Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (47)
- Vortrag (9)
- Beitrag zu einem Tagungsband (7)
- Posterpräsentation (4)
- Beitrag zu einem Sammelband (2)
- Forschungsbericht (2)
- Buchkapitel (1)
Sprache
- Englisch (50)
- Deutsch (21)
- Mehrsprachig (1)
Schlagworte
- XPS (23)
- ToF-SIMS (10)
- NEXAFS (7)
- ESCA (6)
- Microarrays (5)
- Surface analysis (4)
- Carbohydrates (3)
- Plasma polymers (3)
- SIMS (3)
- Self-assembled monolayer (3)
- Amino-functionalized surfaces (2)
- Atmospheric pressure plasma treatment (2)
- CD-XPS (2)
- Calibration (2)
- Chemical imaging (2)
- ESCA/XPS (2)
- Electron microscopy (2)
- Ellipsometry (2)
- Gold (2)
- Inter-laboratory comparison (2)
- Key comparison (2)
- Low pressure plasma pretreatment (2)
- Molecular orientation at polymer surfaces (2)
- Oberflächenanalytik (2)
- Plasma (2)
- Plasma treatment (2)
- Poly(propylene) (PP) (2)
- Polycarbonate (2)
- Polyurethane-polypropylene adhesion (2)
- Relevance of functional groups to adhesion (2)
- Self-assembled monolayers (2)
- Short-time exposure (2)
- SiO2 (2)
- Silicon dioxide (2)
- Synchrotron XPS (2)
- Thickness (2)
- Uncertainty (2)
- A. Magnesium (1)
- AES (1)
- Ageing (1)
- Ageing process (1)
- Alcohol (1)
- Amine (1)
- Amine-SAM (1)
- Amines (1)
- Amino surfaces (1)
- Amorphous materials (1)
- Analysis (1)
- Attenuation length (1)
- Ball milling (1)
- Beschichtung (1)
- Binding energy (1)
- Biomolecular interfaces (1)
- Brake (1)
- C. Hydrogen embrittlement (1)
- C. Stress corrosion (1)
- C. Welding (1)
- CCQM (1)
- Carbon (1)
- Catalyst (1)
- Chemical derivatisation (1)
- Chemical derivatization (1)
- Chromium(III) compound (1)
- Contact angle measurements (1)
- Coordination polymers (1)
- Cr(OH)3 (1)
- Cr2O3 (1)
- CrCl3 (1)
- CrF3 (1)
- CrF3.3H2O (1)
- Degradation (1)
- Depth profile (1)
- Depth profiling (1)
- Derivatisation (1)
- EDX (1)
- Elastomere (1)
- Electron effective attenuation length (1)
- Elektronenspektroskopie (1)
- Epoxy silane (1)
- Epoxy-functionalized surfaces (1)
- Fe-Ni alloy (1)
- Fe-Ni alloy film (1)
- Fluorescence (1)
- Friction layer (1)
- Functional group quantification (1)
- GIXRR (1)
- Imaging XPS (1)
- Interlaboratory comparison (1)
- Interlaboratory study (1)
- MEIS (1)
- Maleimide surfaces (1)
- Metallo-supramolecular chemistry (1)
- Micro technology (1)
- Micro-fluidic device (1)
- Microarray (1)
- Multiplet splitting (1)
- Mössbauer spectroscopy (1)
- NEXAFS/XANES (1)
- NRA (1)
- Nano-materials (1)
- Near edge X-ray absorption fine structure (NEXAFS) (1)
- Neutron reflectometry (1)
- Nona-mannoside (1)
- OTS Self-Assembled Layers (1)
- Organic coatings (1)
- Overlayer (1)
- Oxygen plasma (1)
- PMMA (1)
- Pd 3d (1)
- Photoelectron spectroscopy (1)
- Photoelectron spectroscopy (PES) (1)
- Photoluminiszenz (1)
- Plasma processing and deposition (1)
- Poly(acetylene) (1)
- Polymer (1)
- Powder chromium(III) compounds (1)
- Primary amines (1)
- Principal component analysis (1)
- Quantification (1)
- Quantitative surface chemical analysis (1)
- RBS (1)
- Raman spectroscopy (1)
- Reference material (1)
- Röntgenphotonspektroskopie (1)
- SAM (1)
- Satellite (1)
- Self-assembly (1)
- Silicone (1)
- Silikon, funkenerodiert (1)
- Stainless steel (1)
- Standard operation procedure (1)
- Structural properties (1)
- Surface (1)
- Surface chemical analysis (1)
- Surface modification (1)
- Surfaces (1)
- TEM (1)
- TOF-SIMS (1)
- Terphenylthiolate SAMs (1)
- Thin films (1)
- Thiols (1)
- Third body material (1)
- Topography free (1)
- Traceability (1)
- Transmission electron microscopy (1)
- Ultra-thin oxide (1)
- Vacuum ultraviolet photopolymers (1)
- Vesicles (1)
- Wettability (1)
- X-ray (1)
- X-ray diffraction (1)
- X-ray photoelectron spectroscopy (1)
- X-ray photoelectron spectroscopy (XPS) (1)
- XAES (1)
- XPS/ESCA (1)
- silica nanoparticles (1)
- surface and in-depth inspection (1)
- titania nanoparticles (1)
Eingeladener Vortrag
- nein (9)
The combination of complementary characterization techniques such as SEM (Scanning Electron Microscopy), T-SEM (Scanning Electron Microscopy in Transmission Mode), EDX (Energy Dispersive X-ray Spectroscopy) and SAM (Scanning Auger Microscopy) has been proven to be a powerful and relatively quick characterization strategy for comprehensive morphological and chemical characterization of individual silica and titania nanoparticles. The selected real life test materials, silica and titania, are listed in the OECD guidance manual as representative examples because they are often used as commercial nanomaterials. Imaging by high resolution SEM and in the transmission mode by T-SEM allows almost simultaneous surface and in-depth inspection of the same particle using the same instrument. EDX and SAM enable the chemical characterization of bulk and surface of individual nanoparticles. The core–shell properties of silica based materials are addressed as well. Titania nominally coated by silane purchased from an industrial source has been found to be inhomogeneous in terms of chemical composition.
First results of an inter-laboratory comparison (27 participants in Europe, Japan and USA) of XPS data obtained with non-conducting samples are presented. Binding energies of Al 2s for alumina, N 1s and imide C 1s for Kapton and Sr 3p3/2 for a strontium titanate film on glass were obtained after static charge referencing with the help of 15 nm gold particles deposited at the surface of the test samples. For the alumina sample C 1s static charge referenced data are also presented. Repeat standard deviations (sr), between standard deviations (sb), reproducibility standard deviations (sR) and total means are evaluated from the experimental data. It can be stated that although the repeat standard deviation is as small as 0.05 eV in the best case, the standard deviation characterizing the reproducibility of the method is obviously not better than 0.15 eV in the best case at the present time. The knowledge of these standard deviations is important for metrology, validations of analytical procedures relying on qualitative photoelectron spectroscopy and XPS databanking.
Nitrogen rich plasma polymer films (L-PPE:N) were prepared by low-pressure RF plasma using a 1:1 mixture of ethylene and ammonia and aged for 345 d in four different ambient conditions: (i) at room temperature (RT) in air; (ii) at RT in nitrogen; (iii) at -20?°C in air and; (iv) at –20 °C in nitrogen. The films were analyzed by X-ray photoelectron spectroscopy (XPS) and by time-of-flight secondary ion mass spectrometry (ToF-SIMS) at various intervals over the duration of the experiment. The ageing of primary amines, NH2, was followed by chemical derivatization with 4-trifluoromethyl benzaldehyde. Storage at –20 °C, mostly independently of ambient atmosphere, slowed down ageing to almost undetectable levels as evaluated by the analytical methods used for this study.
The chemical composition of the functional surfaces of substrates used for microarrays is one of the important parameters that determine the quality of a microarray experiment. In addition to the commonly used contact angle measurements to determine the wettability of functionalized supports, X-ray photoelectron spectroscopy (XPS) and time-of-flight secondary ion mass spectrometry (ToF-SIMS) are more specific methods to elucidate details about the chemical surface constitution. XPS yields information about the atomic composition of the surface, whereas from ToF-SIMS, information on the molecular species on the surface can be concluded. Applied on printed DNA microarrays, both techniques provide impressive chemical images down to the micrometer scale and can be utilized for label-free spot detection and characterization. Detailed information about the chemical constitution of single spots of microarrays can be obtained by high-resolution XPS imaging.
The Key Comparison K67 and the parallel Pilot Study P108 on quantitative analysis of thin alloy films have been completed in the Surface Analysis Working Group (SAWG) of the Consultative Committee for Amount of Substance (CCQM). The aim of these inter-laboratory comparisons is to determine the degree of equivalence in the measurement capability of national metrology institutes (NMIs) and designated institutes (DIs) for the determination of the composition of thin alloy films. The measurand is expressed in atomic percent. A Fe-Ni alloy film with a certified composition was available for the participants of the inter-laboratory comparison. It has been used as a reference specimen to determine the relative sensitivity factors (RSF) of Fe and Ni for the different analytical methods used by the participants to determine the composition of the test sample. As was shown in the preceding Pilot Study P98, the degrees of equivalence in the measurement capabilities of the participants can be improved in that way. The composition of the reference specimen was certified by inductively coupled plasma mass spectrometry (ICP-MS) using the isotope dilution method. The in-depth and lateral homogeneity, determined in terms of elemental composition, of the certified reference sample and the unknown test sample were confirmed by secondary ion mass spectrometry (SIMS) using C60 primary ions by the leading laboratory. Five laboratories participated in the key comparison. Four of them used x-ray photoelectron spectroscopy (XPS) and one Auger electron spectroscopy (AES). One laboratory participated in the parallel P108 pilot study using electron probe micro analysis with an energy-dispersive spectrometer (ED EPMA) and XPS.
Recently, time-of-flight secondary ion mass spectrometry (ToF-SIMS) and X-ray photoelectron spectroscopy (XPS) instrumentation has been used to address areas of interest within micro-fluidic devices providing full access to the surface chemistry established at the bottom of micro-channels therein. After careful calibration, information on surface chemistry as obtained by ToF-SIMS or XPS can be interpreted in terms of wettability expressed as contact angles which are then characteristic for the inner walls of micro-channels. Standard contact angle measurement is not applicable in micro-channels. The approach has been demonstrated to be successful with two different micro-fluidic devices hot embossed into high-end quality poly(methyl methacrylate) (PMMA) or Polycarbonate wafers. A pre-selected surface chemistry at micro-channel walls can be established by plasma technologies but ageing and rinsing effects have to be under control. A combination of ToF-SIMS, XPS and contact angle measurement techniques has been demonstrated to provide the required information. Finally, it is shown by ToF-SIMS and XPS analysis that in the production of micro-fluidic parts during practical processing using hot embossing technologies, material originating from cover foils will reside on the polymer wafer's surface. Moreover, residues of releasing agents as silicone oil used during processing can be detected by ToF-SIMS. Both cover foil residues and silicones are issues of trouble shooting in micro-fluidics because they will change contact angles efficiently.
Reference materials without variations in topography are essential for the characterization of imaging XPS (X-ray Photoelectron Spectroscopy) Instruments. Therefore a new fabrication process for this kind of zero-topography reference material was developed at PTB and resulted in first prototypes. The fabrication process and first measurement results will be presented in this paper.
An international interlaboratory comparison of the measurement capabilities of four National Metrology Institutes (NMIs) and one Designated Institute (DI) in the determination of the chemical composition of thin Fe-Ni alloy films was conducted via a key comparison (K-67) of the Surface Analysis Working Group of the Consultative Committee for Amount of Substance. This comparison was made using XPS (four laboratories) and AES (one laboratory) measurements. The uncertainty budget of the measured chemical composition of a thin alloy film was dominated by the uncertainty of the certified composition of a reference specimen which had been determined by inductively coupled plasma mass spectrometry using the isotope dilution method. Pilot study P-98 showed that the quantification using relative sensitivity factors (RSFs) of Fe and Ni derived from an alloy reference sample results in much more accurate result in comparison to an approach using RSFs derived from pure Fe and Ni films. The individual expanded uncertainties of the participants in the K-67 comparison were found to be between 2.88 and 3.40 atomic %. The uncertainty of the key comparison reference value (KCRV) calculated from individual standard deviations and a coverage factor (k) of 2 was 1.23 atomic %.