Filtern
Dokumenttyp
- Posterpräsentation (7)
- Zeitschriftenartikel (6)
- Vortrag (4)
- Beitrag zu einem Tagungsband (2)
Sprache
- Englisch (19)
Referierte Publikation
- nein (19) (entfernen)
Schlagworte
- Tomography (7)
- BAMline (6)
- X-ray imaging (6)
- Neutron imaging (3)
- Additive manufacturing (2)
- Debye-Waller-Faktor (2)
- Li-ion battery (2)
- Synchrotron X-ray computed tomography (2)
- X-ray tomography (2)
- Absorption edge tomography (1)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (17)
- 8.5 Röntgenbildgebung (17)
- 5 Werkstofftechnik (2)
- 5.4 Multimateriale Fertigungsprozesse (2)
- 9 Komponentensicherheit (2)
- 9.4 Integrität von Schweißverbindungen (2)
- 3 Gefahrgutumschließungen; Energiespeicher (1)
- 3.1 Sicherheit von Gefahrgutverpackungen und Batterien (1)
- 6 Materialchemie (1)
- 6.3 Strukturanalytik (1)
Eingeladener Vortrag
- nein (4)
Toughening mechanisms and enhanced damage tolerant fatigue behaviour in laminated metal composites
(2022)
In the present study, fatigue crack growth (FCG) in a laminated metal composite (LMC) consisting of Al-based constituents with dissimilar strength was studied. Additionally, the FCG in both monolithic constituent materials was determined and a linear elastic rule of mixture (ROM) concept was calculated as a reference for the FCG of the laminated composite. Crack networks in the laminates were analyzed post-mortem by means of light microscopy and synchrotron X-Ray tomography (SXCT). Significantly reduced FCG rates for the LMC were found at elevated stress intensity ranges compared to both the monolithic constituents as well as the ROM concept. This is the result of the formation of a complex 3D crack network in the laminated architecture caused by the appearance of the two different toughening mechanisms a) crack deflection and b) crack bifurcation at the vicinity of the interfaces.
The availability of high-performance Al alloys in AM is limited due to difficulties in printability, requiring both the development of synergetic material and AM process to mitigate problems such as solidification cracking during laser powder bed fusion (LPBF). The goal of this work was to investigate the failure mechanism in a LPBF 7017 Aluminium alloy + 3 wt% Zr + 0.5 wt% TiC. The processing leads to different categories of Zr-rich inclusions, precipitates and defects.
A recent upgrade of key equipment of the BAMline widens its imaging capabilities: shorter scan acquisition times are now possible, in situ and operando studies can now be routinely performed, and different energy spectra can easily be set up. In fact, the upgraded double-multilayer monochromator brings full flexibility by yielding different energy spectra to optimize flux and energy resolution as desired.
Synchrotron X-Ray computed tomography at the BAMline is constantly evolving. During monochromatic tomographic scans a preview reconstruction is offered. Newly introduced scanning schemes suppress certain types of reconstruction artifacts. Additionally, the application of a pink beam enables for faster tomographic scans even within seconds.
After a general presentation of the beamline, specifically the workflow for ex-situ CT at BAMline is presented. Although being used in a broad variety of research fields the usual workflow for CT experiments is in most cases similar in terms of sample mounting, tomographic scan and reconstruction. Specific scanning schemes allow for a preview reconstruction carried out during the scan. A detailed description of the used hardware as well as the self-coded programs applied in the data pipeline will be given. This will be accompanied by a practical demonstration of the software involved in the entire process.
The ability to track electrode degradation, both spatially and temporally, is fundamental to understand performance loss during operation of lithium batteries. X-ray computed tomography can be used to follow structural and morphological changes in electrodes; however, the direct detection of electrochemical processes related to metallic lithium is difficult due to the low sensitivity to the element. In this work, 4-dimensional neutron computed tomography, which shows high contrast for lithium, is used to directly quantify the lithium diffusion process in spirally wound Li/SOCl2 primary cells. The neutron dataset enables the quantification of the lithium transport from the anode and the accumulation inside the SOCl2 cathode to be locally resolved. Complementarity between the collected neutron and X-ray computed tomographies is shown and by applying both methods in concert we have observed lithium diffusion blocking by the LiCl protection layer and identified all cell components which are difficult to distinguish using one of the methods alone.
Electrochemical impedance spectroscopy (EIS) is a well-established method to analyze a polymer electrolyte membrane fuel cell (PEMFC). However, without further data processing, the impedance spectrum yields only qualitative insight into the mechanism and individual contribution of transport, kinetics, and ohmic losses to the overall fuel cell limitations. The distribution of relaxation times (DRT) method allows quantifying each of these polarization losses and evaluates their contribution to a given electrocatalyst's depreciated performances. We coupled this method with a detailed morphology study to investigate the impact of the 3D-structure on the processes occurring inside a high-temperature polymer electrolyte membrane fuel cell (HT-PEMFC). We tested a platinum catalyst (Pt/C), a platinum-cobalt alloy catalyst (Pt3Co/C), and a platinum group metal-free iron-nitrogen-carbon (Fe–N–C) catalyst. We found that the hampered mass transport in the latter is mainly responsible for its low performance in the MEA (along with its decreased intrinsic performances for the ORR reaction). The better performance of the alloy catalyst can be explained by both improved mass transport and a lower ORR resistance. Furthermore, single-cell tests show that the catalyst layer morphology influences the distribution of phosphoric acid during conditioning.
The neutron imaging instrument CONRAD was operated as a part of the user program of the research reactor BER‐II at Helmholtz‐Zentrum Berlin (HZB) from 2005 to 2020. The Instrument was designed to use the neutron flux from the cold source of the reactor, transported by a curved neutron guide. The pure cold neutron spectrum provided a great advantage in the use of different neutron optical components such as focusing lenses and guides, solid‐state polarizers, Monochromators and phase gratings. The flexible setup of the instrument allowed for implementation of new methods including wavelength‐selective, dark‐field, phase‐contrast and imaging with polarized neutrons. In summary, these developments helped to attract a large number of scientists and industrial customers, who were introduced to neutron imaging and subsequently contributed to the Expansion of the neutron imaging community.
The BAMline at the synchrotron X-ray source BESSY II (Berlin, Germany) is supporting researchers in a wide range of research areas since more than 20 years. These fields include biology, cultural heritage, medicine, and also materials science. As a non-destructive characterization method, synchrotron X-ray imaging, especially tomography with hard X-Rays, plays an important role in structural 3D characterization. A recent upgrade of key equipment at the BAMline expands the imaging capabilities towards shorter acquisition times. Therefore, in-situ and operando experiments can now be routinely conducted. Also, different energy resolutions can be set up to optimize flux and energy resolution as desired. This requires an adaptation of the used reconstruction methods in order to perform necessary analyses also during the experiment. In this presentation the equipment, data handling pipeline as well as various examples from material science are presented.
The BAMline at the 3rd generation synchrotron X-ray source BESSY II has been supporting researchers in a wide range of research areas for over 20 years. In addition to materials science, these fields also include biology, cultural heritage, and medicine. Being a non-destructive characterization method, synchrotron X-ray imaging, in particular tomography (SXCT), plays a particularly important role in structural characterization. A recent upgrade of key BAMline equipment expands the imaging capabilities: The upgraded dual multilayer monochromator offers flexibility by providing different energy spectra to optimize flux and energy resolution as desired. Different spectra (8 – 60 keV with ΔE/E 0.01%, 1.5%, 4% and pink beam) can be selected. The upgraded detector (in white beam configuration, equipped with an sCMOS camera) allows the higher flux to be exploited with reduced readout times. Shorter tomographic acquisition times in the range of seconds are now possible. Hence, in-situ and operando examinations are routinely available. An integrated slip ring allows continuous rotation of the sample stage for ease of wiring. The pink beam option allows tomographic observation of processes occurring in the time domain of a few seconds with a resolution down to ~ 1 µm. Different scan methods, optimized for quality and speed are available and discussed. Examples of energy related materials from fuel cell and battery research are shown.
An optional end station allows refraction enhanced imaging (synchrotron X-Ray refraction radiography (SXRR) and tomography (SXRCT)). That includes an analyzer Si-crystal in Bragg alignment between sample and detector. This technique obtains sensitivity to smaller structures (cracks, pores) down to a few wavelengths, while obtaining field of view sizes in the range of several mm. Besides medicine (e.g., teeth explants), several applications are found in material science, like studies on diesel particulate filters, ceramics, additively manufactured (AM) alloys and metal matrix composites (MMC). The in-situ capabilities include mechanical load (tension and compression) and heating up to 1100°C. A case study, the microstructural evolution during heat treatment of an AM AlSi10Mg, will be shown.