Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (26)
Referierte Publikation
- ja (26) (entfernen)
Schlagworte
- Traceability (4)
- Chemical analysis (3)
- Copper (3)
- Zinc (3)
- Calibration (2)
- Carrier gas hot extraction (2)
- Element determination (2)
- High purity metals (2)
- ITS-90 (2)
- Impurities (2)
- Metrology (2)
- Metrology in chemistry (2)
- Primary standards (2)
- Advanced ceramics (1)
- Aluminium alloy (1)
- CCQM-K42 (1)
- CCQM-P107 (1)
- Classical primary measurement method (CPM) (1)
- Comparability (1)
- Doped and pressed metal powder samples (1)
- Elemental analysis (1)
- Elemental calibration solutions (1)
- Elemental determination (1)
- Emission spectroscopy (1)
- Fixed points (1)
- Fixed-points (1)
- GD-MS (1)
- GD-OES (1)
- Glow discharge (1)
- Glow discharge mass spectrometry (GD-MS) (1)
- Grimm type glow discharge (1)
- Grimm-type cell (1)
- HR ICP-MS (1)
- High resolution glow discharge mass (1)
- High-purity copper (1)
- High-purity iron (1)
- Hollow cathode (1)
- ICP-MS (1)
- Inorganic chemical analysis (1)
- Inter laboratory comparison (1)
- Interlaboratory comparison (1)
- International comparison (1)
- Key comparison (1)
- LA-ICP-MS (1)
- LA-ICP-OES (1)
- Laser ablation (1)
- Magnesium (1)
- Metal (1)
- Metrological traceability (1)
- Micro-hardness (1)
- Microwave induced plasma spectrometry (1)
- Nitrogen determination (1)
- Non-metal determination (1)
- Oxygen determination (1)
- Phase diagrams (1)
- Photon activation analysis (1)
- Pin sample (1)
- Precision measurement of elements (1)
- Primary difference measurement method (PDM) (1)
- Primary standard (1)
- Primary transfer standards (PTSs) (1)
- Pure metals (1)
- Pure substances (1)
- Purification (1)
- Purity (1)
- Purity analysis (1)
- Purity assessment (1)
- SS ET AAS (1)
- Sensitivity (1)
- Silver (1)
- Spark-OES (1)
- Spectrometry (1)
- Thermal effects (1)
- Total purity (1)
- Ultra high purity (1)
- Uncertainty (1)
- Vacuum distillation (1)
Organisationseinheit der BAM
Detection and monitoring of volatile elements released during the preparation of ultra high purity zinc by vacuum distillation (VD) is reported using online quadrupole gas source mass spectrometry (QMS). The theoretically calculated vapour pressures (pv) for the volatile impurity elements using Dushman constants and the practically observed mass spectra were found to be consistent (S. Dushman and J. M. Lafferty, Scienific Foundations of Vacuum Technique, 2nd ed., Wiley, New York, 1962). This is the first time that the potential ability of an online mass spectrometer was used for monitoring and understanding the process mechanism during the purification of metals (Zn) using VD. We here also illustrate our findings with the results from high resolution glow discharge mass spectrometer (HR-GDMS) analysis before and after the purification of Zn.
Mass spectrometric detection can play a prominent role in the assessment of different reactions occurring at varied temperatures in a milled ZnO/Al mixture. This is the first time that online mass spectrometric information was used as a tool for monitoring and understanding the chemical reduction process mechanism. We have observed four different types of reaction taking place: (1) distillation of Zn metal, (2) reduction of ZnO by activated Al, (3) melting of Al and finally (4) reduction of ZnO by inactivated Al. The experimental conditions and results observed by QMS were supported with literature data and physical measurement data from X-Ray Diffraction (XRD) which gave us an idea about the complex reaction cascade which occurred during the formation of the zinc metal.
Ultra high purity Zn (m6N5) was obtained through triple vacuum distillation using an m4N5 Zn as input material. High-volatile impurities were removed from the zinc matrix by vacuum evaporation, while traces having lower volatility than the matrix remained in the residual material after finishing of the entire purification process. The time required for the removal of the main high-volatile impurity (Cd) was monitored using a connected gas source mass spectrometer. During distillation the Zn vapor of the distillate was condensed on the cap of a glassy carbon crucible which was water cooled by a movable copper block. The temperatures were optimized for the removal of the volatiles and for the distillation process using vapor pressure data. High resolution glow discharge mass spectrometry was applied for the analysis and purity evaluation of the distilled and input zinc. The analysis confirmed the reduction of the metallic impurities from 43 mg kg-1 to 0.5 mg kg-1 (m6N5) after three consecutive vacuum distillations. An increase in the grain size and a decrease in the micro-hardness were observed for the purified Zn material.
The hollow cathode (HC) effect was investigated in non-cooled 15 mm deep drilled flat metallic analytical samples that were easy to prepare. The deep cavity used ("complete HC" in contrast to "recessed HC" with 2-3 mm deep cavity) intensified the HC effect notably and therefore distinctly improved the detection power of the common GD-OES with planar cathodes. A signal enhancement of up to a factor of 150, not reported earlier, in comparison with flat conventional samples was achieved. A better separation of the analytical lines from spectral interferences was observed when the HC assembly was applied. Additionally, an effect of strongly enhanced intensities of atomic lines and somewhat decreased intensities of ionic lines was detected in the case of HC in comparison to usual planar cathodes. The investigations were carried out with samples of copper, steel and zinc matrices using both the same and individually optimised glow discharge (GD) electrical parameters.
Synthetic pressed metal powder standards doped with standard solutions were used for the calibration of both commercially available high resolution GD-MS instruments Element GD and VG 9000 for zinc matrix. Different quantification procedures (IBR, Standard RSF, matrix matched RSF from the calibration with CRMs and use of doped synthetic standards) are compared using zinc matrix as an example, whereas the calibration with doped pellets turned out to be the best quantification technique for high-purity materials. The applicability of the Standard RSF concept is scrutinised. In this context, RSF values for several Matrices (Co, Cu, Fe, In and Zn) are reported additionally.
Calibration of two commercially available glow discharge double focusing mass spectrometers, the VG 9000 and Element GD, is described using synthetic pin standards pressed from solution doped copper and zinc matrices. A special pressing die was developed for this purpose and optimal results were obtained with the highest possible pressures, i.e., 95 kN·cm- 2. This calibration approach permits the determination of trace element mass fractions down to µg·kg- 1 with small uncertainties and additionally provides traceability of the GD-MS results in the most direct manner to the SI (International System of Units). Results were validated by concurrent measurements of a number of compact copper and zinc certified reference materials. The impact of the sample pin cross-section (circular or square) was investigated with the use of a new pin-sample holder system for the Element GD. The pin-sample holder was designed by the manufacturer for pin-samples having circular cross-section; however, samples with square pin cross-section were also shown to provide acceptable results. Relative Sensitivity Factors for some 50 analytes in copper (VG 9000, Element GD) and zinc matrices (VG 9000) are presented. The field of applicability of GD-MS may be considerably extended via analysis of pin geometry samples based on their ease of preparation, especially with respect to the accuracy and traceability of the results and the enhanced number of analytes which can be reliably calibrated using such samples.
ICP-MS analysis of high purity molybdenum used as SI-traceable standard of high metrological quality
(2005)
The need, concept and technical approach for the certification of SI-traceable standards of high metrological quality for chemical analysis of the elements is briefly explained. As an example of problems occurring in the certification of these standards, special technical aspects related to the analysis of high purity Mo by ICP-MS, namely blank reduction for Na, Li and Ni by protective coating of the cones with silicon, as well as dealing with the interferences from the Mo matrix, are discussed.
The determination of O, N and H using a microwave induced plasma coupled to carrier gas hot extraction was exploratory investigated. The signal intensities versus time of blanks and calibration materials were recorded. To check for interferences the signal intensities versus wavelength were recorded at the times just before increase and at the maximum of the time dependent analytical signal. O, N and H were investigated at their prominent wavelengths of 777 nm, 174 nm and 486 nm, respectively. Calibration was performed for O, N and H in the ranges of 027 µg, 351000 µg and 343 µg respectively. For concentration values in the middle of the linear part of the investigated calibration interval, a relative precision of 5% at 13 µg, 2% at 74 µg and 0.6% at 23 µg for O, N and H respectively was found. The maximum matrix load to the plasma used was found to be 150 µg min-1. From the signal to noise ratio and the sensitivity obtained, instrumental limits of detection (3s) of 0.01 µg for O, 1 µg for N and 0.1 µg for H were found. Assuming a typical sample mass of 1 g this corresponds to relative LODs of 0.01 µg g-1, 1 µg g-1 and 0.1 µg g-1 for O, N and H respectively.
The special importance of the analysis of non-metals in high purity metals, which will serve as national standards for elemental analysis in Germany, is illustrated for oxygen and nitrogen. The typical range of the mass fraction of oxygen and nitrogen in these materials is below 10.MU.g/g, often close to 1.MU.g/g. The two methods applied at BAM for these measurements are classical carrier gas hot extraction (HE) and carrier gas hot extraction after activation with photons (PAA-HE). The approach, the methods and their advantages and limitations are discussed. Comparative results from the measurement of oxygen and nitrogen in Cu, Fe, Ga, Pb, Sn and W are presented. (author abst.)