In this work, results of numerical simulations and experimental investigations of the mass flow from evaporating liquid pools are presented. Numerical simulations are based on the boundary layer equations combined with an algebraic turbulence model. The experiments were carried out on open air test sites within flat and very rough topographies, at different temperatures with ethanol and cyclohexane as the evaporating liquids. An experimental investigation of the influence of the topography on the evaporation of a liquid pool is conducted. The results of the simulation are validated against experimental data from the open air experiments. Furthermore, a comparison of the simulation results with empirical prediction models has been made.
The Jack Rabbit II (JR II) chlorine field trials in 2015 and 2016 involved nine 5–20 ton releases of pressurized liquefied chlorine from a tank mounted 1 m above a broad flat desert sand surface. A model comparison study was initiated, where 17 widely-used dense-gas dispersion models were run by scientists in seven countries.
Predictions were submitted following specified formats, using specified emissions and meteorology inputs. To compare with the model predictions, sets of observations were defined for the arc-maximum 1–3 s averaged concentrations (arc max C) and for cloud widths and heights (to 20 ppm and 200 ppm contours) at distances from 0.2 to 11.0 km from the release. The initial focus is on the three field trials (1, 6, and 7) that have the highest observed concentrations and that have detailed emissions information. It is found that these models are able to satisfactorily simulate (generally within a factor of two) the observed arc max C’s and their variation with downwind distance at this flat desert site. At each downwind distance, the scatter in the arc max C predictions covers about 1 ½ orders of magnitude, but the observed arc max C is within the range of the predictions. The median of the cloud width predictions is about 50% larger than the observed value for the three trials. The median of the cloud height predictions is within about 10% of the observed value. For both cloud width and/or height, there are a few models with large (factor of 3 or higher) overpredictions. Of the 17 models, when compared to observations, there is a core group of 5 or 6 with consistently (across all three trials and all distances) less mean error and scatter in their predictions of arc max C and cloud width and height. However, as a group, the 17 models are performing adequately (using the “factor of two” rule of thumb). An important caveat is that, at the JR II desert site, chlorine deposition is minimal. At a site with vegetation and/or organic-rich soil, the effects of removal of chlorine by deposition are expected to be significant.
Hazardous substances with a boiling point close to ambient temperatures will evaporate at higher vapour pressures, so that the evaporation takes places in the smooth transition between the evaporation at boiling point and below boiling point, representing the transition between two different physical phenomena. Whilst the evaporation at boiling point is driven by the available heat flux, the evaporation below boiling point is driven by the concentration gradient between the pool surface and the ambient air. Available evaporation models usually focused on the correct description of the mass transfer coefficient for temperatures below boiling point. A formulation of the correct equation for the mass flow is rarely documented. Whilst the mass transfer coefficient formulation is more or less equivalent in most models, the main difference occurs in the formulation of the mass flow equation. In Fact two types of models can be identified: the models with a linear pressure term and the models with a logarithmic pressure term. Whilst the logarithmic formulations result in an infinite mass flow near boiling point, which is not plausible, the linear formulations reach (different) finite values. Due to a lack of published experimental data it was not possible to determine whether the linear approach is conservative, under predicting or more or less accurate close to the boiling point. To evaluate the accuracy of each type of formulation, test series on liquid pools have been carried out at BAM for substances like Water, Ethanol, Cyclohexane, and Acetone. The tests were done under ambient conditions with a heatable, 90 cm diameter pool, so that the vapour pressures investigated ranged from 0 to close to 1 bar. The experimental data showed that neither of the linear nor the logarithmic formulation of the evaporation models is able to predict correctly the mass flow close to the boiling point. The logarithmic approach heavily over predicts the mass flow, while the linear approach is not conservative anymore when the vapour pressure exceeds 0.7 bar.
When handling flammable or toxic liquids or liquefied gases, the occurrence of a leakage and formation of a liquid pool is a scenario to be considered for risk assessment. Several models are available for the estimation of the evaporating mass flow, but only a very reduced number of experimental data is available for Validation purposes.
In the last years, the Federal Institute for Materials Research and Testing (BAM) in Berlin, Germany, carried out pool Evaporation experiments with different substances in basins with a Diameter ranging from 0,50 m to 1 m mainly on open air test sites with a built up (inner city) and a non-built-up (flat terrain) topography, but also in an enclosed space. The resulting experimental data sets cover a range of vapor pressures from 0,1 bar to 0,94 bar.
The aim of this work is to make the füll data set publicly available and to provide a description of the experimental boundary conditions.
Based on these data, a Validation of existing pool Evaporation models has been carried out and eventually led to a new formulation of an evaporation model, which is also presented here, covering the whole ränge from low wind speeds up to high vapor pressures.
Commercial, off-the shelf propane cylinders are subjected to high safety regulations. Furthermore, those cylinders are equipped with safety devices like pressure relief valves (PRV). Despite these regulations and safety measures, a failure of the container is possible if exposed to an intense fire. The result of this is severe hazard for users, rescue forces and infrastructure. Within the framework of a destructive test series, 15 identical propane cylinders, without pressure relief devices, were exposed to an intensive fire in horizontal position until failure. Each cylinder was filled with a mass of m =11 kg of liquid propane. Three different fire sources were used (wood, petrol, propane). The experiments revealed the failure of all cylinders in a time period t < 155 s. The failure lead to a fragmentation into several major parts with throwing distances of up to l =262 m. In all trials, the temperature of the cylinder wall (top, side, bottom), of the liquid phase inside and of the surrounding fire (top, side, bottom) was recorded. In addition, the inner cylinder pressure and the induced overpressure of the blast wave after the failure were recorded. Overpressures of up to p=0.27 bar were recorded close to the cylinder (l =5 m). All tests were documented by video from several positions (general view, close-up, high-speed 5000 fps). This test series creates the basis for further experimental studies in the field of alternative fuels for vehicles. The aim of this test series is to assess and analyse the consequences of the failure of gas vessels (for LPG, CNG, CGH2) in the aftermath of severe incidents.
Pipe integrity is a central concern regarding technical safety, availability, and environmental compliance of industrial plants and pipelines. A condition monitoring system that detects and localizes threats in pipes prior to occurrence of actual structural failure, e.g., leakages, especially needs to target transient events such as impacts on the pipe wall or pressure waves travelling through the medium. In the present work, it is shown that fiber-optic distributed acoustic sensing (DAS) in conjunction with a suitable application geometry of the optical fiber sensor allows to track propagating acoustic waves in the pipeline wall on a fast time-scale. Therefore, short impacts on the pipe may be localized with high fidelity. Moreover, different acoustic modes are identified, and their respective group velocities are in good agreement with theoretical predications. In another set of experiments modeling realistic damage scenarios, we demonstrate that pressure waves following explosions of different gas mixtures in pipes can be observed. Velocities are verified by local piezoelectric pressure transducers. Due to the fully distributed nature of the fiber-optic sensing system, it is possible to record accelerated motions in detail. Therefore, in addition to detection and localization of threatening events for infrastructure monitoring, DAS may provide a powerful tool to study the development of gas explosions in pipes, e.g., investigation of deflagration-to-detonation-transitions (DDT).
Compressed natural gas (CNG) is a widely used automotive fuel in a variety of countries. In case of a vehicle fire where the safety device also malfunctions, a failure of the CNG automotive cylinder could occur. Such a cylinder failure is associated with severe hazards for the surrounding environment. Firstly, a comprehensive analysis is given below, summarizing various accidents involving CNG automotive cylinders and their consequences. In an extensive experimental program, 21 CNG automotive cylinders with no safety device were tested. Of the 21, burst tests were carried out on 5 Type III and 5 Type IV cylinders. Furthermore, fire tests with 8 Type III and 3 Type IV cylinders were conducted. Apart from cylinder pressure, inner temperature and cylinder mantle temperature, the periphery consequences, such as nearfield blast pressure and fragmentation are documented. The maximum measured overpressure due to a Type III cylinder failure was p = 0.41 bar. Each traceable fragment was georeferenced. All-in-all, fragment throw distances of d > 300 m could be observed. As one key result, it can be stated that the tested Type IV CNG cylinders showed less critical failure behavior then the Type III cylinders under fire impingement.
In case of a vehicle fire, an installed LPG (liquefied petroleum gas) tank with a malfunctioning safety device poses severe hazards. To investigate the consequences in case of tank failure, we conducted 16 tests with toroidal shaped LPG vehicle tanks. Three tanks were used for a Hydraulic Burst Test under standard conditions. Another three tanks were equipped with a statutory safety device and were subjected to a gasoline pool fire. The safety device prevented tank failure, as intended. To generate a statistically valid dataset on tank failure, ten tanks without safety devices were exposed to a gasoline pool fire. Five tanks were filled to a level of 20 %; the re-maining five were filled to a level of 100 %. In order to gain information on the heating process, three tem-perature readings at the tank surface, and three nearby flame temperatures were recorded. At distances of l = (7; 9; 11) m to the tank, the overpressure of the shock wave induced by the tank failure and the unsteady tem-peratures were measured. All ten tanks failed within a time of t < 5 min in a BLEVE (boiling liquid expanding vapor explosion). Seven of these resulted directly in a catastrophic failure. The other three resulted in partial failure followed by catastrophic failure. A near field overpressure at a distance of l = 7 m of up to p = 0.27 bar was measured. All ten tests showed massive fragmentation of the tank mantle. In total, 50 fragments were found. These 50 fragments make-up 88.6 % of the original tank mass. Each fragment was georeferenced and weighed. Fragment throwing distances of l > 250 m occurred. For the tanks with a fill level of 20 %, the average number of fragments was twice as high as it was for the tanks that were filled completely.
Industrial piping systems are particularly relevant to public safety and the continuous availability of infrastructure. However, condition monitoring systems based on many discrete sensors are generally not well-suited for widespread piping systems due to considerable installation effort, while use of distributed fibre-optic sensors would reduce this effort to a minimum. Specifically distributed acoustic sensing (DAS) is employed for detection of third-party threats and leaks in oil and gas pipelines in recent years and can in principle also be applied to industrial plants. Further possible detection routes amenable by DAS that could identify damage prior to emission of medium are subject of a current project at BAM, which aims at qualifying distributed fibre optic methods such as DAS as a means for spatially continuous monitoring of industrial piping systems. Here, first tests on a short pipe are presented, where optical fibres were applied directly to the surface. An artificial signal was used to define suitable parameters of the measurement system and compare different ways of applying the sensor.
In the presented work, the potential of fiber-optic distributed acoustic sensing (DAS) for detection of small gas pipeline leaks (<1%) is investigated. Helical wrapping of the sensing fiber directly around the pipeline is used to increase the system sensitivity for detection of weak leak-induced vibrations. DAS measurements are supplemented with reference accelerometer data to facilitate analysis and interpretation of recorded vibration signals. The results reveal that a DAS system using direct fiber application approach is capable of detecting pipeline natural vibrations excited by the broadband noise generated by the leaking medium. In the performed experiment, pipeline vibration modes with acceleration magnitudes down to single ug were detected. Simple leak detection approach based on spectral integration of time-averaged DAS signals in frequency domain was proposed. Potential benefits and limitations of the presented monitoring Approach were discussed with respect to its practical applicability. We demonstrated that the approached is potentially capable of detection and localization of gas pipeline leaks with leak rates down to 0.1% of the pipeline flow volume and might be of interest for monitoring of short- and medium-length gas pipelines.