In many laser based ionization techniques with a subsequent drift time separation, the laser pulse generating the ions is considered as the start time t0. Therefore, an accurate temporal definition of this event is crucial for the resolution of the experiments. In this contribution, the laser induced plume dynamics of liquids evaporating into atmospheric pressure are visualized for two distinctively different laser pulse widths, Δt = 6 nanoseconds and Δτ = 280 microseconds. For ns-pulses the expansion of the generated vapour against atmospheric pressure is found to lead to turbulences inside the gas phase. This results in spatial and temporal broadening of the nascent clouds. A more equilibrated expansion, without artificial smearing of the temporal resolution can, in contrast, be observed to follow μs-pulse excitation. This leads to the counterintuitive finding that longer laser pulses results in an increased temporal vapour formation definition. To examine if this fume expansion also eventually results in a better definition of ion formation, the nascent vapour plumes were expanded into a linear drift tube ion mobility spectrometer (IMS). This time resolved detection of ion formation corroborates the temporal broadening caused by collisional impeding of the supersonic expansion at atmospheric pressure and the overall better defined ion formation by evaporation with long laser pulses. A direct comparison of the observed results strongly suggests the coexistence of two individual ion formation mechanisms that can be specifically addressed by the use of appropriate laser sources.
An airborne laser plasma is suggested as an ambient ion source for mass spectrometry. Its fundamental physical properties, such as an excellent spatial and temporal definition, high electron and ion densities and a high effective cross section in maintaining the plasma, make it a promising candidate for future applications. For deeper insights into the plasma properties, the optical plasma emission is examined and compared to mass spectra. The results show a seemingly contradictory behavior, since the emitted light reports the plasma to almost entirely consist of hot elemental ions, while the corresponding mass spectra exhibit the formation of intact molecular species. Further experiments, including time- resolved shadowgraphy, spatially resolved mass spectrometry, as well as flow-dependent emission spectroscopy and mass spectrometry, suggest the analyte molecules to be formed in the cold plasma vicinity upon interaction with reactive species formed inside the hot plasma center. Spatial separation is maintained by concentrically expanding pressure waves, inducing a strong unidirectional diffusion. The accompanying rarefaction inside the plasma center can be compensated by a gas stream application. This replenishing results in a strong increase in emission brightness, in local reactive species concentration, and eventually in direct mass spectrometric sensitivity. To determine the analytical performance of the new technique, a comparison with an atmospheric pressure chemical ionization (APCI) source was conducted. Two kitchen herbs, namely, spearmint and basil, were analyzed without any sample pretreatment. The presented results demonstrate a considerably higher sensitivity of the presented laser-spark ionization technique.
A wide range of aspects concerning microscope slides, their preparation, long-time storage, curatorial measures in collections, deterioration, restoration, and study is summarized based on our own data and by analyzing more than 600 references from the 19th century until 2016, 15 patents, and about 100 Materials Safety Data Sheets. Information from systematic zoology, conservation sciences, chemistry, forensic sciences, pathology, paleopathology, applied sciences like food industry, and most recent advances in digital imaging are put together in order to obtain a better understanding of which and possibly why mounting media and coverslip seals deteriorate, how slides can be salvaged, which studies may be necessary to identify a range of ideal mounting media, and how microscope studies can benefit from improvements in developmental biology and related fields. We also elaborate on confusing usage of concepts like that of maceration and of clearing.
The chemical ingredients of a range of mounting media and coverslip seals are identified as much as possible from published data, but this information suffers in so far as the composition of a medium is often proprietary of the manufacturer and may vary over time. Advantages, disadvantages, and signs of deterioration are documented extensively for these media both from references and from our own observations. It turns out that many media degrade within a few years, or decades at the latest, except Canada balsam with a documented life-time of 150 years, Euparal with a documented life-time of 50 years, and glycerol-paraffin mounts sealed with Glyceel, which represents almost the only non-deteriorating and easily reversible mount. Deterioration reveals itself as a yellowing in natural resins and as cracking, crystallization, shrinkage on drying or possibly on loss of a plasticizer, detachment of the coverslip, segregation of the ingredients in synthetic polymers, as well as continued maceration of a specimen to a degree that the specimen virtually disappears. Confusingly, decay does not always appear equally within a collection of slides mounted at the same time in the same medium. The reasons for the deteriorative processes have been discussed but are controversial especially for gum-chloral media. Comparing data from conservation sciences, chemical handbooks, and documented ingredients, we discuss here how far chemical and physical deterioration probably are inherent to many media and are caused by the chemical and physical properties of their components and by chemicals dragged along from previous preparation steps like fixation, chemical maceration, and physical clearing. Some recipes even contain a macerating agent, which proceeds with its destructive work. We provide permeability data for oxygen and water vapor of several polymers contained in mounting media and coverslip seals. Calculation of the penetration rate of moisture in one example reveals that water molecules reach a specimen within a few days up to about a month; this lays to rest extensive discussions about the permanent protection of a mounted specimen by a mounting medium and a coverslip seal.
Based on the ever growing evidence of the unsuitable composition and application of many, and possibly almost all, mounting media, we strongly encourage changing the perspective on microscope slides from immediate usability and convenience of preparation towards durability and reversibility, concepts taken from conservation sciences. Such a change has already been suggested by Upton (1993) more than 20 years ago for gum-chloral media, but these media are still encouraged nowadays by scientists. Without a new perspective, taxonomic biology will certainly lose a large amount of its specimen basis for its research within the next few decades. Modern non-invasive techniques like Raman spectroscopy may help to identify mounting media and coverslip seals on a given slide as well as to understand ageing of the media. An outlook is given on potential future studies.
In order to improve the situation of existing collections of microscope slides, we transfer concepts as per the Smithsonian Collections Standards and Profiling System, developed for insect collections more than 25 years ago, to collections of slides. We describe historical and current properties and usage of glass slides, coverslips, labels, and adhesives under conservational aspects. In addition, we summarize and argue from published and our own experimental information about restorative procedures, including re-hydration of dried-up specimens previously mounted in a fluid medium. Alternatives to microscope slides are considered. We also extract practical suggestions from the literature concerning microscope equipment, cleaning of optical surfaces, health risks of immersion oil, and recent improvements of temporary observation media especially in connection with new developments in digital software.
A novel ionization scheme for ambient mass spectrometry is presented and discussed. Desorption and ionization are achieved by a quasi-continuous laser induced plasma (LIP) ignited in front of the atmospheric pressure interface of a time-of-flight mass spectrometer. This setup comprises the advantages of i) an ambient probe, ii) electro neutrality, iii) low power consumption, iv) a sufficient duty cycle, v) a ubiquitous plasma medium (air) and vi) high sensitivity caused by the high electron number densities.
The plasma properties and operating conditions are investigated to understand the processes that lead to the formation of molecular ions. Comprehensive studies include optical emission spectroscopy, shadowgraphic shockwave visualization and time-of-flight mass spectrometry investigations. The observed MS signal (including reagent-ion signal, as well as analyte spectra) closely resembles the ionization behavior of other electrically-driven plasma-based ionization sources, such as DBD, LTP or DART. Conversely that means that although LIPs are commonly known to have temperatures way above 10.000 K and thus efficiently atomize and ionize molecules, MS spectra were obtained that showed the formation of intact molecular ions.
For an insight into the LIP properties the optical emission of the LIP is examined and exhibits a pronounced degree of dissociation into atomic and ionic species, which reflects the higher temperature and electron density inside a LIP. Accordingly, rather elemental (ICP-type) than molecular spectra should be expected. However due to the absence of such ions, we conclude that the analyte does not enter the hot center of the plasma itself. Moreover, the initial, highly-excited plasma species react cascade-like to lower energetic species via reactive collision with the surrounding atmosphere, which can then subsequently ionize molecules of interest. The concept potentially involves charge transfer, proton transfer, electron impact and photoionization.
These assumptions are confirmed via the shadowgraphs of the expanding shockwave around the LIP. An effective spatial separation between the two regions is maintained by concentrically expanding pressure waves resulting in a strongly unidirectional diffusion. Additionally, the strictly outbound matter transport suggests a rarefaction inside the plasma region for each plasma event.
A novel ionization scheme for ambient mass spectrometry is presented and discussed. Desorption and ionization are achieved by a quasi-continuous laser induced plasma (LIP) ignited in front of the atmospheric pressure interface of a time-of-flight mass spectrometer. This setup comprises the advantages of i) an ambient probe, ii) electro neutrality, iii) low power consumption, iv) a sufficient duty cycle, v) a ubiquitous plasma medium (air) and vi) high sensitivity caused by the high electron number densities.
The plasma properties and operating conditions are investigated to understand the processes that lead to the formation of molecular ions. Comprehensive studies include optical emission spectroscopy, shadowgraphic shockwave visualization and time-of-flight mass spectrometry investigations. The observed MS signal (including reagent-ion signal, as well as analyte spectra) closely resembles the ionization behavior of other electrically-driven plasma-based ionization sources, such as DBD, LTP or DART. Conversely that means that although LIPs are commonly known to have temperatures way above 10.000 K and thus efficiently atomize and ionize molecules, MS spectra were obtained that showed the formation of intact molecular ions. For an insight into the LIP properties the optical emission of the LIP is examined and exhibits a pronounced degree of dissociation into atomic and ionic species, which reflects the higher temperature and electron density inside a LIP. Accordingly, rather elemental (ICP-type) than molecular spectra should be expected. However due to the absence of such ions, we conclude that the analyte does not enter the hot center of the plasma itself. Moreover, the initial, highlyexcited plasma species react cascade-like to lower energetic species via reactive collision with the surrounding atmosphere, which can then subsequently ionize molecules of interest. The concept potentially involves charge transfer, proton transfer, electron impact and photoionization.
These assumptions are confirmed via the shadowgraphs of the expanding shockwave around the LIP. An effective spatial separation between the two regions is maintained by concentrically expanding pressure waves resulting in a strongly unidirectional diffusion. Additionally, the strictly outbound matter transport suggests a rarefaction inside the plasma region for each plasma event.
Coulomb fission of charged droplets (The terms drop and droplet are often used synonymous. Throughout this manuscript, to avoid confusion, the terms drop and droplet will be used for liquid spheres with radii in the millimeter range and the micrometer range, respectively. In our experiments, the first correspond to the parent drop while the latter describes the ejected progeny droplets.) is a wellstudied natural phenomenon. Controlled droplet fission is already successfully employed in several technological applications. Still, since the occurring surface rupture relies on the exact understanding and description of the liquid gas boundary, some details are still under debate. Most empirical systematic studies observe falling micrometer droplets passing through the electric field inside a plate capacitor. This approach, although easily applicable and reliable, limits the experimental degrees of freedom regarding the observable time and the maximum size of the drops and can only be performed in consecutive individual observations of different subsequent drops. Here we present a novel setup to study the field induced breakup of acoustically levitated drops. The design does not bear any restrictions towards the temporal window of observation, and allows handling of drops of a tunable radius ranging from 10 µm to several millimeters and a real-time monitoring of one single drop. Our comprehensive study includes a time resolved visual inspection, laser shadowgraphy, laser induced fluorescence imaging, and ambient mass spectrometric interrogation of the nascent Taylor cone. The results shown for a millimeter sized drop, previously inaccessible for Coulomb fission experiments, are mostly comparable with previous results for smaller drops. The major difference is the time scale and the threshold potential of the drop rupture. Both values, however, resemble theoretically extrapolations to the larger radius. The technique allows for a systematic study of breakup behavior of drops of different charge, material, and size.
Driven mostly by the search for chemical syntheses under biocompatible conditions, so called "click" chemistry rapidly became a growing field of research. The resulting simple one-pot reactions are so far only scarcely accompanied by an adequate optimization via comparably straightforward and robust analysis techniques possessing short set-up times. Here, we report on a fast and reliable calibration-free online NMR monitoring approach for technical mixtures. It combines a versatile fluidic system, continuous-flow measurement of 1H spectra with a time interval of 20 s per spectrum, and a robust, fully automated algorithm to interpret the obtained data. As a proof-of-concept, the thiol-ene coupling between N-boc cysteine methyl ester and allyl alcohol was conducted in a variety of non-deuterated solvents while its time-resolved behaviour was characterized with step tracer experiments. Overlapping signals in online spectra during thiol-ene coupling could be deconvoluted with a spectral model using indirect hard modeling and were subsequently converted to either molar ratios (using a calibrationfree approach) or absolute concentrations (using 1-point calibration). For various solvents the kinetic constant k for pseudo-first order reaction was estimated to be 3.9 h-1 at 25 °C. The obtained results were compared with direct integration of non-overlapping signals and showed good agreement with the implemented mass balance.
Currently, research in chemical manufacturing moves towards flexible plug-and-play approaches focusing on modular plants, capable of producing small scales on-demand with short down-times between individual campaigns. This approach allows for efficient use of hardware, a faster optimization of the process conditions, and thus, an accelerated introduction of new products to the market. Driven mostly by the search for chemical syntheses under biocompatible conditions, so-called “click” chemistry rapidly became a growing field of research. The resulting simple one-pot reactions are so far only scarcely accompanied by an adequate optimization via comparably straightforward and robust analysis techniques.
Here we report on a fast and reliable calibration-free online high field NMR monitoring approach for technical mixtures. It combines a versatile fluidic system, continuous-flow measurement with a time interval of 20 s per spectrum, and a robust, automated algorithm to interpret the obtained data. All spectra were acquired using a 500 MHz NMR spectrometer (Varian) with a dual band flow probe having a 1/16-inch polymer tubing working as a flow cell. Single scan 1H NMR spectra were recorded with an acquisition time of 5 s, relaxation delay of 15 s. As a proof-of-concept, the thiol-ene coupling between N-boc cysteine methyl ester and allyl alcohol was conducted in non-deuterated solvents while its time-resolved behaviour was characterised with step tracer experiments.
Through the application of spectral modeling the signal area for each reactant can be deconvoluted in the online spectra and thus converted to the respective concentrations or molar ratios. The signals which were suitable for direct integration were used herein for comparison purposes of both methods.
Currently research in chemical manufacturing moves towards flexible plug-and-play approaches focusing on modular plants, capable of producing small scales ondemand with short down-times between individual campaigns. This approach allows for efficient use of hardware, a faster optimization of the process conditions, and thus, an accelerated introduction of new products to the market. Driven mostly by the search for chemical syntheses under biocompatible conditions, so-called “click” chemistry rapidly became a growing field of research. The resulting simple one-pot reactions are so far only scarcely accompanied by an adequate optimization via comparably straightforward and robust analysis techniques. Here we report on a fast and reliable calibration-free online high field NMR monitoring approach for technical mixtures. It combines a versatile fluidic system, continuous-flow measurement with a time interval of 20 s per spectrum, and a robust, automated algorithm to interpret the obtained data. All spectra were acquired using a 500 MHz NMR spectrometer (Varian) with a dual band flow probe having a 1/16 inch polymer tubing working as a flow cell. Single scan 1H spectra were recorded with an acquisition time of 5 s, relaxation delay of 15 s. As a proof-of-concept, the thiol-ene coupling between N-boc cysteine methyl ester and allyl alcohol was conducted in non-deuterated solvents while its time-resolved behaviour was characterised with step tracer experiments Through the application of spectral modeling the signal area for each reactant can be deconvoluted in the online spectra and thus converted to the respective concentrations or molar ratios. The signals which were suitable for direct integration were used herein for comparison purposes of both methods.