The reliability investigations are dedicated to throw light on the performance of the NDE system with
respect to the required aim. This is especially of interest when digitized and processed signals are
involved where it becomes hard to assess whether the quality of the system has raised or not. Three
different ways to investigate reliability of NDE signals will be described. The first way of investigation,
the performance demonstration, is preferred e.g. in the US American nuclear power industry. This is an
integral consideration of the non destructive test as a system where the whole NDE system is packed in a
black box and only the input in terms of the real existing flaws in the component is considered and
compared to the output in terms of the indications of the human inspector or of the automated system.
The second the European tradition relies on a standardized description of physical/technical
parameters of the NDE system which are preconditions for successful system performance. An example
for such a standardized set of performance parameters is given in the recently released standard about Xray
film digitization CEN EN 14096. The third approach the modular conception is a marriage of
both: The signal chain is cut into main modules. Each module is assessed in a most appropriate
individual way e.g. via modeling calculations. The single results are joint together according to the
reliability of the subsystems. Separating criteria for the system were proposed through a reliability
formula developed during a series of European-American workshops on NDE reliability. Examples of
all three approaches will be given.
The last 25 years have seen an explosion in the number of new x-ray based imaging methods and applications. In reviewing these new capabilities we see that the ability to generate improved data quality underlies a number of the major advances. Improvement in the quality of x-ray sources, in detector resolution and dynamic range, in data analysis methods both in image processing and in reconstruction techniques have yielded significant advances in image quality. In addition to the improved imaging hardware, the use of computers play a key role in extending capabilities in high speed computed tomography, in real time image enhancement, in automated defect recognition and in the development of accurate x-ray inspection simulations. The ability to generate information and to analyze the complexities introduced by typical inspection demands can quickly outstrip even today's computational resources. Developments in parallel computing and computer memory are beginning to managing the huge data volumes now routinely produced and open up a number of new applications. Some examples include high-resolution 3D-image generation with the capability to probe micron length scales, dual energy computed tomography providing improved airport security, materials characterization techniques providing new tool for process development, and x-ray image formation modeling. The ability to model the details of the generation of bremsstrahlung radiation and its interaction with the complex geometry of the object under consideration provide for the first time a means to determine and quantify the optimal parameters for an inspection. These advances over the last 25 years represent exciting time in x-ray imaging, the impact of which will be played out in the next decade. ©2001 American Institute of Physics.