Filtern
Erscheinungsjahr
- 2012 (9) (entfernen)
Dokumenttyp
Sprache
- Englisch (9)
Referierte Publikation
- ja (9)
Schlagworte
- Compound refractive lens (2)
- Water transport (2)
- Articular cartilage (1)
- Coprecipitation (1)
- Data matching (1)
- Dispersion (1)
- EXAFS (1)
- FIB/SEM imaging (1)
- Ferrofluid (1)
- Gas diffusion layers (1)
Hydrogen analysis is of particular importance in thin film technology and it is often necessary to obtain a depth profile. The method with the best depth resolution is NRA using the 6385 keV resonance of the 1H(15N,αγ)12C nuclear reaction. The correct quantification of the depth and concentration scales in the measured hydrogen profiles relies on accurate stopping power values. We present a method to deduce these values from a combination of two techniques: NRA and X-ray reflectometry (XRR). This method is applied to the determination of the stopping power of ~6.4 MeV 15N ions in H-containing amorphous Si-layers (a-Si:H). Density-independent stopping powers at different H concentrations are determined by combining the results from NRA and XRR with an overall uncertainty of 3.3%, showing good agreement with SRIM values. This work shows exemplary the methodology for future evaluation of stopping powers for quality assurance in NRA.
Agglomerated superparamagnetic iron
oxide nanoparticles can easily and in large scale be
precipitated from iron salt solutions. Although the
process is well known, it is ambiguously either assumed
that magnetite or maghemite is obtained. The first part
of our study clarifies this question using X-ray absorption
spectroscopy. For further processing of the nanoparticles,
i.e., for giving them a surface functionality or
incorporating them into composites, it is important to
break the agglomerates and individualize the particles
at first. This can effectively be done with nitric acid
treatment. The influence of this process on the particles
chemistry and structure was analyzed in great detail
using X-ray diffraction, X-ray absorption, and smallangle
X-ray scattering. In contrast to our expectation,
no oxidation from magnetite (Fe3O4) to maghemite (γ-
Fe2O3) was found; the formal valence of the particles in
any case is magnetite (Fe3O4). Instead, an increase in
the particles' surface disorder was discovered from
X-ray absorption analyses and high-resolution transmission
electron microscopy. The acid treatment
roughens and distorts the surface of the nanoparticles
which is connected with an increased spin disorder.
Synchrotron X-ray radiography and tomography investigations of a custom-made polymer electrolyte membrane fuel cell optimised for visualisation purposes are presented. The 3D water distribution and transport pathways in the porous carbon fibre gas diffusion layers (GDLs) were investigated. The authors found that water is not only moving from the GDL into the channel, but can also take the opposite way, that is, from the channel into free pore space of the GDL. Such movement of water into the opposite direction has been subject of speculations but has so far not yet been reported and might bring new insights into the general water transport behaviour, which might give new aspects to the general description of water transport processes and influence modelling assumptions to describe the process taking place in the GDL.
A study regarding the possibility to use compound refractive lenses (CRLs) for X-ray absorption spectroscopy (XAS) was conducted. For XAS measurements the energy of the monochromatic incident beam has to be tuned over an energy range which is broader than the energy bandwidth of a CRL. To prove that µ-XAS with compound refractive lenses is possible, it had to be investigated how changes in the energy influence the beam parameters. This was done by tuning the energy around the nominal energy of the lens and recording images with a high resolution X-ray imaging setup. To investigate the changes in the spot size the scintillator was placed at the nominal focal distance and scans along the beam axis were performed. The effect on the photon flux of the incident beam due to absorption in the lens was investigated by performing XANES measurement on different reference materials with and without CRL. The results of these measurements using a CRL designed for 9 keV are shown and discussed.
We report on the trace analysis of copper and iron impurities in multicrystalline silicon wafers with the microbeam X-ray fluorescence (µ-XRF) technique. The efficiency of solar cells, which are based on multicrystalline silicon wafers, is strongly influenced by minor contamination with metals such as copper and iron. Application of compound refractive lenses (CRLs) in µ-XRF allows versatile two-dimensional mapping of relevant contaminations and localization of their sites of deposition. In this context, the measured bulk average limit of detection (LOD) was one picogram of iron and copper per gram of silicon. We suggest that µ-XRF is a valuable tool for non-destructive spatial (3D) quantification of metal impurities in a wide range of materials and devices whose functioning could be critically affected by impurities.
By means of synchrotron X-ray computed tomography, model composites consisting of silica and styrenebutadiene rubber were studied with a very high spatial resolution. By our analysis technique we were able to determine the nano- and micro dispersion from the experimental results by our numerical analysis. These results are discussed with respect to crucial advantages of the generically 3-dimensional tomography technique as compared to 2-dimensional methods. Our quantitative analysis of the 3d images demonstrates that in the case of our model composites the filler dispersion is good, independent on the filler concentration. Our new 3-dimensional results evidence that considering only 2-d pictures may lead to ambiguities that can lead to wrong conclusions.
A new high-resolution detector setup for neutron imaging has been developed based on infinity-corrected optics with high light collection, combined with customized mounting hardware. The system can easily be installed, handled and fitted to any existing facility, avoiding the necessity of complex optical systems or further improved electronics (CCD). This is the first time optical magnification higher than 1:1 has been used with scintillator-based neutron detectors, as well as the first implementation of infinity corrected optics for neutron imaging, achieving the smallest yet reported effective pixel size of 3.375 µm. A novel transparent crystal scintillator (GGG crystal) has been implemented with neutrons for the first time to overcome limitations of traditional powder scintillators (Li6/ZnS, Gadox). The standardized procedure for resolution measurements with the Modulation Transfer Function (MTF) is summarized to facilitate comparison between instruments and facilities. Using this new detector setup, a resolution of 14.8 µm with a field of view of 6 mm × 6 mm has been achieved while maintaining reasonable count times. These advances open a wide range of new possible research applications and allow the potential for additional future developments.
Perforated gas diffusion layers (GDLs) of polymer electrolyte membrane fuel cells (PEMFCs) were investigated by means of in-situ synchrotron X-ray radiography during operation. We found a strong influence of perforations on the water distribution and transport in the investigated Toray TGP-H-090 GDL. The water occurs mainly around the perforations, while the holes themselves show varying water distributions. Some remain dry, while most of them fill up with liquid water after a certain period or might serve as drainage volume for effective water transport.
The study was aimed at demonstrating a true cellular resolution for articular cartilage using synchrotron radiation-based X-ray microcomputed tomography (SR-µCT) with a sample-specific optimization of the phase contrast. The generated tomographic data were later used to prepare a matching histological sample from the full volume specimen.
We used highly coherent and monochromatic X-rays from a synchrotron source to image a tissue sample of bovine articular cartilage after deparaffinization. Phase contrast enhancement was achieved by using five different sample to detector distances for the same X-ray energy. After tomography, the sample was re-embedded into resin while retaining a dedicated sample orientation for subsequent sectioning and polishing, which was conducted until a previously defined spatial position was achieved. The protocol for resin embedding was developed to inhibit morphological changes during embedding. Giemsa staining was applied for better structural and morphological discrimination. Data from tomography and lightmicroscopy were exactly matched and finally compared to results from FIB/SEM imaging. Image detail was achieved at a single cell resolution. Image detail was achieved at a single cell resolution, which has been estimated to be 0.833 µm/voxel in the tomographic data.
SR-µCT with optimized phase contrast properties represents a method to investigate biological tissues in certain areas of interest, where true cellular resolution or enhanced volumetric imaging is needed. In this study, we demonstrate that this method can compete with conventional histology using light microscopy but even surpasses it due to the possibility of retrieving volumetric data.