Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (31) (entfernen)
Sprache
- Englisch (31)
Schlagworte
- X-ray refraction (16)
- Computed tomography (5)
- Additive manufacturing (3)
- Microcracking (3)
- Pore orientation (3)
- Porosity (3)
- Synchrotron X-ray refraction radiography (3)
- BAMline (2)
- Chaboche model (2)
- Creep (2)
- Damage (2)
- Diffraction Enhanced Imaging (2)
- GTN model (2)
- Metal matrix composites (2)
- Microscopy (2)
- Porous ceramics (2)
- Refraction (2)
- Selective laser melting (2)
- Synchrotron (2)
- Synchrotron radiation (2)
- X-Ray Refraction (2)
- X-ray computed tomography (2)
- X-ray imaging (2)
- 2101 duplex stainless steel (1)
- 3D microstructure (1)
- 3D printing (1)
- 3D printing Polyamide 12 (1)
- Additive manufacturing (AM) (1)
- AlSi10Mg alloy (1)
- Aluminium alloys (1)
- Analyzer-Based Imaging (1)
- Beta-eucryptite (1)
- CMAS (1)
- CT (1)
- Carbon Fiber Reinforced Plastics (1)
- Cavitation (1)
- Ceramic matrix composite (1)
- Ceramic matrix composites (1)
- Ceria (1)
- Characterization (1)
- Composite materials (1)
- Composites (1)
- Computed Tomography (1)
- Crack detection (1)
- Crack evolution (1)
- Crystal Texture (1)
- Crystal structure (1)
- DIVA Algorithm (1)
- Damage evolution (1)
- Defects (1)
- Delamination (1)
- Diesel Fuel (1)
- Diesel Particulate Filter Materials (1)
- Diesel particulate filters (1)
- Electro-fused zirconia (1)
- Electron microscopy (1)
- Extrusion (1)
- Fe2TiO5 (1)
- Fiber de-bonding (1)
- Glass-ceramic (1)
- Grating interferometry (1)
- Homogenization schemes (1)
- Hydrogen embrittlement (1)
- Hystersis (1)
- INCONEL 718 (1)
- Impurity segregation (1)
- In situ tensile test (1)
- Interface (1)
- Internal Surfaces (1)
- Laser powder bed fusion (LPBF) (1)
- Material and damage behaviour (1)
- Material science (1)
- Micro analysis (1)
- Microcracked ceramics (1)
- Microstructure (1)
- Microstructure-property relations (1)
- Non-Destructive Evaluation (1)
- Nonlinear behavior (1)
- Nonlinear stress-strain curve (1)
- PE-HD Sorption (1)
- Phase grating (1)
- Phase transformation (1)
- Plasticity (1)
- Polyamide 12 (1)
- Pore Orientation (1)
- Porous Ceramics (1)
- Preferred orientation (1)
- Pseudo-Voigt fit function (1)
- Python (1)
- Radiography (1)
- Refractory (1)
- Scanning transmission electron microscopy (1)
- Si network disintegration (1)
- Specific surface (1)
- Statistically relevant volumes (1)
- Stiffness (1)
- Strain hardening (1)
- Synchrotron Radiation (1)
- Synchrotron X-ray refraction (1)
- Synchrotron X‐ray refraction radiography (1)
- Synchrotron imaging (1)
- Synchrotron x-ray refraction radiography (SXRR) (1)
- Synchrotron, BAMline (1)
- Talbot-Lau interferometer (1)
- Talbot-Lau interferometry (1)
- Tensile load (1)
- Thermal barrier coatings (1)
- Thermal expansion (1)
- Thermally induced porosity (TIP) (1)
- Thermoelectrics (1)
- Tomography (1)
- Viscoplastic (1)
- Visibility (1)
- WAXS (1)
- X-Ray Computed Tomography (1)
- X-ray (1)
- X-ray phase contrast (1)
- X-ray reefraction (1)
- X-ray refraction radiography (1)
- Zirconia (1)
- subgrain structure (1)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (24)
- 8.5 Röntgenbildgebung (24)
- 5 Werkstofftechnik (3)
- 5.3 Polymere Verbundwerkstoffe (2)
- 6 Materialchemie (2)
- 5.4 Multimateriale Fertigungsprozesse (1)
- 6.1 Oberflächen- und Dünnschichtanalyse (1)
- 6.3 Strukturanalytik (1)
- 7 Bauwerkssicherheit (1)
- 7.5 Technische Eigenschaften von Polymerwerkstoffen (1)
Paper des Monats
- ja (1)
The microstructure of an apatite-wollastonite (code name AP40) glass-ceramic is analyzed in this study by combining 2D microscopy, phase analysis, X-ray absorption and synchrotron X-ray refraction computed tomography (XCT and SXRCT, respectively). It is shown that this combination provides a useful toolbox to characterize the global microstructure in a wide scale range, from sub-micrometer to millimeter. The material displays a complex microstructure comprising a glassy matrix with embedded fluorapatite and wollastonite small crystals. In this matrix, large (up to 200 μm) spike-shaped structures are distributed. Such microstructural features are oriented around a central sphere, thereby forming a structure resembling a sea urchin. A unique feature of SXRCT, in contrast to XCT, is that internal interfaces are visualized; this allows one to show the 3D distribution of these urchins with exceptionally good contrast. Furthermore, it is revealed that the spike-shaped structures are not single crystals, but rather composed of sub-micrometric crystals, which are identified as fluorapatite and diopside phases by SEM-EDX analysis.
Talbot-Lau interferometry provides X-ray imaging techniques with significant enhancement of the radiographic contrast of weakly absorbing objects. The grating based technique allows separation of absorption, refraction and small angle scattering effects. The different efficiency of rectangular and triangular shaped phase gratings at varying detector distances is investigated. The interference patterns (Talbot carpets) are modeled for parallel monochromatic radiation and measured by synchrotron radiation. In comparison to rectangular shapes of phase gratings much higher visibility is obtained for triangular shapes which yield enhanced contrast of a glass capillary test specimen.
The performance of grating interferometers coming up now for Imaging interfaces within materials depends on the efficiency (visibility) of their main component, namely the phase grating. Therefore, experiments with monochromatic synchrotron radiation and corresponding simulations are carried out. The visibility of a Phase grating is optimized by different photon energies, varying detector to grating distances and continuous rotation of the phase grating about the grid lines. Such kind of rotation changes the projected grating shapes, and thereby the distribution profiles of phase shifts. This yields higher visibilities than derived from ideal rectangular shapes. By continuous grating rotation and variation of the propagation distance, we achieve 2D visibility maps. Such maps provide the visibility for a certain combination of grating orientation and detector position. Optimum visibilities occur at considerably smaller distances than in the standard setup.
For the first time, synchrotron X-ray refraction radiography (SXRR) has been paired with in-situ heat treatment to monitor microstructure and porosity evolution as a function of temperature. The investigated material was a laser powder bed fusion (LPBF) manufactured AlSi10Mg, where the initial eutectic Si network is known to disintegrate and spherodize into larger particles with increasing temperature. Such alloy is also prone to thermally induced porosity (TIP). We show that SXRR allows detecting the changes in the Si-phase morphology upon heating, while this is currently possible only using scanning electron microscopy. SXRR also allows observing the growth of pores, usually studied via X-ray computed tomography, but on much smaller fields-of-view. Our results show the great potential of in-situ SXRR as a tool to gain in-depth knowledge of the susceptibility of any material to thermally induced damage and/or microstructure evolution over statistically relevant volumes.
The material and damage behaviour of additively manufactured polyamide 12 under cyclic loading was characterized by cyclic tests and microstructure analysis by using microscopy, X-ray refraction, and computed tomography. The results were used to determine parameters for the viscoplastic material model by Chaboche and a damage model by Gurson-Tvergaard-Needleman. The temperature was monitored during the experiments and the self-heating effect was observed. By including this effect, a higher accuracy could be achieved with the results of mechanical experiments.
In order to characterise the material and damage behaviour of additively manufactured polyamide 12 (PA12) under quasi-static load and to implement it in a numerical model, experiments under quasi-static load as well as microstructural investigations were carried out. Selective laser sintering (SLS) was used as the manufacturing process. For the classification of the material behaviour, quasi-static cyclic tests with holding times as well as tensile tests were performed. X-ray refraction and computed tomography (CT) were used to investigate the damage behaviour. The Chaboche model, which has already been applied for metallic materials under thermomechanical loading, served as the basis for the selection of the numerical material model. The same procedure was used for the selection of the damage model, where the Gurson–Tvergaard–Needleman (GTN) model was chosen, which was already used for porous metallic materials. The Chaboche model shows very good agreement with experimental results. Furthermore, the coupling with the GTN model allows a very good modelling of the damage behaviour. Finally, it could be shown that the selected models are suitable to simulate the material and damage behaviour of 3D printed PA12.
Complementary to Part 1 of this work, the bi-continuous microstructure of porous synthetic cordierite ceramics for filtration applications was investigated using 3D x-ray computed tomography at different resolutions. Applying both Fast Fourier Transform and a newly developed image analysis algorithm, we quantitatively evaluated porosity and pore orientation. The statistical approach allows extraction of spatially resolved or average values. Porosity values based on x-ray absorption agree with mercury intrusion measurements, while pore orientation factors agree with x-ray refraction data (Part 1 of this work), and with published crystallographic texture data.
The in situ analysis of the damage evolution in a metal Matrix composite (MMC) using synchrotron X-ray refraction radiography (SXRR) is presented. The investigated material is an Al alloy (6061)/10 vol% Al2O3 MMC after T6 heat treatment.
In an interrupted tensile test the gauge section of dog bone-shaped specimens is imaged in different states of tensile loading. On the basis of the SXRR images, the relative change of the specific surface (proportional to the amount of damage) in the course of tensile loading was analyzed. It could be shown that the damage can be detected by SXRR already at a stage of tensile loading, in which no Observation of damage is possible with radiographic absorption-based imaging methods.
Moreover, the quantitative analysis of the SXRR images reveals that the amount of damage increases homogeneously by an average of 25% with respect to the Initial state. To corroborate the experimental findings, the damage distribution was imaged in 3D after the final tensile loading by synchrotron X-ray refraction computed tomography (SXRCT) and absorption-based synchrotron X-ray computed tomography (SXCT). It could be evidenced that defects and damages cause pronounced indications in the SXRCT images.
X-ray refraction is based on optical deflection of X-rays, similar to the well-known small angle X-ray scattering, but hundreds of times more intense, thus enabling shorter measurement time. We show that X-ray refraction techniques are suitable for the detection of pores, cracks, and in general defects. Indeed, the deflected X-ray intensity is directly proportional to the internal specific surface (i.e., surface per unit volume) of the objects. Although single defects cannot be imaged, the presence of populations of those defects can be detected even if the defects have sizes in the nanometer range.We present several applications of X-ray refraction techniques to composite materials:- To visualize macro and microcracks in Ti-SiC metal matrix composites (MMC);- To correlate fatigue damage (fibre de-bonding) of carbon fibre reinforced plastics (CFRP) to X-ray refraction intensity;- To quantify the impact damage by spatially resolved single fibre de-bonding fraction as a function of impact energy in CFRP laminates.An example of classic high-resolution computer tomography of an impact-damaged CFRP will also be presented, as a benchmark to the present state-of-the-art imaging capabilities. It will be shown that while (absorption) tomography can well visualize and quantify delamination, X-ray refraction techniques directly yield (spatially resolved) quantitative information about fibre de-bonding, inaccessible to absorption tomography.
Microstructure characterisation of advanced materials via 2D and 3D X-ray refraction techniques
(2018)
3D imaging techniques have an enormous potential to understand the microstructure, its evolution, and its link to mechanical, thermal, and transport properties. In this conference paper we report the use of a powerful, yet not so wide-spread, set of X-ray techniques based on refraction effects. X-ray refraction allows determining internal specific surface (surface per unit volume) in a non-destructive fashion, position and orientation sensitive, and with a nanometric detectability. We demonstrate showcases of ceramics and composite materials, where microstructural parameters could be achieved in a way unrivalled even by high-resolution techniques such as electron microscopy or computed tomography. We present in situ analysis of the damage evolution in an Al/Al2O3 metal matrix composite during tensile load and the identification of void formation (different kinds of defects, particularly unsintered powder hidden in pores, and small inhomogeneity’s like cracks) in Ti64 parts produced by selective laser melting using synchrotron X-ray refraction radiography and tomography.