Filtern
Dokumenttyp
Referierte Publikation
- ja (3) (entfernen)
Schlagworte
- Monitoring (2)
- Corrosion (1)
- Design for durability (1)
- Korrosion (1)
- Macrocell corrosion model (1)
- Reinforcement corrosion (1)
Organisationseinheit der BAM
Paper des Monats
- ja (1)
The paper presents the damage model of German Research Unit 537 which was used as a working hypothesis for the development of a user-friendly design model. Excerpts from the laboratory experiments and numerical calculations processed in project A of the research unit are presented here. The excerpts include the quantification of self-corrosion, geometrical effects in the macrocell corrosion, development of corroding steel surface and pit depth as well as the quantification of the resistivity of the concrete and the corrosion of steel in cracked concrete.
Korrosionsmonitoring von Stahl- oder Spannbetonbauwerken hat in den vergangenen Jahren als Ergänzung zur herkömmlichen Bauwerksuntersuchung deutlich an Relevanz gewonnen. Einsatzgebiete sind z. B. Bauteile, die nach Fertigstellung nicht mehr zugänglich sind oder an denen aufgrund vorhandener Beschichtungen keine Potentialfeldmessungen durchgeführt werden können. Weiterhin kann Korrosionsmonitoring auch für die Überwachung des Korrosionsfortschritts an korrodierenden Systemen z. B. zum Nachweis des Instandsetzungserfolgs bei Anwendung des Prinzips W-Cl gemäß Instandsetzungsrichtlinie des DAfStb oder zum Funktionsnachweis bei KKS-Installationen nach DIN EN ISO 12696 eingesetzt werden. Trotz zunehmender Bedeutung Existieren für das Korrosionsmonitoring bis dato keine Richtlinien oder Handlungsempfehlungen. Diese Lücke soll das Merkblatt B12 „Korrosionsmonitoring von Stahl- und Spannbetonbauwerken“ der Deutschen Gesellschaft für
zerstörungsfreie Prüfung DGZfP füllen, das im Frühjahr 2018
veröffentlicht wurde. In diesem Beitrag werden das Merkblatt B12 vorgestellt, die grundlegenden Messprinzipien erläutert und anhand von Anwendungsbeispielen das Potenzial von Korrosionsmonitoring bei Neubau- und Bestandsobjekten illustriert.
Corrosion monitoring of reinforced concrete structures:The DGZfP specification B12 Collaboration
(2023)
Corrosion monitoring of reinforced or prestressed concrete structures has becomeincreasingly important in recent years. Areas of application include componentsthat are no longer accessible after completion or where potential fieldmeasurements cannot be carried out due to existing coatings. Corrosion monitoringcan also be used to monitor the progress of corrosion in corroding systems, e.g. to prove the success of repair measures according to repair principle 8 in accordancewith EN 1504‐9 or repair method 8.3 in accordance with the DIBt repair guideline.It also could be used to prove the functionality of cathodic corrosion protectionsystems in accordance with ISO 12696. Despite the increasing importance ofcorrosion monitoring, no guidelines orrecommendations existed until 2018. Thisgap was closed by the English version of specification B12,“Corrosion Monitoringof Reinforced and Prestressed Concrete Structures,”of the German Society for Non‐Destructive Testing, which was published in 2021. This article introducesspecification B12 by explaining the basicmeasurement principles and illustratingthe potential of corrosion monitoring in new and existing buildings.