Filtern
Dokumenttyp
- Zeitschriftenartikel (9)
- Posterpräsentation (8)
- Vortrag (5)
- Beitrag zu einem Tagungsband (3)
- Forschungsbericht (1)
Schlagworte
- Analytik (3)
- Water Framework Directive (3)
- Brandbeschleuniger (2)
- Fire debris (2)
- Gesamtwasserprobe (2)
- Ignitable liquids (2)
- Reference materials (2)
- Tributyltin (2)
- Wasserrahmenrichtlinie (2)
- Water framework directive (2)
- Whole water sample (2)
- Accelerant (1)
- Adsorption (1)
- Aluminium (1)
- Arson analysis (1)
- Bottles (1)
- Brand (1)
- Brandgase (1)
- Chemical analysis (1)
- Cone calorimeter (1)
- European Water Framework Directive (1)
- Experimental design (1)
- Fire behavior (1)
- Fluorinated polyethylene (1)
- Forensic science (1)
- Gas chromatography (1)
- Glass (1)
- Heat release (1)
- Hydrophobic organic pollutants (1)
- Interlaboratory comparison (1)
- Isotope dilution (1)
- Organotin compounds (1)
- PAH (1)
- PBDE (1)
- Partikel (1)
- Rauchgase (1)
- Rauchgastemperaturen (1)
- Raumbrand (1)
- Raumbrände (1)
- Reference material (1)
- Reference method (1)
- Referenzmaterial (1)
- Ringversuch (1)
- Room fire test (1)
- Slurry (1)
- Smoke density chamber (1)
- Solid phase microextraction (1)
- Solid-phase extraction (1)
- Solid-phase microextraction (1)
- Suspended particulate matter (1)
- TBT (1)
- Temperatures (1)
- Toxicity (1)
- Whole water (1)
- Whole water body (1)
- Wärmefreisetzung (1)
Eingeladener Vortrag
- nein (5)
Anhand von 5 verschiedenen Zimmerbrandversuchen wurde der Einfluss von Brandbeschleunigern auf den Brandverlauf experimentell untersucht. Es wurden verschiedene brandtechnologische Kennwerte, wie der Massenverlust des gesamten Brandraums, Brandraumtemperaturen, die Wärmefreisetzungen sowie die Rauchgasemissionen ermittelt und beurteilt. Die Rauchgasanalyse erfolgte im Schlot, im Brandraum sowie in der Brandraumöffnung mittels Fourier Transformierte Infrarot-FTIR-Spektroskopie. Neben diesen brandtechnologischen Untersuchungen erfolgten auch chemisch-analytische Untersuchungen nach dem Brand, mit dem Ziel, den eingesetzten Brandbeschleuniger nachzuweisen. Im Anschluss an die jeweiligen Zimmerbrandversuche wurden verschiedene Brandrückstandsproben aus dem Brandschutt, Wischproben von den Wänden und den übriggebliebenen Gegenständen sowie Proben in Form von Adsorbensmaterialien und Tenax-Röhrchen genommen und mit Hilfe der HSSPME-GC-MS-Methode (Headspace-Solid Phase Micro Extraction-Gas Chromatographie-Massenspekrometrie) in Hinblick eines möglichen Brandbeschleunigernachweis analysiert.
The influence of fire accelerants on the fire behavior during living room fires was experimentally investigated by performing 5 different room fire scenarios. During the tests flre-technological quantities were determined as well as chemical-analytical studies were carried out. The focus was on the detection of smoke gases and the proof of used fire accelerants. The evaluation of traceable fire accelerants and the reconstruction of the fire development are based on a precise Chemical analysis of the combustion products.
In this work an innovative methodology was developed to combine available analyticai techniques to draw conclusions from solid, liquid and gaseous fire residues about the fire process. Each ofthe fire rooms was equipped with the same living room inventory. The location and amount of fire accelerant (a mixture of diesel/gasoline) differed in 4 of 5 tests. Orte room fire experiment was carried out without fire accelerant.
The following fire technological characteristics were determined during the room fire experiments: mass loss (of the complete room), temperatures (at several locations in the room), heat release and smoke gas emission (measured at three different locations: in the chimney, in the fire room and at the door opening).
While the smoke gases were analysed by using Fourier Transform Infrared spectroscopy, the fire residues and swipe samples (particles) were examined by Headspace-Solid Phase Microextraction-
Gaschromatography-Mass spectrometry. These procedures make it possible to detect low concentrations of volatile components of the fire accelerants. The Chemical analyticai results of the fire accelerant detection are presented.