Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (98)
- Vortrag (23)
- Beitrag zu einem Tagungsband (17)
- Posterpräsentation (14)
- Forschungsbericht (8)
- Beitrag zu einem Sammelband (2)
Schlagworte
- Gas chromatography (5)
- HPLC-MS/MS (5)
- Analytik (4)
- Brominated flame retardant (4)
- Crystal structure (4)
- ERM (4)
- Extraction (4)
- Ochratoxin A (4)
- AHTN (3)
- Acrylamid (3)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (23)
Referenzmaterialien
(1998)
Tenuazonic acid (TA) is a major water soluble Alternaria mycotoxin. In the present work, a method for the quantification of TA in beer by liquid chromatography-ion-trap multistage mass spectrometry after derivatization with 2,4-dinitrophenylhydrazine is described. The method is based on a rapid workup procedure and features a LOD of 2 µg/kg without preconcentration using 400 mg of sample. Validation was performed for a working range of 8-500 µg/kg.
A total of 43 beers of different brewing styles (pilsener, wheat beer, bock beer, dark beer and alcohol free beer) was analysed. TA was detected in 37 samples, 16 samples were above the LOQ. An average content of 11 µg/kg was found, the highest incidence being 175 ± 13 µg/kg. To our knowledge, this is the first report on the occurrence of TA in beer and beverages in general.
A procedure for the quantification of the PCB marker congeners 28, 52, 101, 138, 153, 180 in plastic waste form the recycling of cables in the range of content between 0.1 mg kg-1 and 20 mg kg-1 was validated. Representative reference materials for laboratory analyses were produced using granulates from different recycling processes. The method development included aspects of grinding, sieving, homogenising as well as the comparison of extraction methods and chromatographic conditions. The validated procedure foresees grinding of the technical sample to an upper particle size limit of 0.50 mm followed by extraction with an unpolar solvent such as n-hexane and gas chromatographic determination. LOD and LOQ for individual congeners ranged between 0.01 mg kg-1 and 0.08 mg kg-1. Electron capture detection (ECD) and mass selective detection (MS) were equivalent if chromatographic conditions were appropriately selected. The application of MS was advantageous in presence of significant amounts of interfering components which have been found in some cables.
Three reference materials containing the marker congeners in the range of 0.1 mg kg-15 mg kg-1 were submitted to a final validation intercomparison with 23 selected field laboratories using the developed method. Relative reproducibility standard deviations varied between 15% and 33%.
Aim: The objective of the study was to provide conclusive evidence for the effect of particle size reduction as by milling on the extractable content of ethyl glucuronide (EtG) of hair samples. Methods: A number of real case hair samples and two pooled hair materials with EtG contents in the range of 1030 pg/mg were systematically compared with regard to the extraction yield of EtG after cutting to 23 mm length and pulverization with a ball mill. After the respective treatment the samples were submitted to aqueous extraction followed by quantification of EtG using HPLC-MS/MS. Results: It was unequivocally demonstrated that milling of hair samples prior to aqueous extraction significantly increases the extractable EtG content compared with cut hair. The effect ranged between 137 and 230% and was seen to occur regardless of the extent of pulverization. Cooling of samples was not necessary to prevent partial degradation of EtG during the grinding procedure. Conclusion: The options currently employed at choice in analytical practice (cutting or milling) were seen to significantly affect the extractable amount of EtG in hair. This is suspected to influence the degree of equivalence of quantification results obtained in different laboratories as well as their respective classification of a test subject's drinking behaviour on the basis of currently recommended cut-off values.