Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (21)
- Beitrag zu einem Tagungsband (7)
- Beitrag zu einem Sammelband (6)
- Forschungsbericht (5)
- Sonstiges (2)
- Handbuch (1)
Schlagworte
- Korrosion (8)
- Corrosion (7)
- Spannstahl (5)
- Stahlbeton (5)
- Atmospheric corrosion (4)
- Stainless steel (4)
- Betonstahl (3)
- Chlorinduzierte Korrosion (3)
- Kathodischer Korrosionsschutz (3)
- Nichtrostende Stähle (3)
- Oberflächenschutzsystem (3)
- Spannbeton (3)
- Thermische Spritzverzinkung (3)
- Verzinkte Einbauteile (3)
- Wasserstoffinduzierte Spannungsrisskorrosion (3)
- Chromate (2)
- Concrete (2)
- Corrosion protection (2)
- Einflussgrößen (2)
- Electrochemical tests (2)
- Grease (2)
- Hydrogen evolution (2)
- Hydrogen-induced stress corrosion cracking (2)
- Korrosionsschutz (2)
- Potentialfeldmessung (2)
- Prestressed systems (2)
- Prestressing steel (2)
- Reinforcement (2)
- Reinforcing steel (2)
- Verzinkt (2)
- Wax (2)
- Werkstoffauswahl (2)
- Aluminium (1)
- Atmosphäre (1)
- Atmosphärische Korrosion (1)
- Auslagerungsversuche (1)
- Bauwesen (1)
- Bewehrung (1)
- Bewehrungsstahlkorrosion (1)
- Boden (1)
- Bodenkontakt (1)
- Cathodic protection (1)
- Cement (1)
- Chlorid-induced corrosion (1)
- Chloride (1)
- Chloridinduzierte Korrosion (1)
- Civil engineering (1)
- Concrete parameters (1)
- Corrosion resistance (1)
- Corrosion testing (1)
- DIN 1045 (1)
- Dauerhaftigkeit (1)
- Duplex stainless steels (1)
- Duplex-Stähle (1)
- EPR test (1)
- Electrochemical measurements (1)
- Elektrochemische Versuche (1)
- Exposition (1)
- Exposure tests (1)
- Failure (1)
- Fehlerquellen (1)
- Feuerverzinkt (1)
- Free weathering (1)
- Gabionen (1)
- Galvanic corrosion (1)
- Galvanized construction elements (1)
- Galvanized elements (1)
- Galvanized rebar (1)
- Galvanized steel (1)
- Galvanostatische Pulsmessungen (1)
- Grinding (1)
- Indoor swimming pools (1)
- Intercrystalline corrosion (1)
- Interkristalline Korrosion (1)
- Kathodische Polarisation (1)
- KorroPad (1)
- Korrosionsschutzmittel (1)
- Langzeitverhalten (1)
- Lochkorrosionspotential (1)
- Marine atmosphere (1)
- Maritime Atmosphäre (1)
- Maritime atmosphere (1)
- Messraster (1)
- Monitoring (1)
- Nachweisgrenzen (1)
- Nichtrostender Stahl (1)
- Passive layer (1)
- Pitting corrosion (1)
- Polarization (1)
- Potential mapping (1)
- Potentialfeldmessungen (1)
- Potentialmessung (1)
- Praktische Bedeutung (1)
- Prestressed concrete (1)
- Prüfprotokoll (1)
- Pull-out tests (1)
- Rebar (1)
- Salinization (1)
- Schutzwirkung (1)
- Schäden (1)
- Self-corrosion (1)
- Spaltkorrosionspotential (1)
- Sprayed zinc layer (1)
- Stainless steels (1)
- Steel reinforcement (1)
- Surface finish (1)
- Surface protection system (1)
- Verbund (1)
- Verfahrensbeschreibung (1)
- Versalzung (1)
- Wasseraufnahme (1)
- X-ray tomography (1)
- Zerstörungsfreie Prüfung (1)
- Zinc (1)
- Zink (1)
- Zink-Aluminium-Überzug (1)
Organisationseinheit der BAM
Electrochemical potential mapping according to guideline B3 of DGZfP (German Society for Nondestructive Testing) is a recognized technique for the localization of corroding reinforcing steels. In reinforced concrete structures the measured potentials are not necessarily directly linked to the corrosion likelihood of the reinforcing steel. The measured values may be significantly affected, different from, e.g., stress measurement, by different influences on the potential formation at the phase boundary metal/concrete itself as well as the acquisition procedure. Due to the complexity of influencing factors there is a risk that the results are misinterpreted. Therefore, in a training concept firstly the theoretical basics of the test method should be imparted. Then, frequently occurring practical situations of various influencing factors will be made accessible to the participants by a model object specially designed for this purpose. The aim is to impart profound knowledge concerning the characteristics of potential mapping for detecting corrosion of reinforcing steel in order to apply this technique in practice as reliable and economical test method.
The salinization and contamination of metal surfaces by chloride-containing aerosols is of great importance with regard to corrosion phenomena of damaged coated metal surfaces and stainless steels in the maritime sector and in offshore applications. Detailed questions have to be answered to clarify whether and to what extent salinization of the surface has an influence on the adhesion and durability of coatings in repairing applications and on pitting occurrence on stainless steels under atmospheric conditions. The questions arise which degree of salinization is reached after which period of time and how a defined and reproducible salinization can be simulated in the laboratory for further systematic investigations. The article is dedicated to these questions. Results of a field trial on the Island of Heligoland are presented and a simple procedure for a defined loading of metal surfaces with chlorides at a laboratory scale using a design of experiments (DoE) approach is introduced.