Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (113)
- Beitrag zu einem Tagungsband (45)
- Beitrag zu einem Sammelband (29)
- Forschungsbericht (9)
- Posterpräsentation (3)
- Vortrag (2)
- Sonstiges (1)
Schlagworte
- POD (15)
- Geruch (10)
- Reliability (9)
- Bauprodukte (8)
- Glass (7)
- Emissionen (6)
- LTCC (6)
- VOC (6)
- X-ray refraction (6)
- XPS (6)
Organisationseinheit der BAM
- 5 Werkstofftechnik (16)
- 5.6 Glas (16)
- 6 Materialchemie (11)
- 8 Zerstörungsfreie Prüfung (11)
- 1 Analytische Chemie; Referenzmaterialien (10)
- 8.5 Röntgenbildgebung (9)
- 6.1 Oberflächen- und Dünnschichtanalyse (7)
- 1.2 Biophotonik (6)
- 4 Material und Umwelt (5)
- 6.5 Synthese und Streuverfahren nanostrukturierter Materialien (3)
Eingeladener Vortrag
- nein (2)
The applicability of excimer laser at 308 nm and Nd:YAG laser at 532 nm with fluences below 0.86 J/cm2 for cleaning of cellulose and paper materials was evaluated. The extent of degradation of purified cotton cellulose and Fabriano paper after laser treatment as well as after a period of accelerated humid oven ageing was determined by following the changes in the degree of polymerization. While irradiation of paper with the excimer laser at 308 nm results in depolymerization of cellulose accompanied by a decrease in ISO brightness, no detrimental effects of Nd:YAG laser treatments were observed.
A comparison of different isotope dilution mass spectrometric (IDMS) procedures using inductively coupled plasma mass spectrometry (ICPMS) and thermal ionization mass spectrometry (TIMS) was carried out to examine the degree of equivalence between the used procedures in terms of requirements for reference material certification. The comparison was based on the measurement results and their uncertainties. The sample used in this study is a pure zinc metal to be certified by the Bureau Communie de Référence (BCR) for amount contents of different trace elements. This study focuses on cadmium and thallium. The TIMS values contributed to the certified values. To guarantee identical conditions as far as possible for the procedures under investigation, the samples were split into subsamples after spiking and digestion took place. Thus, every IDMS procedure started with an identical set of samples. In total, four different IDMS procedures and one external calibration procedure using internal standardization as an example of routine analysis were applied. The IDMS procedures divide in a group with and a group without trace/matrix separation. Multicollector TIMS (TI-MC-MS) and multicollector ICPMS (ICP-MC-MS) were used in combination with trace/matrix separation, whereas quadrupole ICPMS (ICP-QMS) and ICP-MC-MS were also applied to nonseparated samples. All IDMS results agree well within their combined uncertainties, while some results from the external calibration procedure do not. IDMS results obtained by ICPMS without separation are comparable to those obtained by TI-MC-MS with separation regarding precision and accuracy. The smallest uncertainties were achieved using ICP-MC-MS in combination with trace/matrix separation.
Das Basisanliegen - Einleitung
Mit der zunehmenden Zahl akkreditierter ZfP-Firmen und zunehmender Anwendung risikobasierender Konzepte ergibt sich die Notwendigkeit, internationale Standards wie die DIN EN ISO 17025 und darüber hinausgehende Richtlinien bei der Verfahrensauswahl in der ZfP zu berücksichtigen. Dieser Aufsatz soll aufzeigen, welche internationalen Aktivitäten gegenwärtig für die Zuverlässigkeitsbetrachtungen von Bedeutung sind (siehe auch [1]). In Übereinstimmung mit den Vereinbarungen und Definitionen der European-American Workshops zur Zuverlässigkeit [2, 3] gilt: Das Basisanliegen der Zuverlässigkeitsuntersuchungen beliebiger diagnostischer Systeme besteht darin, den Grad festzustellen mit dem das Prüfsystem in der Lage ist, seinen vorgesehenen Zweck zu erfüllen. Im Falle der ZfP besteht dieser Zweck zumeist in der Aufgabe, Bauteildefekte aufzufinden und zu beschreiben bzw. die Defektfreiheit von Bauteilen zu bestätigen, sowie Wanddicken zu messen oder Material zu charakterisieren.
Das Basisanliegen der Zuverlässigkeitsuntersuchungen findet seinen Niederschlag bei folgenden international relevanten Aktivitäten:
neue ISO 17025 als Notwendigkeit mit variablen Möglichkeiten der Verfahrensvalidierung
als Kettenglied in RBLM (Risk Based Life Time Management) (r) EPERC-Initiative
CEN/TC138/WG9 "Qualifizierung von ZfP-Verfahren"
Six-Sigma Strategie: als notwendiger Bestandteil
ASNT-Initiative: Standing Committee on NDE Reliability: als Arbeitspaket
Produkthaftung: als notwendige Voraussetzung für die Handhabung