Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (17)
- Beitrag zu einem Tagungsband (3)
- Beitrag zu einem Sammelband (1)
- Vortrag (1)
- Posterpräsentation (1)
Sprache
- Englisch (23) (entfernen)
Schlagworte
- Pitting corrosion (7)
- Corrosion (6)
- Stainless steel (6)
- Atmospheric corrosion (4)
- KorroPad (4)
- Korrosion (4)
- Nichtrostender Stahl (4)
- Passive layer (4)
- Duplex stainless steels (3)
- Stress corrosion cracking (3)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (1)
In general, pH-sensitive colorants such as phenolphthalein are applied on freshly split surfaces of building structures to determine the state of carbonation. For years, it has been known that the aerosols of phenolphthalein are suspected of being carcinogenic. Hence, more work has currently being done on alternative indicators for the use in research and the use on construction sites. Over the past years, mainly pH indicators from other research areas and natural dyes were investigated for their usability to cementitious systems. This paper presents the experimental results of using phenolphthalein solution bound in agar-agar gel. This gel-bound indicator allows the future use of the already known phenolphthalein dye without the health hazards for the user. To demonstrate the flexibility of the gel-bound colorant, different application forms of the indicator were carried out and assessed. In addition, the results obtained by the different methods were statistically evaluated to ensure validity.
The accuracy of the results was confirmed by thermogravimetric analysis and IR spectroscopic studies as reference methods. It has also succeeded to demonstrate the comparability of the results achieved by the gel-bound colorant with the results of the common sprayed application method. As an additional gain in knowledge, comparative results of indicator tests, TGA analysis, and FTIR investigation are shown.
Modelling of reinforcement corrosion - Influence of concrete technology on corrosion development
(2006)
Reinforcement corrosion is influenced by different parameters like resistivity of concrete, setting conditions and also by concrete technology. Moreover the presence of cathodic areas and the possibility of unhampered cathodic reaction influences the reinforcement corrosion. In this paper the development of corrosion without large cathodic areas, called self-corrosion, considering different concrete parameters, is studied.
In order to clarify under which practical conditions real risks for hydrogen-induced stress corrosion cracking of prestressing steels exist laboratory investigations in aqueous solutions and concrete as well as tests with stressed prestressing steels were carried out. While different distances between steel and zinc (cathode and anode) showed only a negligible influence on the polarisation of the steel a significant dependence on the area ratio steel/zinc was observed. A critical area ratio of 10:1 can be defined above which polarisation of the steel to hydrogen evolution potentials is unlikely. The results obtained in the laboratory concerning the critical area ratio were confirmed by on-site investigations in a precasting plant. Exposure tests with hydrogen loading did not lead to fractures during the testing time for approved prestressing steels. The characteristic mechanical values determined immediately after the hydrogen loading tests did not show significant changes. Thus, an indirect contact between prestressing steels and galvanised elements can be estimated as uncritical. But a direct contact has to be excluded by compliance with DIN 1045-1, i.e minimal distance of 2 cm between prestressing steel and galvanised elements.
Risk of stress corrosion cracking of prestressing steels in contact with galvanized components
(2010)
The second part of this paper looks continues the comparative investigation of lean duplex stainless steels, manganese alloyed austenitic and duplex stainless steels and ferritic stainless steels. These new materials were investigated in many different test procedures and in different conditions focused on the application in civil engineering and common use. In addition to electrochemical investigations, all materials were exposed to atmospheric conditions in different surface states. In Part 2, Prof. Gümpel and his team examine the effects of coastal and urban atmospheres on the samples, and presents their final conclusions.
Systematic laboratory and field exposure tests allow to compare nine different stainless steels (three ferritic, three austenitic, and three duplex grades) for civil engineering applications. The influence of surface finish was also taken into account by choosing five different industry-specific features. The three duplex stainless steels revealed excellent corrosion resistance under most of the test conditions. Especially for applications in civil engineering the lean duplex steels offer distinct advantages. The manganese-alloyed 1.4376 and the ferritic steel 1.4509 cannot be recommended as alternative materials as they did not perform satisfactorily.
Pitting corrosion is one of the most common mechanisms of local passivity breakdown on stainless steels. Electrochemical methods have preferentially been applied for the evaluation of pitting corrosion resistance of stainless steels in laboratory. Nevertheless, some of them are not reliable enough and in general the application of electrochemical methods in the field becomes difficult because of a required deep understanding of corrosion phenomena and measurement technology. A new approach for the evaluation of the pitting corrosion susceptibility of stainless Steel surfaces in the laboratory as well as in the field is frequently demanded by representatives of the metalworking industry. Therefore, the KorroPad-test was invented and patented as part of a research project at the BAM Federal Institute for Materials Research and Testing in Germany.
Nine different stainless steel alloys were exposed for 5 years under marine environment and their corrosion behaviour was compared and assessed. The investigation of four different surface finishes for all alloys tested further enabled to consider industry-specific features of the surface finish for the material comparison. The results of the exposure tests yield conclusions regarding the influence of alloy composition, surface finish and exposure duration under marine environment. The three duplex stainless steels revealed excellent corrosion resistance even in case of crevices during the 5 years of exposure under the given exposure conditions. Also the molybdenum-alloyed ferritic steel 1.4521 showed good corrosion resistance comparable to the classical austenitic materials 1.4301 and 1.4404.
Pitting corrosion is one of the most common mechanisms of surface damage on stainless steels. Electrochemical methods have been preferentially applied for the evaluation of the pitting corrosion resistance of stainless steels in the laboratory. Nevertheless, some of them are not reliable enough and in general the application of electrochemical methods in the field becomes difficult because of required deep understanding of corrosive phenomena and measurement technology. Therefore, new approaches for the evaluation of the pitting corrosion susceptibility of stainless steel surfaces in the laboratory as well as in the field are necessary. In the present paper two novel strategies including electrochemical noise measurements under anodic polarization for laboratory testing, and an indicator test to assess the susceptibility of stainless steel surfaces to pitting corrosion in the field are introduced. Experimental results concerning the influence of surface treatments on the pitting corrosion resistance on stainless steels have confirmed that final surface condition has a significant effect on their future pitting corrosion susceptibility. In addition, the pitting corrosion resistance of stainless steel surfaces was observed being specifically dependent on the achieved surface topography and in some cases independent on the roughness parameters of the surface.