Filtern
Dokumenttyp
Sprache
- Englisch (5)
Referierte Publikation
- ja (5)
Schlagworte
- Gas chromatography (5) (entfernen)
The 2-year international joint project HYCREF (Contract-No. G6RD-CT-2002-00854), funded by the European Commission in the 5th Framework programme, aimed to develop methods to prepare homogenous and stable water-, soil- and waste reference materials contaminated with mineral oil hydrocarbons and to test certify the mineral oil content by gas chromatographic methods. As mineral oil products are important sources for environmental contaminations, appropriate reference materials certified by using the new gas chromatographic methods (soil: ISO/FDIS 16703, waste: prEN 14039 and KW/04, water: ISO 9377-2) are highly needed. Additional to the HYCREF-results presented in part Imineral contaminated soilsthis second paper gives an overview of the feasibility study for the preparation and test certification of three waste reference materials (offshore marine sediment, building material and industrial waste). The following specifications, which had been defined in the project work plan, were reached successfully: uncertainty of the mineral oil content resulting from the certification exercise ≤ 5% and a between-bottle inhomogeneity of ≤ 3%. All three materials have been evaluated for long- and short term stability. They contain different levels and types of mineral oil and cover the full application range of ISO/FDIS 16703 and prEN 14039 (10010,000 mg/kg). The expanded uncertainties U cert of the three materials are about 6%. In this way, they are comparable to ERM®-CC015a (U cert=7.1%, mineral oil in a river sediment) and are suited to close the present gap of commercially available CRM for mineral oil determination in waste.
The performance of twelve laboratories with previously established proficiency in the determination of the mineral oil content in a fresh water sediment is described. The summation parameter total petrol hydrocarbon (TPH) is defined according to ISO 16703:2004 with regard to the sample preparation to be applied, the flame ionisation detection (FID) and the boiling range of C10C40 to be integrated. Comprehensive tests of homogeneity and stability have been carried out on the candidate material using appropriate models. The outcome of the study served as the basis for the certification of the candidate reference material as ERM-CC015a. The certified mass fraction is 1,820±130mgkg-1 and traceability was established by using an appropriate calibration standard certified for the mass fraction of C10C40. The interlaboratory scatter of measurement results in this exercise can largely be explained by the variability of the individual calibrations based on this common calibration standard.
Liquid chromatography coupled with tandem mass spectrometric detection has gained more importance for mycotoxin determination in recent years. In addition to instrumental improvements, the development of LC-MS-MS has also been a consequence of the availability of stable isotope internal standards, e.g., 13C-labelled mycotoxins. Thus, the LC-ESI-MS-MS method using a 13C15-deoxynivalenol internal standard as a state-of-the-art technique was selected as a reference procedure for an in-house method comparison study of the determination of deoxynivalenol (DON) in wheat materials. Alternative methods include LC-diode array detection, which is a frequently used routine procedure for DON-analysis, and gas chromatography after trimethylsilylation. For GC application, an electron capture detector and a negative chemical ionisation mass spectrometry detector were used, which have both been well described in the literature. The method comparison was conducted using t test statistics. Additionally, this study also calculates important method performance characteristics, including accuracy, linearity, limit of detection, limit of quantification, recovery, and variation coefficient. Furthermore, this is the first report of a GC-MS method for the determination of DON using a fully carbon-labelled 13C15-DON as an IS. The GC-MS using 13C15-DON as an IS has produced comparable results to the 13C-IS-LC-MS-MS reference method with a similar sensitivity. ECD detection was slightly less sensitive, but is also suited for DON analysis in wheat. Due to the high LOQ, the LC-DAD method seems highly applicable to the measurement of highly contaminated samples.
Process waters obtained from hydrothermal carbonization (HTC) of wheat straw, a biogas digestate derived thereof, and four woody biomass feedstocks were quantified regarding the total organic carbon (TOC) and selected organic compounds. HTC runs revealed that TOC loads were largely unaffected by process severity or type of feedstock whereas the C2–C6 fatty acids, determined by GC, displayed clear effects of temperature and feedstock. HPLC demonstrated simultaneously the initial increase and subsequent consumption of cellulose-derived furfural and 5-hydroxymethylfurfural as well as the increase of the lignin-derived 2-methoxyphenol. 2-Methylbenzofuran, an example for a substance potentially harmful to aquatic biota, was observed in high concentration in the HTC liquor from wheat straw-based feedstocks.
The design and operation of an observational study on the profiles of volatile organic compounds (VOC) in the breath of 37 lung cancer patients and 23 healthy controls of similar age is outlined. The necessity to quantify each VOC considered as potential disease marker on basis of individual calibration is elaborated and the quality control measures required to maintain reproducibility in breath sampling and subsequent instrumental trace VOC analysis using SPME-GC-MS over a study period of 14 months are described. 24 VOC were quantified on basis of their previously suggested potential as cancer markers. The breath concentration levels of aromatic compounds was expectedly increased in smokers while lung cancer patients displayed significantly increased levels of oxygenated VOC such as aldehydes, 2-butanone and 1-butanol. Though sets of selected oxygenated VOC displayed sensitivities and specificities between 80 and 90% using linear discriminant analysis with leave-one-out cross validation the effective selectivity of the breath VOC approach with regard to cancer detection is clearly limited. Results were discussed against the background of the literature on volatile cancer marker investigations and the prospects to link increased VOC levels in patients’ breath with approaches to employ sniffer dogs. Experiences from this study and the literature suggest that the current state of breath VOC based discrimination between cancer patients and healthy controls is hardly improvable. Observational studies tend to observe significant differences mostly in levels of certain oxygenated VOC but without resolution required for practical application. Any step towards practicable exploitation of VOC profile differences for illness detection would have to solve current restrictions set by the low and variable VOC concentrations. Further challenges are the technical complexity of studies involving breath sampling and possibly the limited capability of current analytical procedures to detect instable marker candidates.