Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (99)
- Beitrag zu einem Tagungsband (36)
- Beitrag zu einem Sammelband (18)
- Forschungsbericht (4)
- Vortrag (1)
- Sonstiges (1)
- Posterpräsentation (1)
Sprache
- Englisch (160) (entfernen)
Schlagworte
- POD (12)
- Reliability (9)
- Glass (7)
- LTCC (6)
- X-ray refraction (6)
- XPS (6)
- Dye (5)
- Quantum yield (5)
- Viscosity (5)
- AIE (4)
Organisationseinheit der BAM
- 5 Werkstofftechnik (16)
- 5.6 Glas (16)
- 8 Zerstörungsfreie Prüfung (13)
- 6 Materialchemie (11)
- 8.5 Röntgenbildgebung (11)
- 1 Analytische Chemie; Referenzmaterialien (10)
- 6.1 Oberflächen- und Dünnschichtanalyse (7)
- 1.2 Biophotonik (6)
- 4 Material und Umwelt (4)
- 6.5 Synthese und Streuverfahren nanostrukturierter Materialien (3)
Eingeladener Vortrag
- nein (1)
Im Zuge der Anwendung des Schadens-Toleranz-Prinzips wird ein adäquates zerstörungsfreies Prüfsystem benötigt um strukturelle Integrität sicher zu stellen. Wenn ein zerstörungsfreies Prüfsystem jedoch bis zu den Grenzen der Detektionsfähigkeit beansprucht wird, liefert es keine übereinstimmende Indikationen der Defektentdeckung (Hit/Miss). Deshalb wird dessen Fähigkeit Defekte zu entdecken als Entdeckungswahrscheinlichkeit (POD Probability of Detection) ausgedrückt. In der herkömmlichen 'Signal Response' Signal-Antwort-Zuverlässigkeitsanalyse wird die Entdeckungswahrscheinlichkeit als eine Funktion der Defektgröße angegeben. Die Eignung des Prüfsystems wird durch den Vergleich der Größe des Defektes, der zuverlässig entdeckt wird, mit der des größten zulässigen Defektes, der die strukturelle Integrität nicht gefährdet, verifiziert. Analysen moderner Strukturen zeigen aber, dass auch andere Parameter den Schweregrad des Defektes bzgl. der Integrität der Struktur bestimmen können. Im Rahmen der Multi-Parameter-Zuverlässigkeitsanalyse kann die Entdeckungswahrscheinlichkeit als eine Funktion verschiedener Einflussparameter ausgedrückt werden. Wenn die Eignung des zerstörungsfreien Prüfsystems bestimmt wird, muss die Fähigkeit des Systems Defekte zu entdecken gegenüber dem kritischen Wert genau des Parameters ausgedrückt und geprüft werden, der den Schweregrad des Defektes für die Integrität der Struktur bestimmt. Die Nichterfüllung dieser Forderung kann zur Ablehnung von intakten Teilen oder der Akzeptanz von schlechten Teilen führen. Das Prinzip wird anhand von longitudinalen Ultraschall-Sende-Empfangs-Prüfdaten der Gußeisenmatrix mit oberflächenoffenen, semi-elliptischen, rißartigen Defekten demonstriert.
Das Ziel des Artikels ist es eine Übersicht über neue methodische Ansätze und Verfahren zur Bewertung der Zuverlässigkeit von ZfP-Systemen in Übereinstimmung mit den spezifischen Anforderungen verschiedener industrieller Anwendungen zu geben. Nach einem Überblick über die in den vergangenen Jahrzehnten erreichten Fortschritte, wird der Fokus auf die gegenwärtigen Entwicklungen gerichtet. Für hohe Sicherheitsanforderungen wurde die quantitative Fehlerauffindwahrscheinlichkeit (probability of detection, POD) basierend auf 'hit/miss'- oder 'Signal-Response'-Analysen und die ROC-Analyse (Receiver Operating Characteristics) als typische Werkzeuge entwickelt. Im Rahmen des modularen Modells für die ZfP-Zuverlässigkeit unterscheidet man zwischen den rein physikalisch-technischen Einflussfaktoren, den industriellen Anwendungsfaktoren und den menschlichen Faktoren. Es hilft zum Beispiel zu erkennen, welche dieser Faktoren man in Modellierungsrechnungen bzw. mittels offenen oder Blindversuchen untersuchen kann. Ein neues Paradigma wird für die Betrachtung der POD als eine Funktion der gewählten Systemparameter und somit als Optimierungswerkzeug verwendet, anstelle sie für die endgültige Beurteilung zu nehmen. Zur Handhabung der Zuverlässigkeitsuntersuchung von realen Defekten in einer realistischen Umgebung werden ökonomisch vertretbare, aber dennoch präzise genug arbeitende Methoden, wie der Ansatz von Bayes oder modellbasierte Methoden vorgestellt. Die menschlichen Faktoren sind oft von ausschlaggebender Wichtigkeit für die Gesamtzuverlässigkeit. Hier hilft ein systematischer psychologischer Ansatz die Engpässe und Verbesserungsmöglichkeiten zu finden.
In a systematic approach we synthesized a new series of fluorescent probes incorporating donor–acceptor (D-A) substituted 1,2,3-triazoles as conjugative π-linkers between the alkali metal ion receptor N-phenylaza-[18]crown-6 and different fluorophoric groups with different electron-acceptor properties (4-naphthalimide, meso-phenyl-BODIPY and 9-anthracene) and investigated their performance in organic and aqueous environments (physiological conditions). In the charge-transfer (CT) type probes 1, 2 and 7, the fluorescence is almost completely quenched by intramolecular CT (ICT) processes involving charge-separated states. In the presence of Na+ and K+ ICT is interrupted, which resulted in a lighting-up of the fluorescence in acetonitrile. Among the investigated fluoroionophores, compound 7, which contains a 9-anthracenyl moiety as the electron-accepting fluorophore, is the only probe which retains light-up features in water and works as a highly K+/Na+-selective probe under simulated physiological conditions. Virtually decoupled BODIPY-based 6 and photoinduced electron transfer (PET) type probes 3–5, where the 10-substituted anthracen-9-yl fluorophores are connected to the 1,2,3-triazole through a methylene spacer, show strong ion-induced fluorescence enhancement in acetonitrile, but not under physiological conditions. Electrochemical studies and theoretical calculations were used to assess and support the underlying mechanisms for the new ICT and PET 1,2,3-triazole fluoroionophores.
The internal friction of hydrated soda-lime-silica glasses with total water content (CW ) up to 1.9 wt. % was studied by dynamic mechanical analysis (DMA) using temperature-frequency sweeps from 723 K to 273 K and from 1 s-1 to 50 s-1. Total water content and concentrations of H2O molecules (CH2O ) and OH groups (COH) in the DMA specimens were determined by infrared spectroscopy. For low water contents (CW ≈ COH < 0.25 wt. %) two discrete internal friction peaks below the glass transition (α relaxation) were assigned to the low-temperature motion of alkali ions (γ relaxation) and cooperative movements of dissimilar mobile species under participation of OH at higher temperature (βOH relaxation). For large water contents (CW > 1 wt. %), where significant amounts of molecular water are evident (CH2O > 0.15 wt. %), however, internal friction spectra change unexpectedly: the βOH peak heights saturate and a low temperature shoulder appears on the β-relaxation peak. This emerging relaxation mode (βH2O relaxation) was assigned to the motions of H2O molecules. βH2O relaxation was found to be faster than βOH but slower than γ relaxation. Activation energy of the different relaxation modes increased in the order γ < βH2O < βOH < α.
POD is the most often used approach for the evaluation of the reliability of non-destructive testing methods in critical areas. But especially for those cases the requirements for a sufficient amount of data, adequate type of defects and the statistical requirements are high. The claim for checking these requirements is not new, but never the less often ignored. Especially the large amount of data for critical real defects seems too often to be not really solvable. In this presentation we show an approach to use real defect data with knowledge from former testing results with the same equipment, in a useful adequate way. Furthermore we introduce a method to evaluate the real defect description parameters for the radiographic testing. This approach was used for a joint project with the company POSIVA, which is building a final depository for spent nuclear fuel in Finland. Radiographic testing is one of the NDT-methods they use to test the electron beam weld of the copper canister. The copper canister will be used in the deposit as a corrosion barrier within the deposit concept. Through the high sophisticated manufacturing methods of the canister there are almost no material defects, which could be used for reliability evaluation. In this context the idea of Bayesian Updating of the POD with real defect data with former results from artificial defect data was born to get a useful evaluation.
Using the Modular Reliability Model the three different main influencing elements, i.e. intrinsic capability (IC), application parameters (AP) and the human factors (HF), are, in the first instance, investigated separately. The intrinsic capability stands for the pure physical-technological process of the signal detection caused by the waves or the rays from a material defect in the presence of noise (driven by the material and the devices). This intrinsic capability is the upper bound of the possible reliability. Already when measuring this intrinsic capability for thick walled components the original one-parameter POD must be extended to a multiparameter POD, where, in addition to the defect size, a number of additional physical parameters, such as the grain size distribution (or attenuation), defect depth, and angle or surface roughness, must be considered. For real life cycle assessments it is necessary to evaluate the signal response from real defects. The industrial application factors, e.g. coupling conditions, limited accessibility, heat and environmental vibrations, diminish the reliability. The amount of reduction can be determined quantitatively, if the underlying conditions are controlled. In case they are not controlled it is necessary to count for a fluctuation in the reliability in the field anyway. The third group of important influencing factors are the human factors, which do not only cover the individual performance capability of the inspectors but also the design of the working place,the procedure, the teamwork quality, interaction with systems, the organization, and finally, the relationship between the companies involved in the inspection process and to which extend the responsible parties are aware of it. When comparing an “ideal inspection” with a “real inspection” it is worth while to look how the existing practices, rules and standards support reliable testing and where the “delta” is. In the context of vigor, with respect to the industrial end user, it needs to be shown how the level of reliability of NDE, influenced by the different factors, has an impact on acceptance or rejection of safety critical parts.
Investigation of fuel cell materials and liquid water transport by means of synchrotron imaging
(2013)
Synchrotron imaging allows addressing various important issues in fuel cell research, for example water distribution and transport. The water distribution in polymer electrolyte membrane fuel cells (PEMFCs) was observed quasi in-situ directly after operation by means of synchrotron tomography. The 3D data set was compared with the tomogram of a dry cell in order to separate the water distribution from cell materials. Engineered transport pathways realized by perforating holes through the gas diffusion layer (GDL) are a recent approach to optimize water transport and cell performance. For some parameter sets a cell performance increase and an improvement of stabilization have already been proven. We present high resolution investigations of the water distribution in perforated GDLs of operating PEMFCs by means of in-situ synchrotron radiography. The surrounding areas of the holes exhibited a distinct hydrophilic character.
The production of agglomerate-free SiO2 particles exhibiting a monomodal distribution of particle sizes of around 300 nm by means of direct laser fuming of micrometric SiO2 powders has been successfully demonstrated. With a 12 kW cw CO2 laser system, a production rate of up to 1 kilogram powder per hour was achieved. Almost ideal spherical amorphous SiO2 particles in a broad particle size distribution between 10 nm and several 100 nm (d50 ≈ 300 nm) were synthesized. Several observations suggest weak agglomeration forces between the particles. A temperature reduction of 200 °C for sintering powder compacts was observed.
The report 'Probability of Defect Detection of Posiva's electron beam weld' describes POD curves of four NDT methods radiographic testing, ultrasonic testing, eddy current testing and visual testing. POD-curves are based on the artificial defects in reference blocks. The results are devoted to the demonstration of suitability of the methods for EB weld testing. Report describes methodology and procedure applied by BAM.
Report creates a link from the assessment of the reliability and inspection performance to the risk assessment process of the canister final disposal project. Report ensures the confirmation of the basic quality of the NDT methods and their capability to describe the quality of the EB-weld.
The probability of detection curves are determined based on the MIL-1823 standard and it's reliability guidelines. The MIL-1823 standard was developed for the determination of integrity of gas turbine engines for the US military.
In the POD-process there are determined as a key parameter for the defect detectability the a90/95 magnitudes, i.e. the size measure a of the defect, for which the lower 95 % confidence band crosses the 90 % POD level. By this way can be confirmed that defects with a size of a90/95 will be detected with 90 % probability. In case the experiment will be repeated 5 % might fall outside this confidence limit.
We present a synchrotron X-ray tomographic study on the morphology of carbon fiber-based gas diffusion layer (GDL) material under compression. A dedicated compression device is used to provide well-defined compression conditions. A flat compression punch is employed to study the fiber geometry at different degrees of compression. Transport relevant geometrical parameters such as porosity, pore size and tortuosity distributions are calculated. The geometric properties notably change upon compression which has direct impact on transport conditions for gas and fluid flow. The availability of broad 3D paths, which are most important for the transport of liquid water from the catalyst layer through the GDL, is markedly reduced after compression. In a second experiment, we study the influence of the channel-land-pattern of the flow-field on shape and microstructure of the GDL. A flow-field compression punch is employed to reproduce the inhomogeneous compression conditions found during fuel cell assembly. While homogenously compressed underneath the land the GDL is much less and inhomogeneously compressed under the channel. The GDL material extends far into the channel volume where it can considerably influence gas and fluid flow. Loose fiber endings penetrate deeply into the channel and form obstacles for the discharge of liquid water droplets.
The H2 effusion from H2 saturated glass powders, H2 permeation through the wall of blown glass bulbs, and H2 permeation through the wall of glass capillaries were applied to evaluate the permeability of hydrogen gas in a barium-aluminoborosilicate (BABS) glass. To validate these methods, two commercial glasses (vitreous silica and borosilicate) were used as a reference. Permeation values obtained from the different experiments agreed within a factor of 3 or less. The H2 permeability of BABS glass at temperatures close to ambient was found to be at least 3 orders of magnitude below that of borosilicate and silica glasses. The powder method, which requires minimal sample preparation efforts, turned out to provide easy access to the measurement of H2 permeability of glasses down to P = 3.9 × 10- 21 mol s- 1 Pa- 1 m- 1.
Since the beginnings of the European American Workshops (EAW) in 1997, the aim was to gather the experts in NDE reliability and discuss burning topics with the aim of identifying crucial problems and suggesting ways to move forward. This was usually achieved during the so-called break-out sessions, in which predetermined topics were discussed. During the 5th EAW, held in Berlin in 2013, this approach was replaced by an Open Space Technology (OST) approach. The benefit of this approach is seen in the freedom of topic choices, i. e., the topics are not predetermined but rather arise at that moment in that space and by the participants choice. The following topics arose: new reliability methods (Bayesian, MAPOD,
), structural health monitoring, definition of requirements of NDE by customer versus provider, what value of POD is good enough?, human factors, manual versus automated inspection, and basic concepts of reliability of NDE. The participants were encouraged to walk from one session to another and openly express their opinions. These were in the end summarized by a chosen group of moderators and presented in this paper.
Forest fires start mostly in partial combustion. In this paper we present a hydrogen sensor to defect early stages of forest fires. First indoor experiments in a smoke density chamber with wood samples, proved that the sensor produce a strong signal change when the smouldering of wood starts, already before the CO concentration, measured in FTIR spectrometry, exceeds 10 ppm. In outdoor experiments we were able to detect forest fire in a distance of 110 m.
The inspection of the sealing weld is an important phase for the evaluation of the acceptability of final disposal canister, but the weld is only a part of the 3D shielding of copper shell. The main tasks for reliable NDT evaluation requires an extensive evaluation of the parameters which contains typical inspection related items like repeatability, S/N ratio, POD, setting up the equipment for inspection, and all practices for inspections. The other parameters are material parameters, their variation must be taken into account in the evaluation of NDT reliability. Further parameters include human factors, i. e. human inspectors and their interaction with technical systems; their effects were studied on an example of the evaluation of eddy current data. Final parameters are related to evaluation of detected defects, which means sizing and base for acceptance and this can be done in different ways. Some examples are given and results are compared with different methods for instance between radiographic testing and ultrasonic testing by raw data analysis and PA-SAFT results. Also, preliminary curves for the evaluation of metallographic results of 55 defects will be shown by EB weld measurements. Some practical items concerning copper inspections will be also discussed related to acceptability.
Bispidines for dual imaging
(2014)
The efficient transformation of the hexadentate bispidinol 1 into carbamate derivatives yields functional bispidines enabling convenient functionalization for targeted imaging. The BODIPY-substituted bispidine 3 combines a coordination site for metal ions, such as radioactive 64CuII, with a fluorescent unit. Product 3 was thoroughly characterized by standard analytical methods, single crystal X-ray diffraction, radiolabeling, and photophysical analysis. The luminescence of ligand 3 was found to be strongly dependent on metal ion coordination: CuII quenches the BODIPY fluorescence, whereas NiII and ZnII ions do not affect it. It follows that, in imaging applications with the positron emitter 64CuII, residues of its origin from enriched 64Ni and the decay products 64NiII and 64ZnII, efficiently restore the fluorescence of the ligand. This allows for monitoring of the emitted radiation as well as the fluorescence signal. The stability of the 64CuII–3 complex is investigated by transmetalation experiments with ZnII and NiII, using fluorescence and radioactivity detection, and the results confirm the high stability of 64CuII–3. In addition, metal complexes of ligand 3 with the lanthanide ions TbIII, EuIII, and NdIII are shown to exhibit emission of the BODIPY ligand and the lanthanide ion, thus enabling dual emission detection.
The present study is dealing with the basic physics for a novel way to generate a free-formed ceramic body, not like common layer by layer, but directly by Selective Volume Sintering (SVS) in a compact block of ceramic powder. To penetrate with laser light into the volume of a ceramic powder compact it is necessary to investigate the light scattering properties of ceramic powders. Compared with polymers and metals, ceramic materials are unique as they offer a wide optical window of transparency. The optical window typically ranges from below 0.3 up to 5 µm wave length. In the present study thin layers of quartz glass (SiO2) particles have been prepared. As a function of layer thickness and the particle size, transmission and reflection spectra in a wave length range between 0.5 and 2.5 µm have been recorded. Depending on the respective particle size and by choosing a proper relation between particle size and wave length of the incident laser radiation, it is found that light can penetrate a powder compact up to a depth of a few millimeters. With an adjustment of the light absorption properties of the compact the initiation of sintering in the volume of the compact is possible.