg
ERM-EF212: 20.2 ± 1.1 mg/kg
ERM-EF213: 9.1 ± 0.8 mg/kg
The materials are available from IRMM (ERM-EF211), LGC (ERM-EF212) and BAM (ERMEF213)
Certification report for the reference materials ERM-AE102a, -AE104a, -AE120, -AE121 and -AE122
(2010)
Isotope reference materials are essential to enable reliable and comparable isotope data. Besides the correction of mass fractionation or mass discrimination isotope reference materials are indispensible for validation and quality control of analytical procedures. This article describes the production and certification of a set of five isotope reference materials ERM-AE102a, 104a, AE120, 121 and 122, for boron isotope analysis. The isotopic composition of all materials has been adjusted by mixing boron mother solutions enriched in 10B or 11B with a boron mother solution having natural-like isotopic composition under full gravimetric control. All mother solutions have been analysed for their boron mass fraction as well as their boron isotopic composition by TIMS using IDMS as calibration technique. For all five reference materials the isotopic composition obtained on the basis of the gravimetric data agrees very well with the isotopic composition obtained from different TIMS techniques. Performed stability and homogeneity studies show no significant influence on the isotopic composition as well as on the related uncertainties.
The certified isotope abundances for 10B are 0.29995 (27) for ERM-AE102a and 0.31488 (28) for ERM-AE104a. The certified δ11B values are -20.2 (6) ‰ for ERM-AE120, 19.9(6) ‰ for ERM-AE121 and 39.7 (6) ‰ for ERM-AE122.
Together with the formerly certified ERM-AE101 and -AE103 a unique set of seven certified reference materials (CRM) for boron isotope analysis is now available from BAM.
Isotope reference materials are essential to enable reliable and comparable isotope data. Besides the correction of mass fractionation or mass discrimination, isotope reference materials are indispensible for validation and quality control of analytical procedures. This report describes the production and certification of two isotope reference materials, ERM-AE123 and ERM-AE124, for boron isotope analysis. The isotopic composition of ERM-AE123 is the unaltered natural-like isotopic composition of the base material. The isotopic composition of ERM-AE124 has been adjusted by mixing two boron stock solutions enriched in 10B and 11B respectively under full gravimetric control. All stock solutions have been prepared fully under gravimetrical control. The corresponding boron isotopic composition has been analysed by TIMS. For both reference materials the isotopic composition obtained on the basis of the gravimetric data agrees very well with the isotopic composition obtained by TIMS. The certified isotope abundances for 10B are 0.19832 (21) for ERM-AE123 and 0.96006 (6) for ERM-AE124. Together with the formerly certified ERM-AE101, -AE102a, -AE103, -AE104a, -AE120, -AE121 and AE122, a unique set of nine certified reference materials (CRM) for boron isotope analysis is now available from BAM covering a range for the 10B isotope amount fraction from 0.2 to 0.96 and for the δ11B value from -20 ‰ to +40 ‰.
Isotope dilution mass spectrometry often is applied for the quantification of platinum group elements in environmental and geological samples. In most cases, however, certified spike solutions offering complete uncertainty statements and SI-traceability are missing. This report describes the production and certification of two isotope reference materials, ERM-AE140 and ERM-AE141, serving as calibrated spike solutions for IDMS based quantification of Pd and Pt, respectively. Both materials were produced by dissolving highly enriched isotopes 106Pd and 194Pt and determining the mass fraction of 106Pd and 194Pt in the final solution by reverse IDMS. Two independent back-spikes were produced for each material from high purity Pd and Pt. Characterization measurements were carried out by MC-ICPMS. For ERM-AE140 the certified mass fractions are w(106Pd) = 20.24(5) mg/kg and w(Pd) = 20.54(5) mg/kg. For ERM-AE141 the certified mass fractions are w(194Pt) = 18.18(11) mg/kg and w(Pt) = 19.90(12) mg/kg. These values are traceable to the International System of Units (SI) in the shortest possible way.
Dieser Bericht beschreibt die Herstellung und Zertifizierung einer Cadmiumlösung mit natürlicher Isotopenzusammensetzung. Für das Isotopen-Referenzmaterial sind sowohl die Isotopenverhältnisse als auch Isotopenhäufigkeiten und die molare Masse von Cadmium zertifiziert. Die Unsicherheiten sind erweiterte Messunsicherheiten U = k.uc mit k = 2. Der Cadmium-Massenanteil in der Lösung wird als indikativer Wert angegeben mit einer erweiterten Messunsicherheit U = k.uc mit k = 4,5.