Filtern
Dokumenttyp
Schlagworte
- Ferroelectrets (3)
- Non-contact transducers (3)
- Air-coupled ultrasonics (2)
- Cellular polypropylene (2)
- Electromechanical properties (2)
- Electrostriction (2)
- Ultrasonic transducer (2)
- Air borne transducer (1)
- Air coupled ultrasonics (1)
- Air coupled ultrasound (1)
- Airborne ultrasonics (1)
- Electret film (1)
- Electromechanical effects (1)
- Ferroelectret (1)
- Ferroelectret film (1)
- Ferroelectric devices (1)
- Ferroelektret (1)
- Luftschall-ZfP (1)
- Luftultraschall (1)
- Non-contact ultrasound (1)
- Non-destructive testing (1)
- Nonlinearity (1)
- Piezoelectric effect (1)
- Piezoelectric film (1)
- Piezoelectric transducers (1)
- Piezoelectricity (1)
- Prüfkopf (1)
- Pulse compression (1)
- Pulsed THz radiation system (1)
- THz imaging (1)
- Time domain spectroscopy (1)
- Transducer (1)
- Ultraschall-Wandler (1)
- Ultrasonic transducers (1)
- Ultrasonic transmission (1)
- Zerstörungsfreie Prüfung (1)
Polypropylene based ferroelectret films exhibit a strong electromechanical activity and provide a promising solution for the air coupled ultrasonic (ACUS) transducers. Ultrasonic transmission between two air coupled ferroelectret transducers in dependence on the amplitude and polarity of the high voltage exciting pulse revealed a strongly non-linear electromechanical response of the ferroelectret transmitter which provides an increase in the transmitter efficiency. The authors present a simple model describing both promotion and competition of the piezoelectric and electrostriction contributions, as well as increase in the transducer constant under high voltage excitation. Enlargement of the inverse transducer constant of the polypropylene ferroelectret film by a factor of 4 was demonstrated. The non-linear properties of the polypropylene ferroelectrets result in a strong increase in their ACUS figure of merit under the high voltage excitation, which exceeds the results of their technological optimisation. Consequently, enhancement of the ACUS system transmission by 12 dB and signal to noise ratio by 32 dB was achieved.
Für die luftgekoppelte Ultraschall-Prüfung wird der Prototyp eines neuartigen Prüfkopfes vorgestellt. Statt eines piezokeramischen Ultraschall-Wandlers mit einer λ/4-Anpassschicht wird eine Ferroelektret-Folie aus schaumförmigem Polypropylen eingesetzt. Durch die außerordentlich geringe akustische Impedanz der Folie reduzieren sich die Reflexionsverluste an den Grenzschichten zur Luft so stark, dass bei diesem Prüfkopf auf eine λ/4-Anpassschicht verzichtet werden kann. Außerdem ist die Folie hochspannungsfest. Sie konnte mit Spannungen von mehr als 3500 V angesteuert werden und erlaubte eine Vorspannung am Ultraschall-Wandler des Empfangsprüfkopfes von 2000 V. Mithilfe der hohen Anregungsspannung stieg die Amplitude des akustischen Prüfimpulses auf das 11,2-Fache. Die Empfindlichkeit des Empfängers erhöhte sich durch die Vorspannung weiter um den Faktor 4,3. Insgesamt steigt die Amplitude am Empfänger also auf das 48-Fache, bei gleichbleibendem Rauschpegel. Ein abschließender Vergleich mit kommerziellen Luftultraschall-Prüfköpfen belegt die Überlegenheit der Folien-Prüfköpfe. Damit rückt der Einsatz einer vollwertigen Impuls-Echo-Technik auch bei der luftgekoppelten Ultraschallprüfung deutlich näher.
Analysis of the dielectric and electromechanical properties of the cellular polypropylene ferroelectret films (EMFIT) evidences their high potential for the application in the air-coupled ultrasonic transducers. Simple prototype transducers, based on the EMFIT films, were developed and their high sensitivity was proved in the air-coupled ultrasonic experiment. Amplitude and delay time scanned images of the polyethylene step wedge with holes, obtained in both pulse-echo and transmission modes, demonstrate that non-contact ultrasonic imaging with EMFIT transducers is possible.
Dielectric and electromechanical properties of the cellular polypropylene ferroelectret films (EMFIT), combining strong piezoelectric response with a low density and softness, evidence their high potential for the air-coupled ultrasonic applications. The disadvantage of the low coupling factor is compensated by the extremely low acoustic impedance, which provides excellent matching to air and promises efficient sound transmission through the airtransducer interface. The influence of the electrodes on the electromechanical properties was investigated. Electron beam evaporation technology was adapted to the EMFIT films, and films with both-sided Au and Al electrodes were prepared without reducing or suppressing of the electromechanical properties. Finally, prototype transducers based on the EMFIT films were developed. In spite of the simple construction and absence of matching layers, high sensitivity of the EMFIT transducers was proved in the air-coupled ultrasonic experiment. Amplitude and delay time scanned images of the polyethylene step wedge with holes, obtained in both pulse-echo and transmission modes, demonstrate that non-contact ultrasonic imaging and testing with EMFIT transducers is possible.
The ultrasonic transmission between two air-coupled polypropylene (PP) ferroelectret (FE) transducers in dependence on the amplitude of the high-voltage exciting pulse revealed a strongly nonlinear electromechanical response of the FE transmitter. This phenomenon is described by a linear increase of the inverse electromechanical transducer constant t33(1) of the PP FE film with an increase of the exciting electrical pulse amplitude. Enlargement of t33(1) by a factor of 4 was achieved by application of 3500 V exciting pulses. The electrostriction contribution to t33(1) can be attributed to the electrostatic force between electrodes and the Maxwell stress effect. The nonlinear electromechanical properties of the PP FE result in a strong increase of its air-coupled ultrasonic (ACUS) figure of merit (FOM) under the high-voltage excitation, which exceeds results of the PP FE technological optimization. The FOM increase can be related to the increase of PP FE coupling factor and/or to the decrease of its acoustic impedance. A significant enhancement of the ACUS system transmission (12 dB) and signal-to-noise ratio (32 dB) was demonstrated by the increase of excitation voltage up to 3500 V. The nonlinear electromechanical properties of the PP FEs seem to be very important for their future applications.
Electromechanical response of polypropylene ferroelectret transducers under application of high-voltage pulses was measured by laser Doppler vibrometry and compared with results of ultrasonic through-air transmission between two ferroelectret transducers. The electromechanical response was completely explained by piezoelectric and electrostrictive effects. The electrostrictive effect dominates at high voltages and provides significant enlargement of the transducer constant, up to factor of 2.5. The induced strain of 1.7% was achieved at – 2000 V. The nonlinear ultrasonic transmission was shown to be well described by the piezoelectric and electrostrictive response of transmitter, except in the range of high negative exciting voltages where some limitation of the transmitted signal was observed. This limitation seems not to be a fundamental one and does not abolish the advantages of high-voltage excitation of polypropylene ferroelectret transducers.
An Methoden zur luftgekoppelten Ultraschallprüfung wird seit einigen Jahren mit großer Intensität gearbeitet. Probleme bei der praktischen Realisierung entstehen vor allem durch die großen Unterschiede in der akustischen Impedanz von Wandlermaterial und Luft. Sie führen zu erheblichen Signaldämpfungen. Durch die Verwendung von Kunststoff-Folien z.B. aus porösem Polypropylen kann dieser Unterschied stark reduziert werden.
Im Beitrag werden die akustischen Eigenschaften dieser Folien untersucht und im Hinblick auf ihre Eignung für die Luftultraschall-Technik analysiert.