Within the framework of the European project PICASSO, the radiographic simulator aRTist (analytical
Radiographic Testing inspection simulation tool) developed by BAM has been extended for reliability
assessment of film and digital radiography. A simulation supported probability of detection (POD) methodology
has been developed and the validity of the approach has been studied using an application from the aeronautics
industry. An experimental POD has been determined with the help of a specialized software tool, developed to
aid with the collection of large series of POD data. The resulting POD is compared to simulations of the same
setting using aRTist and the newly available module for simulation supported POD. A quantitative agreement
within a few percent is achieved between the experimental and the simulation supported POD.