Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (89)
- Sonstiges (21)
- Beitrag zu einem Sammelband (11)
- Posterpräsentation (9)
- Beitrag zu einem Tagungsband (8)
- Vortrag (3)
- Forschungsbericht (1)
Schlagworte
- Synchrotron radiation (13)
- XRF (10)
- Synchrotron (8)
- XANES (7)
- BAMline (6)
- EXAFS (6)
- Gold (6)
- Radiography (6)
- Water transport (6)
- X-ray imaging (6)
Organisationseinheit der BAM
- 6 Materialchemie (3)
- 6.3 Strukturanalytik (3)
Eingeladener Vortrag
- nein (3)
Pilot studies have been carried out at the BAMline at BESSY II in collaboration with the Bundesanstalt
für Materialforschung und -prüfung (BAM) on metal- and metalloid-containing compounds in biological
samples after electrophoretic protein separation. After sodium dodecylsulfate polyacrylamide gel
electrophoresis (SDS-PAGE) and transfer onto a blotting membrane the distribution of selenium among
the proteins of testis homogenate of a rat and a wallaby was determined. The comparison with the
autoradiogram of 75Se-labeled proteins separated in the same way showed that of nine seleniumcontaining
proteins found in rat testis homogenate by autoradiography four could be detected by
synchrotron radiation X-ray fluorescence analysis (SRXRF).
Strahlenverfahren in Kombination - ein Werkzeug für Analyse und Zertifizierung von Feststoffen
(2002)
Orientierende Versuche zur Schwefelbestimmung in Kraftstoffen haben gezeigt, dass die Röntgenbeamline der BAM bei BESSY II geeignet ist, Schwefel auch in kleinen Konzentrationen zu bestimmen. Da das Verfahren der synchrotronstrahlungsinduzierten Röntgenfluoreszenzanalyse (SYRFA) für den Vor-Ort-Einsatz nicht geeignet ist, ist das Ziel der Untersuchungen, durch Variation von Anregungsenergie und -geometrie mögliche Quellen für systematische Fehler zu untersuchen. Durch geeignete Korrekturfaktoren kann dann die Richtigkeit der Analyseergebnisse gewährleistet werden. Das Verfahren soll dann als Alternative bzw. Ergänzung zu zerstörenden Verfahren der Schwefelanalyse Anwendung finden. Damit wird ein Beitrag zur künftigen Herstellung zertifizierter Referenzmaterialien (ZRM) geleistet.
The first hard X-ray beamline at BESSY II will be installed by BAM and PTB at a superconducting 7 T wavelength shifter. The main optical elements of the beamline are a Double-Multilayer-Monochromator and a Double-Crystal-Monochromator. The two devices can be used separately or in-line. Main applications of monochromatic radiation with photon energies up to 50 keV are X-ray fluorescence analysis, micro-computed tomography, X-ray topography, detector calibration and reflectometry. Calculable undispersed radiation up to 200 keV will be available for radiometric applications.
The first hard x-ray beamline at BESSY II has been installed by BAM and PTB at a superconducting 7 T wavelength shifter. The main optical elements of the beamline are a double-multilayer monochromator and a double-crystal monochromator. Depending on the application, the two devices are used separately or in-line. The main applications of the monochromatic radiation with photon energies up to 60 keV are x-ray fluorescence analysis, micro computed tomography, x-ray topography, detector calibration and reflectometry. Calculable undispersed radiation up to 200 keV is available for radiometric applications.
New analyses of a series of very rare silverpoint drawings that were executed by Rembrandt Harmensz. van Rijn (16061669) which are kept today in the Kupferstichkabinett (Museum of Prints and Drawings) of the State Museums of Berlin are reported here. Analysis of these drawings requires particular attention because the study has to be fully non-destructive and extremely sensitive. The metal alloy on the paper does not exceed some hundreds of µg/cm². Therefore, synchrotron radiation induced X-ray fluorescence (SR-XRF) is together with external micro-proton-induced X-ray emission the only well-suited method for the analyses of metalpoint drawings. In some primary work, about 25 German and Flemish metalpoint drawings were investigated using spatially resolved SR-XRF analysis at the BAMline at BESSY. This study enlarges the existing FrenchGerman database of metalpoint drawings dating from the 15th and 16th centuries, as these Rembrandt drawings originate from the 17th century where this graphical technique was even rarer and already obsolete. It also illustrates how SR-XRF analysis can reinforce art historical assumptions on the dating of drawings and their connection.
Recent methods of phase imaging in x-ray tomography allow the visualization of features that are not resolved in conventional absorption microtomography. Of these, the relatively simple setup needed to produce Fresnel-propagated tomograms appears to be well suited to probe tooth-dentin where composition as well as microstructure vary in a graded manner. By adapting analytical propagation approximations we provide predictions of the form of the interference patterns in the 3D images, which we compare to numerical simulations as well as data obtained from measurements of water immersed samples. Our observations reveal details of the tubular structure of dentin, and may be evaluated similarly to conventional absorption tomograms. We believe this exemplifies the power of Fresnel-propagated imaging as a form of 3D microscopy, well suited to quantify gradual microstructural-variations in teeth and similar tissues.
A layer of Sb atoms, implanted with an energy of 400 keV and a nominal dose of 5×1016 atoms/cm2 into a high purity silicon wafer, was certified for its areal density (atoms/cm2) using Rutherford backscattering spectrometry (RBS), instrumental neutron activation analysis (INAA) and inductively coupled plasma isotope dilution mass spectrometry (ICP-IDMS) and for its isotope ratio using INAA and ICP-IDMS. Excellent agreement between the results of the different independent methods was found. In the present work, the measurements of the homogeneity of the areal density of Sb, previously determined with RBS in spots having 1 mm diameter, are improved with synchrotron X-ray fluorescence analysis: Higher precision in even smaller sample spots allows to estimate a reduced inhomogeneity of the whole batch of samples of the order of only 0.4%. Thus the uncertainty of the certified value can further be reduced. Down to fractions of a chip with 0.3×0.4 mm2 area, the areal density is now certified as (4.81±0.06)×1016 Sb atoms/cm2, where the expanded uncertainty 0.06 (coverage factor k=2) corresponds to only 1.2%. The relative merits of the different analytical methods are discussed.
Rock porosity determination by combination of X-ray computerized tomography with mercury porosimetry
(1997)
Abstract First results are described of coupling of mercury porosimetry with X-ray computerized tomography (CT) as a new combination technique for rock porosity studies. This technique is suitable for rock samples with a pronounced mercury intrusion-extrusion hysteresis and includes CT measurements before and after mercury intrusion. The entrapped portion of mercury, when the pressure after the intrusion into the rock sample is reduced to 0.1 MPa, serves as a contrast agent in the porous network to localize spatial distribution of rock porosity by CT. The results obtained show that the mercury intrusion and therefore the porosity were quite different for the separate mineral phases. Therefore the combination of mercury porosimetry and computer tomography can give 3-D data on mineral-specific porosity distributions with additional pore size information. In contrast to mercury porosimetry as a single method, results of the combination technique with CT represent a direct visualization of porosity variation and do not depend on any special pore network model.
A new method for the physical characterization of rock matrices for use in site investigations of nuclear waste repositories has been developed. The method can provide information needed in the assessment of the performance of the geosphere working as a natural barrier retarding the migration of radionuclides by diffusion into the rock matrix. Most conventional methods for the physical characterization of rocks give only bulk information. The combination of mercury porosimetry and computer tomography can give 3-D data on mineral-specific porosity distributions with additional pore size information. Additionally, limits for mineral-specific internal surface areas can be estimated, which is essential for the assessment of water-rock interaction and reactive interaction with radionuclides (sorption). Results of measurements on granitic rock (granodiorite) from the Baltic shield are discussed and integrated with results by complementary methods.
The impact of very high cycle fatigue (VHCF) load conditions on the microstructure of specimens consisting of nodular cast iron is analyzed by means of micro-computed tomography (µCT) utilizing both monochromatic synchrotron radiation and polychromatic X-ray tube radiation. Using 3D µCT, the microstructure in the region of the smallest cross-sections of shouldered round specimens is imaged in different stages of the VHCF loading. By digital image correlation (DIC) of these tomograms strain fields are analyzed three-dimensionally. Strain levels in the range of a few percent were detected. It is proven that a localization of strain allows to predict the site of the crack which precedes and induces the macroscopic failure of the specimens.
Hydrogen analysis is of particular importance in thin film technology and it is often necessary to obtain a depth profile. The method with the best depth resolution is NRA using the 6385 keV resonance of the 1H(15N,αγ)12C nuclear reaction. The correct quantification of the depth and concentration scales in the measured hydrogen profiles relies on accurate stopping power values. We present a method to deduce these values from a combination of two techniques: NRA and X-ray reflectometry (XRR). This method is applied to the determination of the stopping power of ~6.4 MeV 15N ions in H-containing amorphous Si-layers (a-Si:H). Density-independent stopping powers at different H concentrations are determined by combining the results from NRA and XRR with an overall uncertainty of 3.3%, showing good agreement with SRIM values. This work shows exemplary the methodology for future evaluation of stopping powers for quality assurance in NRA.
Agglomerated superparamagnetic iron
oxide nanoparticles can easily and in large scale be
precipitated from iron salt solutions. Although the
process is well known, it is ambiguously either assumed
that magnetite or maghemite is obtained. The first part
of our study clarifies this question using X-ray absorption
spectroscopy. For further processing of the nanoparticles,
i.e., for giving them a surface functionality or
incorporating them into composites, it is important to
break the agglomerates and individualize the particles
at first. This can effectively be done with nitric acid
treatment. The influence of this process on the particles
chemistry and structure was analyzed in great detail
using X-ray diffraction, X-ray absorption, and smallangle
X-ray scattering. In contrast to our expectation,
no oxidation from magnetite (Fe3O4) to maghemite (γ-
Fe2O3) was found; the formal valence of the particles in
any case is magnetite (Fe3O4). Instead, an increase in
the particles' surface disorder was discovered from
X-ray absorption analyses and high-resolution transmission
electron microscopy. The acid treatment
roughens and distorts the surface of the nanoparticles
which is connected with an increased spin disorder.
Well-defined and facetted bimetallic gold–palladium nanoalloys have been synthesized and anchored in spherical polyelectrolyte brushes (SPB) as composite particles (AuPd@SPB). These particles are better catalysts in aqueous phase than the pure metals. The atomistic arrangement of these nanoalloys has been analysed by extended X-ray absorption fine structure (EXAFS) spectroscopy at the Au–L3 and the Pd–K absorption edge. The samples with high amounts of gold appear as almost statistically mixed random alloys. Alloy compositions with less gold show slight enrichment of Pd at the surface of the particle. In addition, signals of non-metallic palladium appear at the Pd–K edge which indicate the presence of the Pd2+ species in addition to metallic palladium. The relation of these structural features to the catalytic activity is discussed.
We present a new high resolution X-ray imager based on a pnCCD detector and a polycapillary optics. The properties of the pnCCD like high quantum efficiency, high energy resolution and radiation hardness are maintained, while color corrected polycapillary lenses are used to direct the fluorescence photons from every spot on a sample to a corresponding pixel on the detector. The camera is sensitive to photons from 3 to 40 keV with still 30% quantum efficiency at 20 keV. The pnCCD is operated in split frame mode allowing a high frame rate of 400 Hz with an energy resolution of 152 eV for Mn Kα (5.9 keV) at 450 kcps. In single-photon counting mode (SPC), the time, energy and position of every fluorescence photon is recorded for every frame. A dedicated software enables the visualization of the elements distribution in real time without the need of post-processing the data. A description of the key components including detector, X-ray optics and camera is given. First experiments show the capability of the camera to perform fast full-field X-Ray Fluorescence (FF-XRF) for element analysis. The imaging performance with a magnifying optics (3×) has also been successfully tested.