Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (89)
- Sonstiges (21)
- Beitrag zu einem Sammelband (11)
- Posterpräsentation (9)
- Beitrag zu einem Tagungsband (8)
- Vortrag (3)
- Forschungsbericht (1)
Schlagworte
- Synchrotron radiation (13)
- XRF (10)
- Synchrotron (8)
- XANES (7)
- BAMline (6)
- EXAFS (6)
- Gold (6)
- Radiography (6)
- Water transport (6)
- X-ray imaging (6)
- RFA (5)
- Röntgenfluoreszenzanalyse (5)
- Albrecht Dürer (4)
- Dental implants (4)
- Digital radiography (4)
- Microtomography (4)
- Platinum (4)
- Silberstiftzeichnung (4)
- Silverpoint drawing (4)
- X-ray fluorescence (4)
- X-ray spectrometry (4)
- XAFS (4)
- Implant-abutment interface (3)
- Local current distribution (3)
- Polymer electrolyte membrane fuel cell (PEMFC) (3)
- Resolution neutron-radiography (3)
- SAXS (3)
- SR-microXRF (3)
- Scintillator (3)
- Single-shot XAFS (3)
- Synchrotron X-ray imaging (3)
- Synchrotron instrumentation (3)
- Synchrotron radiography (3)
- Time resolution (3)
- X-ray optics (3)
- X-ray phase contrast (3)
- X-ray refraction (3)
- XAS (3)
- Adsorbates (2)
- Archaeometry (2)
- Archäometrie (2)
- Bragg magnification (2)
- CXC (2)
- Coherent imaging (2)
- Compound refractive lens (2)
- DRIFTS (2)
- Disorganized bone (2)
- Drawing (2)
- Drawings (2)
- Electrochromism (2)
- Fuel cell (2)
- Histology (2)
- Holotomography (2)
- Infrared spectroscopy (2)
- Local structure (2)
- Metallo-supramolecular polyelectrolytes (2)
- Micro-computed tomography (2)
- Nanoparticle (2)
- Non-destructive evaluation (2)
- Phase contrast (2)
- Quantification (2)
- Silica support (2)
- Speciation (2)
- Synchrotron-CT (2)
- Tomography (2)
- X-ray absorption spectroscopy (2)
- X-ray radiography (2)
- X-ray topography (2)
- XRF analysis (2)
- Zeichnungen (2)
- pnCCD (2)
- 2D/3D imageanalysis (1)
- 3D (1)
- 3D image analysis (1)
- AIMD simulation (1)
- Abdominal appendages (1)
- Abri Pataud (1)
- Adsorption of phosphate (1)
- Adult insects (1)
- Aging mechanism (1)
- Amorphous-alloys (1)
- Analyse non-destructive (1)
- Analysis of fiber material (1)
- Ancient gold (1)
- Areal density (1)
- Articular cartilage (1)
- Bauplan (1)
- Behavior (1)
- Bioceramics (1)
- Bioregenerative ceramics (1)
- Brazil (1)
- Brennstoffzellen (1)
- CO adsoprtion (1)
- CO adsorption (1)
- CT (1)
- Carbon dioxide evolution (1)
- Carbon-dioxide (1)
- Cartilage (1)
- Cartilage islands (1)
- Catalysis (1)
- Cells (1)
- Certified reference material (1)
- Chondrocyte (1)
- Chromium (1)
- Coherence (1)
- Color X-ray camera (1)
- Computed Tomography (1)
- Copper alloys (1)
- Coprecipitation (1)
- Cortical bone (1)
- Cortical bone structure (1)
- Cr (1)
- Crack formation (1)
- Cross section (1)
- Cyclic voltammetry (1)
- Córrego Bom Sucesso (1)
- DMFC (1)
- Data matching (1)
- Deformation (1)
- Degradation (1)
- Dentistry (1)
- Dessins à pointe d´argent (1)
- Detector calibration (1)
- Digital X-ray detector (1)
- Direct methanol fuel cell (1)
- Direct methanol fuel cells (1)
- Dispersion (1)
- Disque déleste de Nebra (1)
- Divergent XAFS (1)
- Double-Crystal-Monochromator with sagittal bender (1)
- Double-Multilayer-Monochromator with meridional bender (1)
- EDXRF (1)
- Edge tomography (1)
- Electrochromic device (1)
- Electron-irradiation (1)
- Elemental analysis (1)
- Elemental imaging (1)
- Emeralds (1)
- Endochondral bone (1)
- Estrogen (1)
- FIB/SEM imaging (1)
- Fast X-ray imaging (1)
- Ferrofluid (1)
- Final Gravettian (1)
- Fingerprinting (1)
- Fluorescence à rayons X (1)
- Fly-ash (1)
- Fourier optics (1)
- Frustration (1)
- Full-field X-ray fluorescence (1)
- Gas diffusion layer (1)
- Gas diffusion layer (GDL) (1)
- Gas diffusion layer (GDL) materials (1)
- Gas diffusion layers (1)
- Gas-diffusion layers (1)
- Geoscience (1)
- Glas (1)
- Glass structure (1)
- Glass-forming ability (1)
- Gold Synchrotron XRF (1)
- Gravettien final (1)
- HR-TEM (1)
- HT-PEFC (1)
- Hiddensee treasure (1)
- High energy resolution (1)
- High quantum efficiency (1)
- High resolution Sy-CT (1)
- Himmelsscheibe von Nebra (1)
- Hydrogen depth profiling (1)
- ICP-IDMS (1)
- INAA (1)
- Imaging (1)
- In situ study (1)
- Indische Moghulmalereien (1)
- Instrumentation for neutron sources (1)
- Iron oxide spectra (1)
- Isotope ratio (1)
- Ivoire de mammouth (1)
- Jan van Eyck (1)
- K-edge (1)
- L3-edge (1)
- LSW (1)
- Lacunae (1)
- Lamellar bone (1)
- Limit of detection (1)
- Linear energy transfer (1)
- Liquid water (1)
- Liquid water flow rate (1)
- Lodine (1)
- Long-range microscope (1)
- Macrophagen (1)
- Maia detector (1)
- Mammoth ivory (1)
- Material analysis (1)
- Materialcharakterisierung (1)
- Mechanical properties (1)
- Membrane electrode assembly (1)
- Membrane electrode assembly (MEA) (1)
- Metal elements (1)
- Metal foams (1)
- Metal matrix composites (1)
- Metal point (1)
- Metallic glasses (1)
- Metallnanocluster (1)
- Metals (1)
- Methanol (1)
- Micro analysis (1)
- Micro-XAS (1)
- Micro-tomography (1)
- MicroCT (1)
- MicroPIXE (1)
- Microbeam (1)
- Microporous layer (1)
- Microporous layer (MPL) (1)
- Microstructure in human Teeth (1)
- Minas Gerais (1)
- Modelling (1)
- Monochromatic excitation (1)
- Monte Carlo (1)
- Monte-Carlo simulation (1)
- Multi-component alloy (1)
- Multilayer mirrors (1)
- Nanoalloys (1)
- Nanocapillary (1)
- Nanoparticle formation (1)
- Nebra sky disc (1)
- Neutron detectors (cold, thermal, fast neutrons) (1)
- Neutron imaging technique (1)
- Neutron radiography (1)
- Nodular cast iron (1)
- Non-destructive testing (1)
- Nuclear industry (1)
- Nuclear medicine (1)
- Nuclear reaction analysis (1)
- Optische Eigenschaften (1)
- Or (1)
- Ovariectomy (1)
- Oxidation (1)
- PAA (1)
- PEM Fuel-cells (1)
- PEMFC (1)
- PIGE (1)
- PIXE (1)
- PIXE-XRF (1)
- PLS (1)
- Palladium (1)
- Partial coherence in imaging (1)
- Perforated gas diffusion layer (GDL) (1)
- Peri-implantitis (1)
- Perles rectangulaires (1)
- Phase modulation (1)
- Phase-contrast microscopy (1)
- Phosphoric acid (1)
- Platinum Wavelength dispersive D2XRF (1)
- Polarisation (1)
- Polycapillary optic (1)
- Polycapillary optics (1)
- Polycapillary structure (1)
- Polymer electrolyte membrane fuel cell (1)
- Porosity (1)
- Positron lifetime (1)
- Provenancing (1)
- Pt (1)
- Pt-Pd nuggets (1)
- PtRu corrosion (1)
- RBS (1)
- Rat (1)
- Re-XANES (1)
- Rectangular beads (1)
- Reduction (1)
- Reflectometry (1)
- Renaissance (1)
- Rock porosity (1)
- Ruthenium distribution (1)
- Röntgenfluoreszenzanalyse (RFA) (1)
- SR-XRF (1)
- SR-XRF analysis (1)
- SY-RFA (1)
- SY-XRF (1)
- Sample changer (1)
- Scanning SAXS (1)
- Scanning WAXS (1)
- Scanning electron microscopy (1)
- Sediments (1)
- Shear bands (1)
- Silberstiftzeichnungen (1)
- Silica (1)
- Silicon drift detector (1)
- Silicon impurities (1)
- Silver point drawings (1)
- Silverpoint (1)
- Small-angle X-ray scattering (1)
- Solar cell (1)
- Spatial resolution (1)
- Specifikation (1)
- State (1)
- Stopping cross section (1)
- Strain analysis (1)
- String metal support interaction (1)
- Strong metal support interaction (1)
- Structural model (1)
- Styrene butadiene rubber (1)
- Surface analysis (1)
- Sy-XRF (1)
- Sy-XRF analysis (1)
- Synchrotron X-ray (1)
- Synchrotron X-ray tomography (1)
- Synchrotron based microtomography (1)
- Synchrotron micro-computed tomography (1)
- Synchrotron radiation X-ray fluorescence (1)
- Synchrotron radiation-based µCT (1)
- Synchrotron tomography (1)
- Synchrotron x-ray radiography (1)
- Synchrotronstrahlung (1)
- TXRF (1)
- TXRF-XANES (1)
- Technical binary alloys (1)
- Temperature (1)
- Thermal stability (1)
- Three-dimensional imaging (1)
- Through-plane (1)
- Titanium (1)
- Trace elements (1)
- Trace-elements (1)
- Transformation (1)
- Trésor d´Hiddensee (1)
- Two-phase flow (1)
- VHCF (very high cycle fatigue) (1)
- Vanadium oxide (1)
- Visualization (1)
- WDXRF (1)
- Water distribution (1)
- Water transport paths (1)
- Wave properties (1)
- White beam topography (1)
- X-ray CCD camera (1)
- X-ray Computed Tomography (1)
- X-ray absorption spectra (1)
- X-ray diffraction (1)
- X-ray energy edge (1)
- X-ray fluorescence analysis (1)
- X-ray micro beam (1)
- X-ray monochromators (1)
- X-ray scattering (1)
- X-ray spectroscopy (1)
- X-ray synchrotron radiography (1)
- X-ray tomography (1)
- X-ray-diffraction (1)
- X-rays (1)
- XRR (1)
- Xanes (1)
- Zerstörungsfrei (1)
- Zerstörungsfreie Analyse (1)
- Zn-Fe-Zr nanoparticles (1)
- gold (1)
- µ-SRXRF (1)
- µCT (1)
Organisationseinheit der BAM
- 6 Materialchemie (3)
- 6.3 Strukturanalytik (3)
Eingeladener Vortrag
- nein (3)
With the aim of improving limits of detection (LOD) of trace elements in a matrix with adjacent fluorescence energies, a simple double dispersive X-ray fluorescence detection system (D2XRF) was constructed to operate at the beamlines BAMline and the mySpot @ BESSY II. This system is based on the combination of a crystal analyzer with an energy resolving single photon counting pnCCD. Without further collimators, the efficient suppression of the background by the pnCCD and the good energy resolution of the crystal results in improved LOD. In first order reflections, an energy resolution of 13 eV for Cu Kα was reached, and an energy range of 1 keV was covered in one shot.
This new system was applied to the detection of platinum (Pt) in gold leaves with a LOD of 0.9 mg/kg, which is the lowest attained by totally non-destructive methods nowadays. The presence of Pt in gilded objects from Abydos and Byzantine mosaics provides vital information, as it indicates the alluvial origin of the gold for these examples.
Partial least squares (PLS) regression-based methods have been proven to be a good alternative for quantification in X-ray fluorescence spectroscopy. These methods are fast and easy to use though giving satisfactory results under certain conditions. One of these conditions is the necessity of having a great number of spectra to build the model (training set). The choice of the constituent concentration range in the training set has a big influence on the accuracy of the model. Better accuracy is obtained if the model is built in relatively narrow regions containing (or close to) the real concentration value.
In the present work, Monte Carlo (MC) simulated spectra are used to form the training set. The advantage to use MC generated training spectra is the unlimited availability of perfect standards.
This paper aims to improve the accuracy of the method by introducing a multiple step procedure in order to build the PLS model using narrow concentration range close to (or containing) the real concentration values in the samples to be measured.
This approach consists of an initial guess of the constituents' concentrations and a preliminary PLS model before building the final model. The prediction of ten MC simulated alloy standard samples containing Ti, Mn, Fe, Co, Cu, Zn, Sr, Zr, and Mo using this method allowed to have average relative prediction errors less than 5% for elements with narrow concentration ranges.