The LAUS: First Applications of a New System for Ultrasonic Imaging of Very Concrete Structures
(2019)
The LAUS (Large Aperture Ultrasonic System) has been developed to image very thick concrete structures, which are not accessible for commercial systems. The device and the corresponding software is the result of joint Research of BAM, an ultrasonic instrument manufacturer and University of Kassel, Germany. It consists of 12 separate Arrays of 32 point-contact shear wave transducers each, which can be deployed in flexible configurations. Each array is combined with battery and transmitter, receiver and wireless communication electronics.
Three case histories are presented. First the system was deployed on a 5-m thick heavily reinforced foundation slab.
The reflection of the slab’s bottom was imaged clearly. In addition, a multiple reflection was registered, thus giving hope that even thicker elements might be imaged by the instrument. Second, the LAUS was used to investigate a massive bridge girder where a heavy rainstorm during concreting had led to imperfections that were visible after removing the formwork was removed. The LAUS could image tendon ducts in 1.8m depth and the backwall closely behind them. Some limited areas showed blurred reflections and were checked by drill holes; these areas were affected by diffuse damage which could be repaired by injections. Third, a large retaining wall was checked for thickness.
Meanwhile, the LAUS has been used in underground waste deposits (nuclear and other) for quality assurance of sealing plugs. A confirmed penetration depth of about 7 m has been reached.
A toolbox with non-destructive testing methods for the condition assessment of railway bridges
(2006)
The unified economic structure of the European market requires a unified transport infrastructure to ensure seamless and barrierfree transportation of passengers and goods. The European commission is funding the European Integrated Project Sustainable Bridges to comply with future traffic demands. The main objective of the project is to reliably assess and upgrade the bridge infrastructure for the required increase of axle loads and transport volume. 32 Institutes from 12 countries develop unified procedures for the assessment and improvement of the existing railway bridge stock under the guidance and review of six major European railway companies.
Non destructive testing (NDT) is given a high priority. One of the work packages concentrates on the potential of advanced NDT-methods and creates a toolbox with advisable methods for the condition assessment of all types of railway bridges. Although NDT-methods are implemented in the quality assurance process in many industries, their application in the railway infrastructure is not common. Only a few countries have included selected NDT-methods into advanced condition assessment procedures for the management of their bridge stock.
This paper describes also current activities to enhance pulse-phase thermography, impulse-radar and acoustic methods. The advanced methods enable infrastructure owners to verify construction plans, to assess structures, repair and strengthening quality or to identify in-service damages. Latest development is an automated scanning system for combined acoustic and electromagnetic measurements. The results are then combined through data fusion techniques to further increase their value for the bridge owners.
Charakterisierung von Feuchte- und Salzbelastungen in Baumaterial durch Impedanzspektroskopie
(2006)
Coda Wave Interferometry (CWI), a method to evaluate subtle changes of elastic wave velocity in a medium, has been proven to be effective to detect small changes or ultrasonic velocity in concrete caused by load, temperature, moisture, damage or other means. While classical CWI is just able to determine velocity changes globally in relatively large areas between and around pairs of transmitters and receivers, several approaches have been proposed to identify the area affected by the changes more precisely. Most of them are based on the calculation of sensitivity kernels for de-correlation of signals measured at a specific state against a reference. Others follow simplified approaches. In a laboratory setup a concrete specimen of 1:5 x 1:5 x 0:5 m3 was compressed at a certain point. Maximum loads of 20 to 100 kN have been applied in 5 to 10 kN steps in various cycles. The specimen is equipped with 18 embedded ultrasonic broadband piezo transceivers (60 kHz central frequency). Ten of these receivers have been connected to a multiplexer and ultrasonic transmitting and receiving equipment in a way that allowed almost continuous two way measurements between all sensor pairs. Even simple ways to evaluate the data (e.g. crosscorrelation between signals at different load states) allowed pinpointing the load center at least approximately. A more detailed data evaluation either using CWI or even more one of the more sophisticated localization algorithms gave “sharper” results in terms of localization and a better correlation between load and velocity change/de-correlation. The results are used in upcoming monitoring systems for concrete structures.
LAUS - Erste praktische Erfahrungen mit einem neuartigen Ultraschallsystem großer Eindringtiefe
(2018)
Konventionelle Systeme zur Ultraschall-Echo-Prüfung von Betonbauteilen sind in ihrer Eindringtiefe auf etwa einem Meter begrenzt. Zur Prüfung stärkerer Objekte war die Entwicklung eines neuartigen Prüfsystems notwendig. Das LAUS-System (Large Aperture UltraSound) besteht aus 12 einzelnen Arrays, die mit jeweils 32 Einzelprüfköpfen (Scherwellen, 25 – 50 kHz) als Sender oder Empfänger betrieben werden können. Sie werden unabhängig auf Betonoberflächen mit Unterdruck befestigt und kommunizieren drahtlos untereinander und mit der Zentraleinheit. Alle möglichen Kombinationen ergeben 132 Einzelmessungen, die zur Rekonstruktion des durchschallten Volumens genutzt werden. Mehrere dieser Datensätze lassen sich zu einer 3D-Auswertung kombinieren. Das System wurde an mehreren Testobjekten und Bauwerken erfolgreich erprobt. So konnte die fünf Meter dicke, sehr stark bewehrte Fundamentplatte des Fallturms auf dem BAM-Testgelände bei Horstwalde durchschallt werden. Ein zweites Beispiel ist die erfolgreiche Detektion von Spannkanälen in 1,8 m Tiefe in einem massiven Brückenbauwerk.