Filtern
Erscheinungsjahr
- 2012 (15) (entfernen)
Dokumenttyp
- Zeitschriftenartikel (4)
- Beitrag zu einem Tagungsband (4)
- Vortrag (4)
- Beitrag zu einem Sammelband (1)
- Dissertation (1)
- Posterpräsentation (1)
Schlagworte
- Crack propagation (2)
- Crack resistance (2)
- Elastomer (2)
- Fracture mechanics (2)
- Fracture toughness (2)
- Plastics (2)
- (U)HMW-PE (1)
- Acoustic propagation (1)
- Cask for storage and transport of radioactive materials (1)
- Compression set (1)
- Cross linked polyethylene insulation (1)
- Crosslinking (1)
- Curemeter (1)
- DSC (1)
- Dichtung (1)
- Dynamic mechanical analysis (1)
- EVA (1)
- Ethylene vinyl acetate (1)
- Gamma irradiation (1)
- Glas-Gummi-Übergang (1)
- Leckagerate (1)
- Low temperature behaviour (1)
- Mechanical variables measurement (1)
- Rheology (1)
- Sealing material (1)
- Shielding material (1)
- Silicone rubber (1)
- Tieftemperaturverhalten (1)
- Ultrasound (1)
- glass-rubber transition (1)
- leakage rate (1)
- low temperature behavior (1)
- seal, rubber (1)
Eingeladener Vortrag
- nein (4)
Tieftemperaturverhalten und Alterung von Elastomerdichtungen - Aktuelle Tätigkeiten und Ziele
(2012)
Fracture mechanics approaches are increasingly applied for the characterization of epoxy resin and adhesive mechanical properties. Therefore, the fracture toughness and crack resistance under static load ISO 13586 [1] are often regarded as state of the art to analyse material improvements. However, experimental investigations on fatigue behaviour, thus the crack propagation according to ISO 15850 [2], seem to be much more sensitive to characterize the materials for in service loading conditions. Firstly, an efficient testing concept was developed at BAM. In this framework, the geometry for a modified single edge notched tensile specimen (SET) was developed in order to assure appropriate resolution in measuring the crack length via a CCD-camera [3]. In the next step, the influence of the cure temperature on the fracture-mechanical properties was investigated.
Partial discharges may cause damage to electrical insulation of high voltage equipment. They initiate elastic waves in the insulating material, e.g. in the stress cone of an outdoor termination. Localisation of the origin of such elastic waves can help to predict serious damaging processes in the electrical insulation. In order to measure and evaluate the wave propagation effects in typical multilayered elastomeric structures, knowledge of the material properties is required. The propagating velocity and the attenuation of longitudinal waves are important parameters. Values for these quantities found in the literature were not appropriate. Therefore, for cross-linked polyethylene (XLPE) and cured liquid silicone rubber (LSR), the longitudinal wave velocity and the attenuation were evaluated in the temperature interval from -20°C to 50°C and in the frequency range from 200 kHz to 600 kHz using a two-sample ultrasound technique. The loss factor was determined from these measured quantities. Additionally, low frequency Dynamic Mechanical Thermal Analysis (DMTA) was applied to investigate LSR and XLPE in a temperature interval between -100 and 50°C and to check qualitatively the ultrasound data.