Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (9)
- Beitrag zu einem Tagungsband (7)
- Beitrag zu einem Sammelband (4)
- Vortrag (1)
- Sonstiges (1)
- Posterpräsentation (1)
- Forschungsbericht (1)
Schlagworte
- Beton (4)
- Concrete (4)
- Monitoring (4)
- Ultraschall (4)
- Brücke (3)
- Condition assessment (3)
- Fundament (3)
- Impulse radar (3)
- LAUS (3)
- Non-Destructive Testing (3)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (1)
A toolbox with non-destructive testing methods for the condition assessment of railway bridges
(2006)
The unified economic structure of the European market requires a unified transport infrastructure to ensure seamless and barrierfree transportation of passengers and goods. The European commission is funding the European Integrated Project Sustainable Bridges to comply with future traffic demands. The main objective of the project is to reliably assess and upgrade the bridge infrastructure for the required increase of axle loads and transport volume. 32 Institutes from 12 countries develop unified procedures for the assessment and improvement of the existing railway bridge stock under the guidance and review of six major European railway companies.
Non destructive testing (NDT) is given a high priority. One of the work packages concentrates on the potential of advanced NDT-methods and creates a toolbox with advisable methods for the condition assessment of all types of railway bridges. Although NDT-methods are implemented in the quality assurance process in many industries, their application in the railway infrastructure is not common. Only a few countries have included selected NDT-methods into advanced condition assessment procedures for the management of their bridge stock.
This paper describes also current activities to enhance pulse-phase thermography, impulse-radar and acoustic methods. The advanced methods enable infrastructure owners to verify construction plans, to assess structures, repair and strengthening quality or to identify in-service damages. Latest development is an automated scanning system for combined acoustic and electromagnetic measurements. The results are then combined through data fusion techniques to further increase their value for the bridge owners.
The European infrastructure asset has developed historically and is characterized by nation-specific construction processes. Inspection, condition assessment, and maintenance procedures differ from country to country. Because of historical and political circumstances, national infrastructure assets are maintained at different levels, too. Since the budget for maintaining the bridge infrastructure less and less meets the demands of a growing bridge stock, bridge inspection, maintenance, and life-cycle considerations gain higher importance. The need exists to develop effective diagnosis tools for early detection of construction faults, defects, and deterioration processes during inspection, to keep the bridge infrastructure at an acceptable level, from structural safety and economic viewpoints. An overview on the latest research projects and integrated bridge management systems in Europe is given. The potentials of nondestructive testing (NDT) are presented, with special focus on technical advances of NDT applications to reinforced concrete (RC) and posttensioned concrete bridges. Although NDT is not regularly integrated in these processes, the application brings valuable information on the current condition of the inner structure in called-in special inspections. NDT-automation and the application of imaging echo methods, combined with advanced data processing, produce a surprising level of information about the inner structure of massive RC slabs up to a depth of about 60 cm. Detected inhomogeneity and scatterers of acoustic or electromagnetic waves can be visualized in vertical or horizontal slices through the structure or animations. The fusion of different three-dimensional data sets of processed data improves the interpretability and accuracy of the results.
Charakterisierung von Feuchte- und Salzbelastungen in Baumaterial durch Impedanzspektroskopie
(2006)
Coda Wave Interferometry (CWI), a method to evaluate subtle changes of elastic wave velocity in a medium, has been proven to be effective to detect small changes or ultrasonic velocity in concrete caused by load, temperature, moisture, damage or other means. While classical CWI is just able to determine velocity changes globally in relatively large areas between and around pairs of transmitters and receivers, several approaches have been proposed to identify the area affected by the changes more precisely. Most of them are based on the calculation of sensitivity kernels for de-correlation of signals measured at a specific state against a reference. Others follow simplified approaches. In a laboratory setup a concrete specimen of 1:5 x 1:5 x 0:5 m3 was compressed at a certain point. Maximum loads of 20 to 100 kN have been applied in 5 to 10 kN steps in various cycles. The specimen is equipped with 18 embedded ultrasonic broadband piezo transceivers (60 kHz central frequency). Ten of these receivers have been connected to a multiplexer and ultrasonic transmitting and receiving equipment in a way that allowed almost continuous two way measurements between all sensor pairs. Even simple ways to evaluate the data (e.g. crosscorrelation between signals at different load states) allowed pinpointing the load center at least approximately. A more detailed data evaluation either using CWI or even more one of the more sophisticated localization algorithms gave “sharper” results in terms of localization and a better correlation between load and velocity change/de-correlation. The results are used in upcoming monitoring systems for concrete structures.
This paper presents a novel non-destructive testing and health monitoring system using a network of tactile transducers and accelerometers for the condition assessment and damage classification of foundation piles and utility poles. While in traditional pile integrity testing an impact hammer with broadband frequency excitation is typically used, the proposed testing system utilizes an innovative excitation system based on a network of tactile transducers to induce controlled narrow-band frequency stress waves. Thereby, the simultaneous excitation of multiple stress wave types and modes is avoided (or at least reduced), and targeted wave forms can be generated. The new testing system enables the testing and monitoring of foundation piles and utility poles where the top is inaccessible, making the new testing system suitable, for example, for the condition assessment of pile structures with obstructed heads and of poles with live wires. For system validation, the new system was experimentally tested on nine timber and concrete poles that were inflicted with several types of damage. The tactile transducers were excited with continuous sine wave signals of 1 kHz frequency. Support vector machines were employed together with advanced signal processing algorithms to distinguish recorded stress wave signals from pole structures with different types of damage. The results show that using fast Fourier transform signals, combined with principal component analysis as the input feature vector for support vector machine (SVM) classifiers with different kernel functions, can achieve damage classification with accuracies of 92.5% ± 7.5%.
Recently developed new transducers for ultrasonic transmission, which can be embedded right into concrete, are now used for non-destructive permanent monitoring of concrete. They can be installed during construction or thereafter. Large volumes of concrete can be monitored for changes of material properties by a limited number of transducers. The transducer design, the main properties as well as installation procedures are presented. It is shown that compressional waves with a central frequency of 62 kHz are mainly generated around the transducer's axis. The transducer can be used as a transmitter or receiver. Application examples demonstrate that the transducers can be used to monitor concrete conditions parameters (stress, temperature,
) as well as damages in an early state or the detection of acoustic events (e.g., crack opening). Besides application in civil engineering our setups can also be used for model studies in geosciences.
Ultrasonic echo and transmission techniques are used in civil engineering on a regular basis. New sensors and data processing techniques have lead to many new applications in the structural investigation as well as quality control. But concrete structures in the nuclear sector have special features and parameters, which pose problems for the methods and instrumentation currently available, e.g. extreme thickness, dense reinforcement, steel liners or special materials. Several innovative ultrasonic techniques have been developed to deal with these issues at least partly in lab experiments and pilot studies. Modern imaging techniques as multi-offset SAFT have been used e. g. to map delaminations. Thick concrete walls have successfully been inspected, partly through a steel liner. Embedded ultrasonic sensors have been designed which will be used in monitoring networks of large concrete structures above and below ground. In addition, sensitive mathematical methods as coda wave interferometry have been successfully evaluated to detect subtle changes in material properties. Examples of measurements and data evaluation are presented.
LAUS - Erste praktische Erfahrungen mit einem neuartigen Ultraschallsystem großer Eindringtiefe
(2018)
Konventionelle Systeme zur Ultraschall-Echo-Prüfung von Betonbauteilen sind in ihrer Eindringtiefe auf etwa einem Meter begrenzt. Zur Prüfung stärkerer Objekte war die Entwicklung eines neuartigen Prüfsystems notwendig. Das LAUS-System (Large Aperture UltraSound) besteht aus 12 einzelnen Arrays, die mit jeweils 32 Einzelprüfköpfen (Scherwellen, 25 – 50 kHz) als Sender oder Empfänger betrieben werden können. Sie werden unabhängig auf Betonoberflächen mit Unterdruck befestigt und kommunizieren drahtlos untereinander und mit der Zentraleinheit. Alle möglichen Kombinationen ergeben 132 Einzelmessungen, die zur Rekonstruktion des durchschallten Volumens genutzt werden. Mehrere dieser Datensätze lassen sich zu einer 3D-Auswertung kombinieren. Das System wurde an mehreren Testobjekten und Bauwerken erfolgreich erprobt. So konnte die fünf Meter dicke, sehr stark bewehrte Fundamentplatte des Fallturms auf dem BAM-Testgelände bei Horstwalde durchschallt werden. Ein zweites Beispiel ist die erfolgreiche Detektion von Spannkanälen in 1,8 m Tiefe in einem massiven Brückenbauwerk.