- nein (23)
The degradation and epimerization of ergot alkaloids (EAs) in rye flour were investigated after baking cookies and subsequently subjecting them to an in vitro digestion model. Different steps of digestion were analyzed using salivary, gastric, and duodenal juices. The degradation and bidirectional conversion of the toxicologically relevant (R)-epimers and the biologically inactive (S)-epimers for seven pairs of EAs were determined by a HPLC method coupled with fluorescence detection. Baking cookies resulted in degradation of EAs (2–30 %) and a shift in the epimeric ratio toward the (S)-epimer for all EAs. The applied digestion model led to a selective toxification of ergotamine and ergosine, two ergotamine-type EAs. The initial percentage of the toxic (R)-epimer in relation to the total toxin content was considerably increased after digestion of cookies. Ergotamine and ergosine increased from 32 to 51 % and 35 to 55 %, respectively. In contrast, EAs of the ergotoxine type (ergocornine, α- and β-ergocryptine, and ergocristine) showed an epimeric shift toward their biologically inactive (S)-epimers. Further experiments indicated that the selective epimerization of ergotamine EAs occurs in the duodenal juice only. These results demonstrate that toxification of EAs in the intestinal tract should be taken into consideration.
Deacetyl tenuazonic acid
(2009)
Als Folge der industriellen Produktion und der vielfältigen industriellen Nutzung von organischen Lösungsmitteln sind eine Vielzahl von Edukten, Zwischen- und Endprodukten in die Umwelt eingetragen worden und führen zu massiven Verunreinigungen des Bodens und des Grundwassers. Die Untersuchung und Sanierung des Grundwassers stellt einen aktuellen Schwerpunkt in der Altlastenbearbeitung dar. Vielfach werden klassische pump & treat-Verfahren zur Grundwassersanierung verwendet. Diese aktiven Sicherungs- und Sanierungsmaßnahmen werden jedoch unter dem Gesichtspunkt der Verhältnismäßigkeit häufig als ineffizient eingeschätzt. Als Alternative sollen die natürlichen Abbauprozesse im Grundwasserleiter genutzt oder gezielt verstärkt werden, um auf diesem Weg eine in-situ-Sanierung des Grundwasserleiters zu erreichen. In den letzten Jahren haben sich verschiedene Sanierungsverfahren etabliert, bei denen durch die Zugabe von Hilfsstoffen die mikrobiologische Aktivität des Aquifers erhöht wird bzw. Stoffe zugeführt werden, die mit den Schadstoffen reagieren (in-situ chemische Oxidation bzw. Reduktion, ISCO). An ausgewählten Standorten ist auch die aktive Sanierung (pump & treat, on-site- Sanierung) mit biologischem Schadstoffabbau (Bio-Filter) kombiniert worden. Um den Sanierungsverlauf zu verfolgen und zu optimieren, ist die Beprobung von Grundwasser aus dem Grundwasserleiter oder aus laufenden Anlagen erforderlich. In Fällen der gesteigerten mikrobiologischen Aktivität des Grundwassers treten gehäuft Probleme bei der Stabilisierung der Wasserproben auf. Die forcierten Abbauprozesse der Schadstoffe gehen nach der Probenahme in der Probenflasche weiter, bis die Energiebasis der Mikrobiologie aufgebraucht ist. Durch eine geringe Temperaturerhöhung beschleunigen sich diese Prozesse zusätzlich. In der Folge können die Schadstoffgehalte teilweise innerhalb weniger Stunden stark reduziert werden. Im Analysenlabor wird dann ein Schadstoffgehalt nachgewiesen, der nicht mehr die Verhältnisse im Aquifer bzw. im Ablauf der Reinigungsstufen widerspiegelt. Eine Einschätzung des Sanierungsfortschritts oder der Reinigungsleistung ist unter diesen Bedingungen stark fehlerbehaftet und kann zu groben Fehlinterpretationen führen. Grundwasserproben, die einem Aquifer mit hoher natürlicher oder initiierter mikrobiologischer Abbauaktivität entstammen, müssen daher zusätzlich stabilisiert werden, um den Ist-Zustand zum Zeitpunkt der Probenahme zu erfassen. Die Konservierung von Wasserproben bei der Probenahme von Grundwasser ist in der Normung umfangreich beschrieben: Die EN ISO 5667-3 von 2004 ist im Normausschuss (NA 119-01-03-01-01) überarbeitet und 2012 als Norm verabschiedet worden (EN ISO 5667-3, 03.12, deutsche Fassung DIN EN ISO 5667-3, 03-2013) [1], In Einzelfällen hat sie sich nicht als ausreichend erwiesen, um die Stabilität der organischen Schadstoffe in den oben beschriebenen Wasserproben zu gewährleisten.
The design and operation of an observational study on the profiles of volatile organic compounds (VOC) in the breath of 37 lung cancer patients and 23 healthy controls of similar age is outlined. The necessity to quantify each VOC considered as potential disease marker on basis of individual calibration is elaborated and the quality control measures required to maintain reproducibility in breath sampling and subsequent instrumental trace VOC analysis using SPME-GC-MS over a study period of 14 months are described. 24 VOC were quantified on basis of their previously suggested potential as cancer markers. The breath concentration levels of aromatic compounds was expectedly increased in smokers while lung cancer patients displayed significantly increased levels of oxygenated VOC such as aldehydes, 2-butanone and 1-butanol. Though sets of selected oxygenated VOC displayed sensitivities and specificities between 80 and 90% using linear discriminant analysis with leave-one-out cross validation the effective selectivity of the breath VOC approach with regard to cancer detection is clearly limited. Results were discussed against the background of the literature on volatile cancer marker investigations and the prospects to link increased VOC levels in patients’ breath with approaches to employ sniffer dogs. Experiences from this study and the literature suggest that the current state of breath VOC based discrimination between cancer patients and healthy controls is hardly improvable. Observational studies tend to observe significant differences mostly in levels of certain oxygenated VOC but without resolution required for practical application. Any step towards practicable exploitation of VOC profile differences for illness detection would have to solve current restrictions set by the low and variable VOC concentrations. Further challenges are the technical complexity of studies involving breath sampling and possibly the limited capability of current analytical procedures to detect instable marker candidates.
Commercially available linear alkylbenzenesulfonates (LASs) are a mixture of various homologues and isomers, leading to 20 major species. In this work we investigated the commercial product by liquid chromatography-solid phase extraction-nuclear magnetic resonance spectroscopy-mass spectrometry (LC-SPE-NMR/MS). The commercial product was separated into 17 fractions by liquid chromatography (LC). After chromatographic separation, 5% of the flow was split to a mass spectrometer (MS) while 95% was send to post-column solid phase extraction cartridges for enrichment of the analytes (LC-SPE). After elution from the SPE-cartridges a NMR-spectrometer equipped with a cryo-probe was used for the characterisation of the different LASs species. For the first time H-1-1D and H-H-COSY spectra for 14 LASs species out of 20 major isomers are presented, whereas the 6 remaining species are detected as mixtures in 3 H-1-1D and H-H-COSY spectra. These data were used to correlate the chromatographic retention of the LASs isomers to the substitution pattern of the alkyl chain.
The international research project HYCREF, funded by the European Commission in the 5 th Framework programme, aimed to develop methods to prepare homogenous and stable water-, soiland waste reference materials contaminated with mineral oil hydrocarbons and to test certify the mineral oil content by gas chromatographic methods. As mineral oil products are important sources for environmental contaminations a high need exists for certified reference materials for their determination using the new gas chromatographic methods (soil: ISO/FDIS 16703, waste: ENpr 14039, water: ISO 9377-2). The experimental conditions and results for preparation and characterisation of a total of nine reference materials (3 water-, 3 soil- and 3 waste materials) are described and discussed. Target values for the reference materials were defined at the beginning of the project in order to have clear quality criteria, which could be compared with the achieved results at the end of the project. These target specifications were related to the maximum uncertainty from test certification exercises (< 5 % for soil/waste and < 10 % for water), the maximum inhomogeneity between bottles (< 3 %) and minimum requirements for stability (> 5 years for soil/waste and > 2 years for water). The feasibility studies showed that solid materials (soil, waste) could be prepared sufficiently homogenous and stable. The test certified values of the 6 solid materials comprise a wide range of mineral oil content from about 200-9000 mg/kg with expanded uncertainties between 5.7-13.1 % using a coverage factor k (k = 2). The development of new water reference materials –the so-called “spiking pills” for an offshore- and a land-based discharge water represents one of the most innovative aspects of the project. The spiking pill technology facilitates the application and storage and improves the material stability compared with aqueous materials. Additional to the preparation and test certification of the reference materials investigations on the analytical method for the determination of mineral oil hydrocarbons were performed. The results obtained in relation to the optimisation of analytical method (extraction procedure, sample pretreatment, clean-up and measurement) were provided to the respective working group of ISO/TC 190, ISO/TC 147 and CEN/TC 292 and were incorporated into the ongoing standardisation procedures. The new version of ISO/FDIS 16703 (July 2004) includes the improvements based on HYCREF results, for example the increase of the solvent/sample ratio, the removal of acetone from the organic extracts and the use of column technique instead of batch technique for clean-up.
Mycotoxins are important non-anthropogenic food and feed contaminants, which can be present on almost every agricultural commodity. Effective consumer protection therefore essentially depends on food surveillance by reliable quantitative analysis enabled by appropriate quality control. Certified (matrix) reference materials (CRMs) are versatile tools to support Quality assurance. However, in the case of ochratoxin A (OTA), a hepato- and nephrotoxic mycotoxin, which is regulated in various foods, there is a lack of suitable CRMs. This lack has now been overcome by the development of two European Reference Materials (ERM®) for the Determination of OTA in roasted coffee (ERM®-BD475) and red wine (ERM®-BD476). This article discusses the material preparation process as well as the results of homogeneity and stability testing. Furthermore, the results of the inhouse certification studies carried out at BAM Federal Institute for Materials Research and Testing are presented and discussed. Interlaboratory comparison studies involving selected expert laboratories with documented Expertise in the field of mycotoxin analysis were conducted to confirm the certified values determined by BAM. The certified ochratoxin A values and their corresponding expanded uncertainties (k = 2) were assigned in full compliance with the requirements of ISO Guide 35 and are as follows:
(6.0 ± 0.6) µg kg-1 for roasted coffee, ERM®-BD475, and (0.52 ± 0.11) µg L-1 for red wine, ERM®-BD476.
1,2,5,6,9,10-hexabromocyclododecane (HBCD), a widely used flame retardant, is an ubiquitous contaminant in
the environment. Still, only little is known about the distribution and behavior in the environment such as
bioaccumulation or biotransformation of HBCD stereoisomers. In order to investigate enrichment and possible
bioisomerization of HBCD stereoisomers, Mirror Carps were exposed to pure (+)- and (-)-γ-HBCD, randomly
sampled after a predefined specific period and subjected to enantiomer-specific determination of α-, β-, and γ-