Clear evidence of the effects caused by hydrogen, introduced in different forms in an analytical glow discharge source (GDS) operated with argon, is presented for the different matrix elements copper, stainless steel, titanium, aluminium and silicon. When hydrogen is present even in small quantities in argon, not only are there significant changes in the emission line intensities of most elements (analyte and plasma species), but also new spectral features, such as emission bands of new compounds (hydrides of sputtered sample constituents) and a continuous background in the range ~220440 nm. Moreover, the discharge current (the dependent parameter in our experiments) decreases with increasing hydrogen concentration. Different modes of hydrogen introduction, externally in gaseous form or sputtered as a sample constituent, cause very similar effects in terms of discharge current, line intensity (of analyte and plasma gas) and emission continua, which implies similar changes in the discharge processes in the two cases. The excitation of the hydrogen continuum appears to quench the population of the argon metastables (11.55 and 11.72 eV) and, consequently, other elementary processes in the plasma in which the argon metastables take part, but to a different extent for each analyte.
The influence of hydrogen contained in a sample or otherwise introduced into a glow discharge source (GDS) is here extensively experimentally presented for the case of copper as a sample by means of the addition of small quantities of molecular hydrogen (<1% relative partial pressure) to the argon carrier gas. The progressive addition of molecular hydrogen causes different intensity changes particular to the individual lines of different species such as atomic (Cu I) and ionic (Cu II) copper, and also atomic (Ar I) and ionic (Ar II) argon. Some interesting features of the emission spectrum of hydrogen such as its line, band and even continuum spectrum are observed. It was also found that the depth resolution becomes worse even at very low concentrations of hydrogen.
Depth profiling of electrically non-conductive layered samples by RF-GDOES and HFM plasma SNMS
(2001)
The work is intended to compare the capabilities of two similar depth profiling techniques to analyse electrically non-conductive samples. In order to get a better evaluation of the depth resolution, various multilayer sandwiches, such as SiO2/TiO2 and Si3N4/SiO2 deposited on glass substrates have been investigated. Optimised depth profiles are presented for both methods, glow discharge optical emission spectrometry (GDOES) and radiofrequency mode (known as HFM in the SNMS literature) of plasma secondary neutral mass spectrometry (SNMS). The optimisation procedure, necessary to get the best set of plasma parameters, which result in the optimal depth resolution, is also described for one selected sample. Additionally, sputtering crater profilometry was carried out in order to check out the flatness of the sputtered crater. The influence of the thickness of the sample substrate on the sputtering rate is discussed. Finally, advantages and disadvantages of the use of these two depth profiling methods, especially for the non-conductive samples, are concluded from this comparative study. Time-of-flight secondary ion mass spectrometry (ToF-SIMS) analysis of a cross-sectioned sample was carried out in order to get supplementary information.
In order to gain an insight into the numerous effects caused by the addition of hydrogen to an argon glow discharge, comparison experiments have been made with neon as carrier gas. In some cases the effects are diminished or even disappear. Using various bulk samples, such as copper, steel and titanium, sputtered in a neon glow discharge, the intensities of the analytical lines are affected by the presence of hydrogen in different ways from argon; the dependent parameter (the discharge current in this work) and the sputtering rate vary less than in argon. The crater shape and roughness are also affected and these effects are discussed qualitatively. Probably the most important spectral feature caused by hydrogen in the case of a discharge in argon is the emission of a continuous background. This does not appear in neon under similar discharge conditions and only weakly at high hydrogen concentrations. This supports the suggestion, made in previous work, that an effective quenching process of the argon metastables (11.55 and 11.72 eV) is Penning excitation of the hydrogen molecules, and subsequent decay to a repulsive state with emission of the continuum; in neon the energy match does not occur. It was found with neon, as with argon, that similar features occur as when hydrogen is introduced in different ways into the glow discharge: as a molecular gas contamination or as a constituent of the sample. Glow discharge mass spectrometry (GD-MS) experiments carried out with both argon and neon support the results obtained by optical emission spectrometry (OES) and provide further relevant information.
The scope of this paper is to illustrate the need for an improved quality assurance in fluorometry. For this purpose, instrumental sources of error and their influences on the reliability and comparability of fluorescence data are highlighted for frequently used photoluminescence techniques ranging from conventional macro- and microfluorometry over fluorescence microscopy and flow cytometry to microarray technology as well as in vivo fluorescence imaging. Particularly, the need for and requirements on fluorescence standards for the characterization and performance validation of fluorescence instruments, to enhance the comparability of fluorescence data, and to enable quantitative fluorescence analysis are discussed. Special emphasis is dedicated to spectral fluorescence standards and fluorescence intensity standards.
The need for the traceable characterization of fluorescence instruments is emphasized from a chemists point of view, focusing on spectral fluorescence standards for the determination of the wavelength- and polarization-dependent relative spectral responsivity and relative spectral irradiance of fluorescence measuring systems, respectively. In a first step, major sources of error of fluorescence measurements and instrument calibration are revealed to underline the importance of this issue and to illustrate advantages and disadvantages of physical and chemical transfer standards for generation of spectral correction curves. Secondly, examples for sets of traceable chemical emission and excitation standards are shown that cover a broad spectral region and simple procedures for the determination of corrected emission spectra with acceptable uncertainties are presented. With proper consideration of the respective measurement principle and geometry, these dye-based characterization procedures can be not only applied to spectrofluorometers but also to other types of fluorescence measuring systems and even to Raman spectrometers.
A Round Robin (RR) exercise on selected coated materials has been carried out with the aim of finding the optimal conditions for the analysis of nitride layers with GD-OES. Such pre-normative work is necessary for the evaluation of parallel development of the production of nitride layers as certified reference materials (CRMs). Two types of samples, TiN layer and VN layer, respectively, with chemical compositions close to stoichiometry and a thickness of ~3 µm, deposited on a steel substrate, have been provided to the RR participants. Additionally, another type of sample, a (100 nm CrNi/100 nm Cu) multilayer (ML) stack deposited on silicon wafer has also been included in the RR. This sample can be used as a CRM for checking GD spectrometer conditions and it has been proved helpful in further development of GDS instrumentation and methodology. The RR exercise has been performed in the frame of the EC Thematic Network on Glow Discharge Spectroscopy for Spectrochemical Analysis (GDS-Net).