This paper presents the mechanical and tribological properties of
Polytetrafluoroethylene (PTFE) and Polyetheretherketone (PEEK)
matrix composites filled with short carbon fibers in cryogenic
environments. Tensile tests were performed at room temperature (RT)
in air and in LN2. Tribological experiments were carried out with a
pin-on-disc configuration at RT, in LN2, in LH2 and in LHe. PEEK
composites have a better tribological performance than PTFE materials
especially regarding the wear resistance.
Influence of the Temperature on the Tribological Behaviour of PEEK Composites in Vacuum Environment
(2008)
This paper describes tribological experiments carried out with polyetheretherketone (PEEK), filled with carbon fibres and solid lubricants (polytetrafluoroethylene (PTFE), graphite or MoS2), against steel discs. Oscillating sliding tests were performed in high vacuum environment in the temperature range between -40°C and +160°C. Results indicate that MoS2 filled PEEK show the best tribological performance in vacuum. Particularly, in the lower temperature range and at higher loads the friction behaviour is improved by the MoS2 content.
Influence of solid lubricant fillers on the tribological behaviour of peek composites in vacuum
(2009)
This paper focuses on the influence of the counterface materials on the sliding behaviour of polymer materials in hydrogen. Polyimide (PI), polyetheretherketone (PEEK) and Polytetrafluoroethylene (PTFE) materials were investigated against hardened 52100 martensitic bearing steel and 304 austenitic stainless steel with similar roughness (Ra = 0.2 μm). Results indicate that the friction and wear of PI and PEEK materials depend on the counterface material. This effect wasn’t observed for PTFE composites. While the tribological performance of polyimide is better against 52100 in hydrogen, improved sliding behaviour of PEEK materials is observed with 304 counterface, particularly at higher sliding speed. Surface analyses of the transfer film reveal that the influence of the counterface is primarily related to the chemical nature of the steel for PI and to the thermal conductivity of the disc for PEEK materials.
The development of hydrogen technologies is a key strategy to reduce greenhouse gas emission worldwide. Power-to-Gas is a challenging solution, in which hydrogen and methane can be used in mobility, industry, heat supply and electricity generation applications. This presentation deals with the tribological behaviour of polymer materials in hydrogen and methane, both in gas and in liquefied form.
Die Reibeigenschaften von PEEK-Materialien gegen Stahlscheiben wurden in Luft, Vakuum und Wasserstoffumgebung untersucht. Die Ergebnisse zeigen, dass reines PEEK umgebungsabhängig ist und die Desorption von Gasen im Vakuum zu hohen Verschleißraten führt. Die niedrigsten Verschleißraten sowohl in Vakuum als auch in einer Wasserstoffumgebung erzielen TiO2-Partikel. Ferner treten chemische Prozesse in den Materialien und im Tribokontakt auf und interagieren miteinander.
Windings in superconducting magnets operating at 4.2 K are highly susceptible to quenching caused by small frictional heat inputs. Small movements in the magnet system are inevitable during ramping due to the increasing electromagnetic forces. Friction pairs of polymer based materials have been investigated at 4.2 K to gain an understanding of their sliding behavior in conditions representative of superconducting MRI systems. The results indicate that polymer-polymer pairs experience unstable sliding behavior with repeated stick-slip whereas polymer-aluminum couples have stable sliding behavior up to high contact pressures of 20 MPa.