Ferroelectrets are promising materials for air-coupled ultrasonic transducers. A transducer made of polarized cellular polypropylene, including its electronic interface, was developed and compared with conventional air-coupled probes. Test pieces of fiber-reinforced polymer containing impact flaws and flat-bottom holes were inspected in transmission. The ferroelectret transducers achieved a considerably higher signal-to-noise ratio. The impacts were clearly visible with all transducers, but less noisy with ferroelectret transducers. The flat-bottom holes were better detectable than with a conventional probe with about the same focus size.
Making Cure Visible
(2005)
Charakterisierung der Wandler für Luftultraschallprüfung aus zellulärem Polypropylen-Ferroelektret
(2011)
In den letzten Jahren stieg die Anfrage für zerstörungsfreie Prüfung (ZIP) mit Luftultraschall deutlich. Die klassische ZfP mit Ultraschall nutzt Flüssigkeiten als Koppelmittel zwischen dem Wandler und dem Prüfkörper. Für die Prüfung von Gegenständen mit empfindlicher Oberfläche, die das Koppelmittel beschädigen oder verunreinigen kann, ist deswegen Luftultraschall besser geeignet. Eine mögliche Anwendung ist beispielsweise der Nachweis von Delaminationen in glas- und kohlefaserverstärkten Verbundwerkstoffen sowie Sandwichbauteilen, die in der Luftfahrt- und der Automobilindustrie eingesetzt werden.