The three-dimensional water distribution and water transport paths in the gas diffusion layer (GDL) and the adjacent micro-porous layer (MPL) of a polymer electrolyte membrane fuel cell (PEMFC) were analyzed during cell operation. The technique of quasi in-situ X-ray tomography was used for a 3D visualization of the water distribution and the structure of the GDL at different operating conditions. Based on findings from in-situ radiographic measurements water transport paths were detected and subsequently examined by tomography. The combination of these 2D and 3D techniques allows for a fully three-dimensionally resolved visualization of transport paths through the GDL.
Synchrotron X-ray radiography and tomography investigations of a custom-made polymer electrolyte membrane fuel cell optimised for visualisation purposes are presented. The 3D water distribution and transport pathways in the porous carbon fibre gas diffusion layers (GDLs) were investigated. The authors found that water is not only moving from the GDL into the channel, but can also take the opposite way, that is, from the channel into free pore space of the GDL. Such movement of water into the opposite direction has been subject of speculations but has so far not yet been reported and might bring new insights into the general water transport behaviour, which might give new aspects to the general description of water transport processes and influence modelling assumptions to describe the process taking place in the GDL.
Perforated gas diffusion layers (GDLs) of polymer electrolyte membrane fuel cells (PEMFCs) were investigated by means of in-situ synchrotron X-ray radiography during operation. We found a strong influence of perforations on the water distribution and transport in the investigated Toray TGP-H-090 GDL. The water occurs mainly around the perforations, while the holes themselves show varying water distributions. Some remain dry, while most of them fill up with liquid water after a certain period or might serve as drainage volume for effective water transport.
Investigation of fuel cell materials and liquid water transport by means of synchrotron imaging
(2013)
Synchrotron imaging allows addressing various important issues in fuel cell research, for example water distribution and transport. The water distribution in polymer electrolyte membrane fuel cells (PEMFCs) was observed quasi in-situ directly after operation by means of synchrotron tomography. The 3D data set was compared with the tomogram of a dry cell in order to separate the water distribution from cell materials. Engineered transport pathways realized by perforating holes through the gas diffusion layer (GDL) are a recent approach to optimize water transport and cell performance. For some parameter sets a cell performance increase and an improvement of stabilization have already been proven. We present high resolution investigations of the water distribution in perforated GDLs of operating PEMFCs by means of in-situ synchrotron radiography. The surrounding areas of the holes exhibited a distinct hydrophilic character.
Water evolution in the gas diffusion layer of a polymer electrolyte membrane fuel cell was visualized in situ by means of synchrotron X-ray radiography. Cracks in the microporous layer were identified as start points of efficient liquid water transfer paths through the gas diffusion layer. Quantitative analysis of the water flow rate through those arbitrarily distributed cracks into the gas channel revealed that they have a strong influence on the overall liquid water transport. This could find entry into future material design and simulation.
Isotope amount ratios of krypton were measured on subsamples from one large batch of high purity krypton separated from the atmosphere. Synthetic mixtures of enriched krypton isotopes were used to calibrate the measurements with small uncertainties. The result is a primary isotopic gas standard (PIGS) IRMM-2030 with certified values for isotope ratios, isotopic composition, and molar mass of krypton with small combined uncertainties uc, evaluated according to the ISO/BIPM Guide (GUM). It is commercially available from IRMM-Geel or from MESSER (Duisburg, D). The certified krypton isotope amount ratios in the PIGS IRMM-2030 are as follows: n(78Kr)/n(84Kr)=0.006 232 5(55), n(80Kr)/n(84Kr)=0.040 107(17), n(82Kr)/n(84Kr)=0.203 43(12), n(83Kr)/n(84Kr)=0.201 79(11), and n(86Kr)/n(84Kr)=0.303 205(59) with expanded uncertainty U=kuc and coverage factor k=2. The molar mass of Kr in this sample is M(Kr)=83.798 02(16) g/mol. These values are in good agreement with published measurements of atmospheric krypton but have smaller combined uncertainties and are calibrated by means of synthetic isotope mixtures. The values of the PIGS are traceable to the SI. Measurements of isotope amount ratios of krypton in other samples can be linked to SI using this PIGS.
Synchrotron X-ray absorption edge imaging was used to investigate the ruthenium distribution in both fresh and aged Pt/Ru-based membrane electrode assemblies (MEA) of direct methanol fuel cells. MEAs aged in different ways were analyzed: artificially aged by MeOH depletion and aged for 1700 h in an operating fuel cell stack. An element sensitive tomographic technique – differential X-ray absorption edge tomography – was applied allowing for a 3D-visualization of the ruthenium distribution within the MEA. We found a markedly changed Ru distribution after aging which is correlated to the GDL structure, the flow field geometry, and CO2 transport in the methanol solution.
Synchrotron X-ray absorption edge imaging with high energy resolution was applied to study aging of fuel cell catalyst materials. The combination of an imaging and a high X-ray energy resolution set-up allows acquiring spatially resolved XAS (XANES and EXAFS) spectra. We analyzed the two-dimensional distribution of Pt and Ru in fresh and aged fuel cell catalysts. Spatially resolved XAS images were taken at the RuK edge and at the PtL3 edge. Taking radiographs above and below the absorption edges provides quantitative information about the thickness of the catalytic materials and additional chemical information. A strong influence of the flow field channels and the structure of the gas diffusion layers on the thicknesses of the catalytic elements were found: a thinner catalyst layer was found below the ribs of the flow field geometries as well as under crossing points of fiber bundles of the woven gas diffusion layers.
In contrast to classical low temperature polymer electrolyte fuel cells (LT-PEFCs), the membrane conductivity in high temperature polymer electrolyte fuel cells (HT-PEFCs) (operating temperature ~ 160 °C) is based on proton transport within phosphorus-oxygen acids at different levels of hydration, orthophosphoric acid (H3PO4) being the simplest example. We present for the first time in-situ synchrotron X-ray radiography measurements applied to a HT-PEFC to gain insight into the local composition of the membrane electrode assembly (MEA) under dynamic operating conditions. Transmission changes during the radiographic measurements exhibit a clear influence of the formation of product water on the membrane composition.
The carbon dioxide evolution and bubble formation in an operating fuel has been studied by means of synchrotron X-ray radiography. Two different observation directions have been chosen: a through-plane insight has been employed to track the formation of bubbles starting at the corner of the lands of the flow field; a depth profile of the carbon dioxide evolution has been derived from cross sectional studies describing an affected area of up to 100 µm. The dynamics of the bubble formation and detachment of the bubbles from the position of formation is strongly correlated with the current density. Cracks and breaks in the catalyst layer which result from the preparation process are visible under operating conditions and a possible swelling of the catalyst layer does not reach a complete vanishing of the cracks.
Influence of artificial aging of gas diffusion layers on the water management of PEM fuel cells
(2014)
The influence of artificial aging of gas diffusion layers (GDL) on the water management within the GDL was investigated in-operando by synchrotron X-ray radiography. One GDL was subjected to an accelerated aging procedure in 30% H2O2 solution, while another GDL was pristine. Radiographic measurements were combined with temporally resolved electrical analyzes. Significant differences in cell voltage and water accumulation were observed during cell operation at steady-state conditions. The cell which contained the aged GDL featured a higher water amount especially at the anode side and a lower cell voltage.
Laser-fused K0.5Na0.5NbO3 (KNN) powder of 75% transparent fraction has been sintered by pressureless sintering, spark plasma sintering (SPS), and hot isostatic pressing (HIP). The laser-fused KNN has a fictive temperature of 503 °C and an onset crystallization temperature of around 529 °C. The results have shown that sintering of the laser-fused KNN powder utilizing the viscous flow of the transparent microspheres (amorphous content)–at the kinetic window (26 °C)–is possible. The highest yield relative density is around 83% at a sintering temperature of 525 °C and at a sintering pressure of 280 MPa. Limited density has been reached because of formation of crystalline surface layers around the amorphous areas. The samples hipped at 525 °C have low piezoelectric coefficient d33 of 5 pC/N because of the residual porosity that led to early dielectric breakdown during the polarization. The sintering behavior, the resulting microstructure as well as the measured properties will be discussed.
In this investigation, synchrotron X-ray imaging was used to investigate the water distribution inside newly developed gas diffusion media in polymer electrolyte membrane fuel cells. In-situ radiography was used to reveal the relationship between the structure of the microporous layer (MPL) and the water flow in a newly developed MPL equipped with randomly arranged holes. A strong influence of these holes on the overall water transport was found. This contribution provides a brief overview to some of our recent activities on this research field.
This key comparison aims to assess the core capabilities of the participants in gas analysis. Such competences include, among others, the capabilities to prepare Primary Standard gas Mixtures (PSMs), perform the necessary purity analysis on the materials used in the gas mixture preparation, the verification of the composition of newly prepared PSMs against existing ones, and the capability of calibrating the composition of a gas mixture. According to the Strategy for Key Comparisons of the Gas Analysis Working Group, this key comparison is classified as an RMO track A key comparison.
The artefacts were binary mixtures of propane in nitrogen at a nominal amount-of-substance fraction level of 1000 μmol/mol. The values and uncertainties from the gravimetric gas mixture preparation were used as key comparison reference values (KCRVs). Each transfer standard had its own KCRV. The results are generally good. All results are within ± 1 % of the KCRV.
CCQM-K118 was an international key comparison on natural gas composition with two types of gases, i.e., a low calorific hydrogen-enriched natural gas and a high calorific LNG type of gas. There were 14 participating laboratories. The traveling standards (i.e., 14 mixtures each) were obtained from an external source and checked for homogeneity and stability before and after the participants' measurements at the two coordinating laboratories. The data evaluation was performed using a consensus value and a laboratory effect model. The results of the participants were benchmarked against a key comparison reference value computed from the largest consistent subset (LCS) of the submitted results, adjusted for the differences between the travelling standards. For the first time in a key comparison in gas analysis, the model included a term to account for excess variability in the LCS. Most of the participants reported one or a few (slightly) discrepant results. Partly this is due to the heterogeneity and heteroscedasticity of the datasets. In all, the results in this key comparison demonstrate the good comparability of the national measurement standards for natural gas composition maintained by the participating NMIs.
Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.
The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/.
The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Coordination chemistry was applied to deposit pyridine-functionalized gold nanoparticles on silicon substrates. The particles were synthesized through the Brust/Schiffrin route with a subsequent ligand exchange reaction yielding well-defined particles of two different sizes. Multilayer deposition was carried out on a pyridine-terminated SAM, anchored on a hydroxyl-terminated silicon surface. Analogously, Hunter/Vögtle-type tetralactam macrocycle multilayers were deposited as well as mixed layers containing both either in an alternating sequence or as a macrocycle multilayer with a terminating nanoparticle layer. These composite layers were examined with respect to their ability to bind squaraine axles in the macrocycle cavities. The amount of guest bound is higher for the composite layer with alternating macrocycles and nanoparticles.
This key comparison aims to assess the capabilities of the participants to determine the amount-of-substance fraction oxygen in nitrogen. The GAWG has classified this as a track B comparison, due to the unexpected 50 μmol/mol argon mole fraction content of the transfer standards, which effects the achievable performance of some measurement techniques such a GC-TCD. The separation of oxygen and argon is challenging, and not all systems in use are equally well designed for it. As this analytical challenge due to a substantial fraction of argon in the transfer standards became a reality, the Gas Analysis Working Group (GAWG) decided to qualify this key comparison as a regular key comparison and not as a core comparison, which may be used to support calibration and measurement capabilities (CMCs) for oxygen in nitrogen, or for oxygen in nitrogen mixtures containing argon only (see also the section on support to CMCs).
The impact of very high cycle fatigue (VHCF) load conditions on the microstructure of specimens consisting of nodular cast iron is analyzed by means of micro-computed tomography (µCT) utilizing both monochromatic synchrotron radiation and polychromatic X-ray tube radiation. Using 3D µCT, the microstructure in the region of the smallest cross-sections of shouldered round specimens is imaged in different stages of the VHCF loading. By digital image correlation (DIC) of these tomograms strain fields are analyzed three-dimensionally. Strain levels in the range of a few percent were detected. It is proven that a localization of strain allows to predict the site of the crack which precedes and induces the macroscopic failure of the specimens.
A method for the determination of safety properties for micro reactors and micro structured components is presented.
Micro structured reactors are not inherently safe but the range of safe operating conditions of micro reactors are
extended since the explosion region is reduced. The λ/3 rule was demonstrated to be applicable to micro scale
tubes for stoichiometric mixtures of ethane–oxygen and ethane–nitrous oxide. Furthermore first results from an investigation concerning detonation propagation through a micro reactor of non-ideal geometry are shown. Initial
pressure investigated is ranging from low pressure up to 100 kPa.
Well-defined and facetted bimetallic gold–palladium nanoalloys have been synthesized and anchored in spherical polyelectrolyte brushes (SPB) as composite particles (AuPd@SPB). These particles are better catalysts in aqueous phase than the pure metals. The atomistic arrangement of these nanoalloys has been analysed by extended X-ray absorption fine structure (EXAFS) spectroscopy at the Au–L3 and the Pd–K absorption edge. The samples with high amounts of gold appear as almost statistically mixed random alloys. Alloy compositions with less gold show slight enrichment of Pd at the surface of the particle. In addition, signals of non-metallic palladium appear at the Pd–K edge which indicate the presence of the Pd2+ species in addition to metallic palladium. The relation of these structural features to the catalytic activity is discussed.
The 3-dimensional spatial distribution of liquid water in different gas diffusion layer (GDL) materials was analyzed using synchrotron X-ray tomography. The capability of the method was demonstrated by virtually separating the GDL components in order to facilitate individual analysis of fiber material, liquid water and gas filled pore spaces. The influence of hydrophobic surface treatment on the water distribution in the GDL was illustrated by analyzing three GDL materials with different degrees of hydrophobicity. In the least hydrophobic sample, liquid water tends to form larger clusters which stretch out about several hundred µm inside the porous GDL. In contrast, only small water clusters were found in the strongly hydrophobic material with high Polytetrafluoroethylene (PTFE)-content as the liquid is partially pressed out of the GDL. Additionally, the influence of fiber orientation on the water distribution in the felt material was demonstrated.
The International Temperature Scale of 1990 (ITS-90) is based on thermodynamic equilibrium states of ideally pure substances. The largest contribution to the uncertainty budgets of most metallic fixed points is the influence of impurities on the fixed-point temperature. Therefore, a traceable chemical analysis of the remaining impurities with small uncertainty is the basis of further progress. Further requirements are better knowledge of the phase diagrams at very low impurity contents, impurity segregation, and the quantification and correction of thermal effects during a fixed-point realization. In this article, current and future activities at PTB and BAM in order to develop improved metallic fixed-point cells of the ITS-90 are reviewed.
The high-resolution synchrotron-based imaging stations at the BAMline (BESSY) and TopoTomo (ANKA)
(2008)
The BAMline at the BESSY light source in Berlin and the TopoTomo beamline at the ANKA synchrotron facility in Karlsruhe (both Germany) operate in the hard X-ray regime (above 6 keV) with similiar photon flux density. For typical imaging applications, a double multilayer monochromator or a filtered white beam is used. In order to optimise the field of view and the resolution of the available indirect pixel detectors, different optical systems have been installed, adapted, respectively, to a large field of view (macroscope) and to high spatial resolution (microscope). They can be combined with different camera systems, ranging from 16-bit dynamic range slow-scan CCDs to fast CMOS cameras. The spatial resolution can be brought substantially beyond the micrometer limit by using a Bragg magnifier. The moderate flux of both beamlines compared to other 3rd generation light sources is compensated by a dedicated scintillator concept. For selected applications, X-ray beam collimation has proven to be a reliable approach to increase the available photon flux density. Absorption contrast, phase contrast, holotomography and refraction-enhanced imaging are used depending on the application. Additionally, at the TopoTomo beamline digital white beam synchrotron topography is performed, using the digital X-ray pixel detectors installed.
A new approach was developed for quantitative calibration in GD-MS which can afford reliable and metrologically traceable results for many trace elements and was exemplified for pure copper and pure iron. It can be assumed that the technique can be further improved and applied to the analysis of other pure metals. Pressed copper and iron powder samples were used to calibrate the glow discharge mass spectrometry applied to the analysis of pure copper and iron. The new type of glow discharge mass spectrometerthe Element GD (Thermo Electron Corporation)was used with a Grimm-type discharge cell for flat samples. Two series of powder samples were prepared for each of the copper and iron matrixes. The powders were quantitatively doped with solutions of graduated and defined concentrations of 40 or 20 analytes, respectively. The mass fractions of the analytes in the dried and homogenized metal powder samples ranged from µg/kg levels up to 10 mg/kg levels. A special technique was developed to press the samples and to form mechanically stable pellets with low risk of contamination. Ion beam ratios of analyte ions to matrix ions were used as measurands. The calibration curves were determined and the linear correlation coefficients were calculated for different intervals of the curves. The linear correlation coefficients are very satisfactory for most of the calibration curves, which include the higher segments of mass fractions; however, they are less satisfactory for the lower segments of the calibration curves. Nevertheless, in many cases rather acceptable and rather promising values were achieved even for these lower segments, representing mass fractions of analytes at ultra-trace level. The comparison of the certified values of different reference materials with the measured values based on calibrations with the pressed powder samples led to deviations less than 30% for most of the considered examples.
Spatially resolved X-ray fluorescence analysis using synchrotron radiation (SR-XRF) at the wavelength shifter beamline, BAMline, at BESSY was used to investigate Renaissance silverpoint drawings as it is extremely sensitive, non-destructive and can be carried out in air using an excitation spot in the hundred micrometer range.
This paper deals with first results of the study of silverpoint drawings of Albrecht Dürer (14711528) belonging to the sketchbook that Albrecht Dürer used during a travel to the Netherlands in 1520/21. These results are compared to a PIXE study performed on drawings from the same sketchbook.
The minor element composition of the silverpoint used for the drawings in the sketchbook was (10.6 ± 3.5) wt.% of Cu and traces of Zn. Mercury was found in the marks but does not belong to the initial composition of the silverpoint as it is attributed to an alteration phenomenon. One drawing of the sketchbook represents an exception. It consists of silver marks containing an additional minor element, Zn, in the marks and was, therefore, created with another silverpoint, probably at a different time than the other drawings.
Synchrotron-induced X-ray fluorescence (Sy-XRF) analysis was used to study the chemical composition of precious Renaissance silverpoint drawings. Drawings by famous artists such as Albrecht Dürer (14711528) and Jan van Eyck (approximately 13951441) must be investigated non-destructively. Moreover, extremely sensitive synchrotron- or accelerator-based techniques are needed since only small quantities of silver are deposited on the paper. New criteria for attributing these works to a particular artist could be established based on the analysis of the chemical composition of the metal points used. We illustrate how analysis can give new art historical information by means of two case studies. Two particular drawings, one of Albrecht Dürer, showing a profile portrait of his closest friend, Willibald Pirckheimer (1503), and a second one attributed to Jan van Eyck, showing a Portrait of an elderly man, often named Niccolò Albergati, are the object of intense art historical controversy. Both drawings show inscriptions next to the figures. Analyses by Sy-XRF could reveal the same kind of silverpoint for the Pirckheimer portrait and its mysterious Greek inscription, contrary to the drawing by Van Eyck where at least three different metal points were applied. Two different types of silver marks were found in this portrait. Silver containing gold marks were detected in the inscriptions and over-subscriptions. This is the first evidence of the use of gold points for metal point drawings in the Middle Ages.
Rocks are commonly very heterogeneous materials. Randomly distributed micro-flaws inside the rock are believed to initiate tensile cracks from which shear fractures develop and coalescence through en echelon interactions leads to fracture. In this paper, we describe the results of applying high-resolution X-ray tomography to samples of greywacke and limestone experimentally deformed under unconfined axial shortening at various loads equivalent to different fractions of the sample strength. Mineral grains, pores, micro-cracks and other voids were imaged with a resolution of 10 µm. 3D image analysis enabled us to monitor the initial state of the samples and the changes in them due to compression. Crack morphology is characterized and compared to the micro-structure of the sample before and after deformation. In the greywacke, formation of a macro-crack ~10° oblique to the stress direction is observed. It initiated in fine intergranular material at the top tip of the sample and is composed of tensile fractures connected by wing cracks. None of the voids defined in the initial state fractured, and the crack is interpreted to have started either as a micro-crack which was smaller than the resolution of the tomography, or, as a completely new crack. In the limestone, cracks are observed to initiate in features that are too small to be imaged by the tomography, or also in newly created cracks.
X-ray topography is a well known imaging technique to characterise strain and extended defects in single crystals. Topographs are typically collected on X-ray films. On the one hand such photographic films show a limited dynamic range and the production of films will be discontinued step by step in the near future. On the other hand new imaging detectors improved for X-ray tomography become more and more attractive even for topography because of increasing resolution, dynamic range, speed and active area. In this paper we report about the upgrade of the TOPOTOMO beamline at the synchrotron light source ANKA, Research Centre Karlsruhe, with a high resolution digital camera for the topography use.
Mechanically interlocked molecules (MIMs) such as rotaxanes and catenanes are capable of mechanical motion on the nanoscale and are therefore promising prototypes for molecular machines in recent nanotechnology. However, most of the existing examples are isotropically distributed in solution, which prohibits concerted movement and with it the generation of macroscopic effects. Thus, arranging them in ordered arrays is of huge interest in recent research. We report the deposition of quite densely packed multilayers of tetralactam macrocycles on gold surfaces by metal-coordinated layer-by-layer self-assembly. Linear dichroism effects in angle-resolved NEXAFS spectra indicate a preferential orientation of the macrocycles. The sequence of the metal ions can be programmed by the use of different transition metal ions at each deposition step. Additionally, reversible on-surface pseudorotaxane formation was successfully realized by repeated uptake and release of axle molecules inside the macrocycles cavities.
Water transport in an operating PEM fuel cell was investigated with synchrotron X-ray radiography with a spatial resolution of 3 µm and a temporal resolution of 5 s. This method allows for the detection of water accumulations with less than 10 µm diameter. We demonstrate that synchrotron X-ray imaging can dramatically expand the possibilities of imaging with high spatial and time resolution, especially as a complement to neutron radiography. Water transport processes from the first appearance of small water accumulations in the gas diffusion layer to their transport into the channel system were analysed in situ. Correlations between local effects such as water formation and operating conditions of the whole system, e.g. power variations, were found. A recently described eruptive water transport mechanism is analysed in detail.
The paper will give an overview of new methodology for evaluating the
reliability of NDE systems accurately, reliably and efficiently in accordance with the
specific requirements of industrial application. After a review of the substantive
issues from the previous workshops, the go forward guidance from these
interactions is considered.
At the beginning of the reliability analysis, the actual safety demands have to
be defined in order to fit the investigation to the level of risk when the component
would fail. Next, all the essential influencing parameters need to be documented and
transferred to an appropriate design of experiments (DOE) to determine the
reliability in terms of a qualitative assessment for lower risk or in terms of a
quantitative probability of detection (POD) or ROC (Receiver Operating
Characteristics) curves for higher safety demands. A new paradigm is offered to
consider the POD or reliability of the system as a function of the configuration of
input variables and use it for optimisation rather than for a final judgement. An
advantage for the end user is also to sample all single PODs to an integral 'Volume
POD' of a part.
Among the influencing parameters, the human factor is the most important one.
A systematic psychological approach shall help to find out where the bottlenecks are
but most importantly to provide best possible working conditions for the human
inspectors.
A new high-resolution detector setup for neutron imaging has been developed based on infinity-corrected optics with high light collection, combined with customized mounting hardware. The system can easily be installed, handled and fitted to any existing facility, avoiding the necessity of complex optical systems or further improved electronics (CCD). This is the first time optical magnification higher than 1:1 has been used with scintillator-based neutron detectors, as well as the first implementation of infinity corrected optics for neutron imaging, achieving the smallest yet reported effective pixel size of 3.375 µm. A novel transparent crystal scintillator (GGG crystal) has been implemented with neutrons for the first time to overcome limitations of traditional powder scintillators (Li6/ZnS, Gadox). The standardized procedure for resolution measurements with the Modulation Transfer Function (MTF) is summarized to facilitate comparison between instruments and facilities. Using this new detector setup, a resolution of 14.8 µm with a field of view of 6 mm × 6 mm has been achieved while maintaining reasonable count times. These advances open a wide range of new possible research applications and allow the potential for additional future developments.
Most additive manufacturing (AM) techniques have in common that material is spread out as thin layers of a dried powder/granulate by a roller or a shaker system. These layers are mostly characterized by a low packing rate. On the other hand, appreciable densities can be reached by the use of ceramic slurries. In this context, the layer-wise slurry deposition (LSD) has been developed. Specific features of the LSD process are reflected on the basis of already existing additive manufacturing technologies. The microstructure of laser-sintered bodies will be discussed, and strategies for an improved microstructure during sintering will be introduced.
In order to investigate molecular recognition on surfaces, an azide-functionalized monolayer was deposited on gold. The monolayer was characterized by X-ray photoelectron spectroscopy (XPS) and angle-resolved near-edge X-ray absorption fine structure (NEXAFS) experiments and the decomposition of the azide upon irradiation with X-ray beams was investigated. Subsequently, various alkyne-functionalized host and guest molecules were attached to the azide by 1,3-dipolar cycloaddition. These modified surfaces and their host–guest chemistry were analysed by XPS and angle-resolved NEXAFS. The reversibility of guest binding was shown for one example as a proof of principle.
Solution-doped metal powder pellets as well as aspirated liquids were used as calibration samples to analyze pure copper and zinc certified reference materials (CRMs) by femtosecond laser ablation ICP-MS. It was demonstrated that calibration by copper pellets resulted in relative deviations up to 20%, whereas fs-LA-ICP-MS among copper-based CRMs led to inaccuracies in the same range unless nominal mass fractions were chosen to be <3 mg/kg. Calibration by zinc pellets generally provided better accuracy. Depending on the analyte considered, deviations below 10% were obtained even for mass fractions close to the limit of quantification. Our data, therefore, indicate solution-doped metal powder pellets to be suitable as calibration samples for fs-LA-ICP-MS of metals. Furthermore, the utilization of liquid standards for calibration was found to result in stronger deviations of up to 50% for both copper and zinc samples which, in addition, turned out to be dependent on the plasma conditions.
Determining the influence of impurities on the fixed-point emperatures
of the ITS-90 requires the completion of several tasks. In this paper, the Progress made at Physikalisch-Technische Bundesanstalt (PTB) and BAMFederal Institute for Materials Research and Testing is presented and remaining questions are discussed.
The projected characterization procedure at PTB, which is based on the established SIE method (sum of the individual estimates), using a new indium fixed-point cell is described as an example. This procedure includes an SI-traceable chemical Analysis of the material in the fixed-point cell with sufficiently low uncertainties, the individual experimental determination of the influence of the quantified impurities on the fixed-point temperature, and the establishment of direct links to the phase-transition temperatures of the national standard and of an assumed material of ideal purity.
A characteristic difference to the common practice is the chemical analysis of the fixed-point metal being done after determining the cells freezing temperature. This allows for the detection and consideration of contamination and purification effects due to the filling process, or due to the contact with the carbon crucible and other parts of the fixed-point cell. A chemical analysis of an indium fixed-point was carried out by BAM with relative measurement uncertainties below 30 % which have not been previously achieved. The results provide evidence for the precipitation of some impurities,
which is apparently inconsistent with the corresponding binary phase diagrams, but was explained in a recent publication. Implications for the use of the SIE method shall be described briefly at the end.