The curing conditions play an important role in the quality assurance of composite products.
Especially as composite materials are widely used in high tech areas so that they are required to fulfil high quality Standards. Some problems which occur during curing, for instance undercuring, can hardly be detected using Standard NDT investigations, mainly because they are manifested only at high temperatures, particularly close to glass-rubber-transition. On-line eure monitoring has the outstanding advantage that it can monitor the material parameters even at the highest temperatures possible.
In recent years eure monitoring with ultrasonic methods has become more populär. In comparison to dielectric methods mechanical parameters are measured directly. The quantities to be measured are the velocity and the attenuation of the sound wave. On this basis the storage and loss modulus can be calculated. Depending on the form of excitation with longitudinal or transversal waves these moduli are referred to as long wave or shear modulus.
Well developed Computer based technology and sensor materials are available in the non-destructive testing (NDT) market. The measuring equipment employed a commercial NDT System, which worked computer-aided. With a special Software the demands of automatic Operation under industrial conditions was accomplished. This measurement equipment was tested on composites. Its structure, performance and some practical results will be presented in the following paper.
Making Cure Visible
(2005)
Analysis of the dielectric and electromechanical properties of the cellular polypropylene ferroelectret films (EMFIT) evidences their high potential for the application in the air-coupled ultrasonic transducers. Simple prototype transducers, based on the EMFIT films, were developed and their high sensitivity was proved in the air-coupled ultrasonic experiment. Amplitude and delay time scanned images of the polyethylene step wedge with holes, obtained in both pulse-echo and transmission modes, demonstrate that non-contact ultrasonic imaging with EMFIT transducers is possible.
Die Ultraschallmikroskopie von kleinen Bauteilen mit fokussierenden Prüfköpfen
ist seit Jahren gängige Praxis. Leider Ist sie für den Einsatz in der On-Line-
Qualitätskontrolle zu zeitaufwändig. Deshalb wurde an der Bundesanstalt für
Materialforschung und -prüfung (BAM) auf der Basis von Polyvinyliden-Fluorid
(PVDF) wurde eine fokussierende Wandlerzeile entwickelt Sie ist Teil eines Prüfgerätes,
das durch die Verbindung von mechanischer und elektronischer Steuerung
des Ultraschallfeldes hohe Abtastgeschwindigkeiten erreicht. Dadurch, können
die Prüfzeiten so stark reduziert werden, dass eine On-line-Nutzung möglich
wird.
Das Ultraschallfeld der Wandlerzeile wurde dreidimensional ausgemessen und
das Ergebnis mit einem numerischen Modell /1/ verglichen. Die Übereinstimmung
zwischen berechnetem und gemessenem Schallfeld war sehr gut. Eine
Optimierung der elektronischen Ansteuerung führte darüberhinaus zu einer
erheblichen Reduzierung der störenden Nebenmaxima. Die Mittenfrequenz der
Prüfimpulse liegt über 15 MHz und der Fokus des Prüfkopfes beträgt weniger als
0,5 mm im Durchmesser.
Mit dieser Wandlerzeile und der entsprechenden elektronischen Steuerung
wurde eine Aluminium-Schweißnaht untersucht, die vorher mit einem konventionellen
fokussierenden Prüfkopf abgetastet worden war. Beide Prüfergebnisse
zeigen die gleiche Strukturauflösung, so dass der Zeitgewinn uneingeschränkt
als Vorteil für die Wandlerzeile zu Buche schlägt.