Filtern
Erscheinungsjahr
Dokumenttyp
Schlagworte
- Traceability (4)
- Chemical analysis (3)
- Copper (3)
- Metrology (3)
- Zinc (3)
- Calibration (2)
- Carrier gas hot extraction (2)
- Element determination (2)
- High purity metals (2)
- ITS-90 (2)
Organisationseinheit der BAM
The determination of O, N and H using a microwave induced plasma coupled to carrier gas hot extraction was exploratory investigated. The signal intensities versus time of blanks and calibration materials were recorded. To check for interferences the signal intensities versus wavelength were recorded at the times just before increase and at the maximum of the time dependent analytical signal. O, N and H were investigated at their prominent wavelengths of 777 nm, 174 nm and 486 nm, respectively. Calibration was performed for O, N and H in the ranges of 027 µg, 351000 µg and 343 µg respectively. For concentration values in the middle of the linear part of the investigated calibration interval, a relative precision of 5% at 13 µg, 2% at 74 µg and 0.6% at 23 µg for O, N and H respectively was found. The maximum matrix load to the plasma used was found to be 150 µg min-1. From the signal to noise ratio and the sensitivity obtained, instrumental limits of detection (3s) of 0.01 µg for O, 1 µg for N and 0.1 µg for H were found. Assuming a typical sample mass of 1 g this corresponds to relative LODs of 0.01 µg g-1, 1 µg g-1 and 0.1 µg g-1 for O, N and H respectively.
Mass spectrometric detection can play a prominent role in the assessment of different reactions occurring at varied temperatures in a milled ZnO/Al mixture. This is the first time that online mass spectrometric information was used as a tool for monitoring and understanding the chemical reduction process mechanism. We have observed four different types of reaction taking place: (1) distillation of Zn metal, (2) reduction of ZnO by activated Al, (3) melting of Al and finally (4) reduction of ZnO by inactivated Al. The experimental conditions and results observed by QMS were supported with literature data and physical measurement data from X-Ray Diffraction (XRD) which gave us an idea about the complex reaction cascade which occurred during the formation of the zinc metal.
A complete metrological traceability system for measurement results of chemical analysis was set up. Core components are pure substances (national standards) characterised at the highest metrological level, primary solutions prepared from these pure substances and secondary solutions deduced from the primary solutions and intended for sale. The relative uncertainty of the element mass fraction of the primary substances and solutions is < 0.01 and < 0.05%, respectively. For the certification of transfer solutions and for stability testing, a precision measurement method for element contents has been developed by means of optical emission spectrometry (ICP OES) by which uncertainties between 0.1 and 0.05% can be achieved. The dissemination to field laboratories is effected with the aid of a calibration laboratory of the German Calibration Service (DKD) which certifies the element content of the secondary solutions with an uncertainty <= 0.3%. Calibration with these solutions enables the user to establish traceability of his measurement results to the International System of Units (SI). Currently, the system comprises Cu, Fe, Bi, Ga, Si, Na, K, Sn, W, and Pb.
Special new techniques of atomic spectrometric methods for trace analysis of high purity metals
(2003)
Within the Working Group on Inorganic Analysis (IAWG) of the Consultative Committee for Amount of Substance: Metrology in Chemistry and Biology (CCQM) international key comparisons and pilot studies related to inorganic analysis are carried to ensure consistency in this field at the highest level. Some of these comparisons deal directly with the preparation and characterization of monoelemental solutions or with topics, closely related. The importance of monoelemental solutions lies in the fact that almost every measurement in inorganic analysis relies on the comparison with either a reference material, or references in form of solutions, usually (mono)elemental solutions. All quantitative measurement approaches, e.g. isotope dilution or standard addition, need an accurate reference solution made from a well characterized reference material, prepared under full gravimetric control. These primary (monoelemental) solutions do not only serve as arbitrary references/calibration solutions, but they also link up measurement results to the International System of units (SI), this way establishing the so-called metrological traceability to a measurement unit of the SI. Without such solutions on the highest possible level of accuracy and with the smallest possible associated uncertainties (for e.g. element content and/or impurities), an analysis itself can never be as good as it could be with appropriate reference solutions. This article highlights select key comparisons and pilot studies dealing with monoelemental solution related topics within the IAWG from the foundation of CCQM – 25 years ago – up to latest achievements in the field of inorganic analysis.
Within the National Metrology Institutes (NMIs) and designated laboratories, an interlaboratory comparison, CCQM-P107, was conducted to verify the degree of international comparability concerning the results of purity analysis. The mass fractions of Ag, Bi, Cd, Cr, Ni, Tl at the lower mg/kg-level in a high purity zinc material were determined, but the real measurand in metrological sense was the sum of the six mass fractions. Homogeneity was investigated by glow discharge mass spectrometry, reference values were obtained using isotope dilution mass spectrometry. Six NMIs participated, contributing eight independent data sets. The agreement amongst the results of the participants, their median and the agreement with the reference values were usually excellent and in almost all cases below the target uncertainty of 30% relative. In this manner, the accuracy of results and the comparability between the participants was demonstrated to be established.