While developing a standard for the determination of safety characteristics for hybrid mixtures the authors discovered, that, beside the ignition source, the mixing procedure is the main difference between the single-phase standards for dusts and gases. The preparation of hybrid mixtures containing a flammable gas and a flammable dust in the 20 L-sphere can be realized in different ways. Either the flammable gas is filled only in the sphere or only in the dust container or in both. In previous works, almost always the first method is applied, without giving any information on the accuracy of the gas mixtures. In this work the accuracy of the gas mixtures and the results of the tests applying two methods of mixing were studied. No significant influence of the mixing method itself on the safety characteristics explosion pressure pex and the normalized rate of pressure rise (K-value) was found. Obviously, homogenization of the gas mixtures can be obtained sufficiently by the turbulence that is caused during the injection from the dust container into the explosion chamber within a short time. However, the mixing procedure has a great influence on the accuracy of the gas amount of the mixtures obtained. Without modifying the 20 L-sphere by installing precise pressure sensors, assuring its tightness and performing gas analysis, it must be expected, that the accuracy of the gas mixtures is very low. This has a significant influence on the measured safety characteristics and may lead to unsafe facilities or unnecessary expensive safety measures.
The maximum rate of pressure rise (dp/dt)𝑚𝑎𝑥 and the corresponding K-value of hybrid mixtures containing flammable gases and dusts are important for constructive explosion protection measures. Since the safety characteristics of dusts and gases are determined under different conditions, there has been considerable confusion about the influence of flammable gas on the (dp/dt) of dusts and vice versa. While some investigations showed comparably higher values for hybrid mixtures, others stated that the highest value for the gas component alone is the worst case.
The first part of this paper focuses on the confusion around the different statements about (dp/dt)𝑚𝑎𝑥 of hybrid mixtures and where they come from. In the second part of this paper experimental results are presented that illustrate how to clarify the different findings of past research and show what to expect as a real worst-case-value for hybrid mixtures.