The results of analytical measurements performed with solid-sampling techniques are affected by the distribution of the analytes within the matrix. The effect becomes significant in case of determination of trace elements in small subsamples. In this framework we propose a measurement model based on Instrumental Neutron Activation Analysis to determine the relative variability of the amount of an analyte among subsamples of a material. The measurement uncertainty is evaluated and includes the counting statistics, the full-energy gamma peak efficiency and the spatial gradient of the neutron flux at the irradiation position. The data we obtained in a neutron activation experiment and showing the relative variability of As, Au, Ir, Sb and W among subsamples of a highly pure Rh foil are also presented.
Nanocomposites with a predominantly exfoliated morphology were prepared by melt blending of organically modified doubled layered hydroxide (LDH) and low density polyethylene (PE). The prepared materials were investigated by differential scanning calorimetry (DSC) and in detail by dielectric spectroscopy. The DSC experiments show that the degree of crystallinity decreases linearly with increasing content of the LDH. The extrapolation of this dependence to zero results in a limiting concentration of ca. 50 wt % LDH were the crystallization of PE is completely suppressed by the nanofiller. The dielectric response of pure polyethylene shows different weak relaxation processes. The intensity of dynamic glass transition (β-relaxation) increases with the concentration of LDH. This is attributed to the increasing concentration of the exchanged anion dodecyl benzene sulfonate (SDBS). The SDBS molecules are strongly adsorbed at the exfoliated LDH layers. Therefore, a detailed analysis of the β-relaxation provides information about the structure and the molecular dynamics in the interfacial region between the exfoliated LDH layers and the polyethylene matrix. This analysis shows that the β-relaxation region consists of two processes: both of them obey glassy dynamics. The difference in corresponding Vogel (ideal glass transition) temperatures is about 30 K. The relaxation process at lower frequency is assigned to polyethylene segments with a reduced molecular mobility close to LDH layers. The process at higher frequencies is related to polyethylene segments in a farer distance for the surface of the nanofiller. In the nanocomposite materials an additional process due to Maxwell-Wagner-Sillars (MWS) polarization was observed. The time constant of this MWS process can be correlated with characteristic length scales in nanocomposites and therefore provides additional information on dispersion and delamination/exfoliation of the LDH layers in these materials.
Gravimetrically prepared mono-elemental reference solutions having a well-known mass fraction of approximately 1 g/kg (or a mass concentration of 1 g/L) define the very basis of virtually all measurements in inorganic analysis. Serving as the starting materials of all standard/calibration solutions, they link virtually all measurements of inorganic analytes (regardless of the method applied) to the purity of the solid materials (high-purity metals or salts) they were prepared from. In case these solid materials are characterized comprehensively with respect to their purity, this link also establishes direct metrological traceability to The International System of Units (SI). This, in turn, ensures the comparability of all results on the highest level achievable. Several national metrology institutes (NMIs) and designated institutes (DIs) have been working for nearly two decades in close cooperation with commercial producers on making an increasing number of traceable reference solutions available. Besides the comprehensive characterization of the solid starting materials, dissolving them both loss-free and completely under strict gravimetric control is a challenging problem in the case of several elements like molybdenum and rhodium. Within the framework of the European Metrology Research Programme (EMRP), in the Joint Research Project (JRP) called SIB09 Primary standards for challenging elements, reference solutions of molybdenum and rhodium were prepared directly from the respective metals with a relative expanded uncertainty associated with the mass fraction of Urel(w)<0.05 %. To achieve this, a microwave-assisted digestion procedure for Rh and a hotplate digestion procedure for Mo were developed along with highly accurate and precise inductively coupled plasma optical emission spectrometry (ICP OES) and multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS) methods required to assist with the preparation and as dissemination tools.
The local structure around Ni and La atoms in Al85Ni10La5 amorphous powder after ball milling was investigated by X-ray absorption spectroscopy. A continuous decrease in coordination number of Ni and La as a function of milling time was observed, while the nearest neighbour distance and the mean square atomic displacement did not change, pointing at the creation of free volume around the Ni and La atoms. These structural changes resemble those of a liquid upon temperature increase. The results are described by a shear band model in which the coordination numbers of Ni and La are different within and outside a shear band.
Background. Post-menopausal osteoporosis is a common health problem worldwide, most commonly caused by estrogen deficiency. Most of the information regarding the skeletal effects of this disease relates to trabecular bone, while cortical bone is less studied. The purpose of this study was to evaluate the influence of estrogen deficiency on the structure and mechanical properties of cortical bone.
Methods. Eight ovariectomized (OVH) and eight intact (control) Sprague Dawley rats were used. Structural features of femoral cortical bone were studied by light microscopy, scanning electron microscopy and synchrotron-based microcomputer-tomography and their mechanical properties determined by nano-indentation.
Results. Cortical bone of both study groups contains two distinct regions: organized
circumferential lamellae and disordered bone with highly mineralized cartilaginous islands. Lacunar volume was lower in the OVH group both in the lamellar and disorganized regions (182 ± 75 µm3 vs 232 ± 106 µm3 , P < 0.001 and 195 ± 86 µm3 vs. 247 ± 106 µm3 , P < 0.001, respectively). Lacunar density was also lower in both bone regions of the OVH group (40 ± 18 ×103 lacunae/mm3 vs. 47 ± 9×103 lacunae/mm3
in the lamellar region, P = 0.003 and 63 ± 18×103 lacunae/mm3
vs. 75 ± 13×103 lacunae/mm3 in the disorganized region, P < 0.001). Vascular canal volume was lower in the disorganized region of the bone in the OVH group compared to the same Region in the control group (P < 0.001). Indentation moduli were not different between the study groups in both bone regions.
Discussion. Changes to cortical bone associated with estrogen deficiency in rats require high-resolution methods for detection. Caution is required in the application of These results to humans due to major structural differences between human and rat bone.
Flexible electrochromic devices (ECDs) based on Fe(II)-metallo-supramolecular polyelectrolytes (Fe-MEPE) and vanadium oxide are studied in operando by means of x-ray absorption fine structure (XAFS) spectroscopy. The ECDs are blue-purple in the colored state at 0.0 V and become light yellow when a voltage of 1.6 V is applied. The XAFS studies at the K-edge of Fe(II) reveals that the absorption edge is shifted toward higher energies by 1.8 eV in the transparent state. Comparison of two different ECDs and different charge cycles demonstrates the reversibility and repeatability of the process. We attribute the shift to a charge transfer and a change of oxidation state of the ions from Fe2+ to Fe3+. The transition is not accompanied by a noticeable structural change of the octahedral coordination geometry as confirmed by analysis of the extended x-ray absorption fine structure (EXAFS) data. (C) 2015 Elsevier B.V. All rights reserved.
Nanocomposites based on polypropylene (PP) and organically modified ZnAl layered double hydroxides (ZnAl-LDH) were prepared by melt blending and investigated by a combination of differential scanning calorimetry (DSC), small- and wide-angle X-ray scattering (SAXS and WAXS), and dielectric relaxation spectroscopy (DRS). An average number of stack size of LDH layers is calculated by analyzing the SAXS data which is close to that of pure organically modified ZnAl-LDH. Scanning microfocus SAXS investigations show that the ZnAl-LDH is homogeneously distributed in the PP matrix as stacks of 4–5 layers with an intercalated morphology. DSC and WAXS results show that the degree of crystallinity decreases linearly with the increasing content of LDH. The extrapolation of this dependence to zero estimates a limiting concentration of ca. 40% LDH where the crystallization of PP is completely suppressed by the nanofiller. The dielectric spectra of the nanocomposites show several relaxation processes which are discussed in detail. The intensity of the dynamic glass transition (β-relaxation) increases with the concentration of LDH. This is attributed to the increasing concentration of the exchanged anion dodecylbenzenesulfonate (SDBS) which is adsorbed at the LDH layers. Therefore, a detailed analysis of the β-relaxation provides information about the structure and the molecular dynamics in the interfacial region between the LDH layers and the polypropylene matrix which is otherwise dielectrically invisible (low dipole moment). As a main result, it is found that the glass transition temperature in this interfacial region is by 30 K lower than that of pure polypropylene. This is accompanied by a drastic change of the fragility parameter deduced from the relaxation map.
Organically modified ZnAl Layered Double Hydroxides (ZnAl-LDH) was synthesized and melt blended with polyethylene to obtain nanocomposites. The resulting morphology was investigated by a combination of Differential Scanning Calorimetry (DSC), Small and Wide-angle X-ray scattering (SAXS and WAXS) and dielectric relaxation spectroscopy (DRS). The arrangement (intercalation) of polyethylene chains between LDH stacks was investigated employing SAXS. The homogeneity of the nanocomposites and average number of stack size (4–6 layers) were determined using scanning microfocus SAXS (BESSY II). DSC and WAXS results show that the degree of crystallinity decreases linearly with the increasing content of LDH. The extrapolation of this dependence to zero estimates a limiting concentration of ca. 45% LDH where the crystallization of PE is completely suppressed by the nanofiller. The dielectric spectra of the nanocomposites show several relaxation processes which are discussed in detail. The intensity of the dynamic glass transition (β-relaxation) increases with the concentration of LDH. This is attributed to the increasing concentration of the exchanged anion sodium dodecylbenzene sulfonate (SDBS) which is adsorbed at the LDH layers. Therefore, a detailed analysis of the β-relaxation provides information about the structure and the molecular dynamics in the interfacial region between the LDH layers and the polyethylene matrix which is otherwise dielectrically invisible (low dipole moment).
Agglomerated superparamagnetic iron
oxide nanoparticles can easily and in large scale be
precipitated from iron salt solutions. Although the
process is well known, it is ambiguously either assumed
that magnetite or maghemite is obtained. The first part
of our study clarifies this question using X-ray absorption
spectroscopy. For further processing of the nanoparticles,
i.e., for giving them a surface functionality or
incorporating them into composites, it is important to
break the agglomerates and individualize the particles
at first. This can effectively be done with nitric acid
treatment. The influence of this process on the particles
chemistry and structure was analyzed in great detail
using X-ray diffraction, X-ray absorption, and smallangle
X-ray scattering. In contrast to our expectation,
no oxidation from magnetite (Fe3O4) to maghemite (γ-
Fe2O3) was found; the formal valence of the particles in
any case is magnetite (Fe3O4). Instead, an increase in
the particles' surface disorder was discovered from
X-ray absorption analyses and high-resolution transmission
electron microscopy. The acid treatment
roughens and distorts the surface of the nanoparticles
which is connected with an increased spin disorder.
Besides conventional scanning X-ray fluorescence imaging at synchrotron sources, full-field X-ray fluorescence (FF-XRF) imaging techniques that do not implicitly require spatial scanning of the sample have become available. FF-XRF has become achievable thanks to the development of a new type of energy dispersive CCD-based 2D detector, also referred to as a 'color X-ray camera (CXC)' or 'SLcam'. We report on different imaging schemes for biological samples using FF-XRF imaging: (a) 2D 'zoom' imaging with pinhole optics using the 'camera obscura' principle; (b) 2D 'fixed magnification' imaging using magnifying polycapillary optics; and (c) 3D-FF-XRF imaging using an X-ray sheet beam or computed tomography (CT). The different FF-XRF imaging modes are illustrated using the crustacean Daphnia magna, a model organism for investigating the effects of metals on organism/ecosystem health, and foraminifera, a class of amoeboid protist. Detailed analytical characterization of the set-up is performed through analyzing various reference materials in order to determine limits of detection (LODs) and sensitivities. Experiments were performed using the BAMline at the BESSY synchrotron (Berlin, Germany) and using the P06 Hard X-ray Microprobe at the PETRAIII synchrotron (Hamburg, Germany).
This key comparison aims to assess the core capabilities of the participants in gas analysis. Such competences include, among others, the capabilities to prepare Primary Standard gas Mixtures (PSMs), perform the necessary purity analysis on the materials used in the gas mixture preparation, the verification of the composition of newly prepared PSMs against existing ones, and the capability of calibrating the composition of a gas mixture. According to the Strategy for Key Comparisons of the Gas Analysis Working Group, this key comparison is classified as an RMO track A key comparison.
The artefacts were binary mixtures of propane in nitrogen at a nominal amount-of-substance fraction level of 1000 μmol/mol. The values and uncertainties from the gravimetric gas mixture preparation were used as key comparison reference values (KCRVs). Each transfer standard had its own KCRV. The results are generally good. All results are within ± 1 % of the KCRV.
CCQM-K118 was an international key comparison on natural gas composition with two types of gases, i.e., a low calorific hydrogen-enriched natural gas and a high calorific LNG type of gas. There were 14 participating laboratories. The traveling standards (i.e., 14 mixtures each) were obtained from an external source and checked for homogeneity and stability before and after the participants' measurements at the two coordinating laboratories. The data evaluation was performed using a consensus value and a laboratory effect model. The results of the participants were benchmarked against a key comparison reference value computed from the largest consistent subset (LCS) of the submitted results, adjusted for the differences between the travelling standards. For the first time in a key comparison in gas analysis, the model included a term to account for excess variability in the LCS. Most of the participants reported one or a few (slightly) discrepant results. Partly this is due to the heterogeneity and heteroscedasticity of the datasets. In all, the results in this key comparison demonstrate the good comparability of the national measurement standards for natural gas composition maintained by the participating NMIs.
Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.
The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/.
The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
We present a new high resolution X-ray imager based on a pnCCD detector and a polycapillary optics. The properties of the pnCCD like high quantum efficiency, high energy resolution and radiation hardness are maintained, while color corrected polycapillary lenses are used to direct the fluorescence photons from every spot on a sample to a corresponding pixel on the detector. The camera is sensitive to photons from 3 to 40 keV with still 30% quantum efficiency at 20 keV. The pnCCD is operated in split frame mode allowing a high frame rate of 400 Hz with an energy resolution of 152 eV for Mn Kα (5.9 keV) at 450 kcps. In single-photon counting mode (SPC), the time, energy and position of every fluorescence photon is recorded for every frame. A dedicated software enables the visualization of the elements distribution in real time without the need of post-processing the data. A description of the key components including detector, X-ray optics and camera is given. First experiments show the capability of the camera to perform fast full-field X-Ray Fluorescence (FF-XRF) for element analysis. The imaging performance with a magnifying optics (3×) has also been successfully tested.
Pilot studies have been carried out at the BAMline at BESSY II in collaboration with the Bundesanstalt
für Materialforschung und -prüfung (BAM) on metal- and metalloid-containing compounds in biological
samples after electrophoretic protein separation. After sodium dodecylsulfate polyacrylamide gel
electrophoresis (SDS-PAGE) and transfer onto a blotting membrane the distribution of selenium among
the proteins of testis homogenate of a rat and a wallaby was determined. The comparison with the
autoradiogram of 75Se-labeled proteins separated in the same way showed that of nine seleniumcontaining
proteins found in rat testis homogenate by autoradiography four could be detected by
synchrotron radiation X-ray fluorescence analysis (SRXRF).
The high-resolution synchrotron-based imaging stations at the BAMline (BESSY) and TopoTomo (ANKA)
(2008)
The BAMline at the BESSY light source in Berlin and the TopoTomo beamline at the ANKA synchrotron facility in Karlsruhe (both Germany) operate in the hard X-ray regime (above 6 keV) with similiar photon flux density. For typical imaging applications, a double multilayer monochromator or a filtered white beam is used. In order to optimise the field of view and the resolution of the available indirect pixel detectors, different optical systems have been installed, adapted, respectively, to a large field of view (macroscope) and to high spatial resolution (microscope). They can be combined with different camera systems, ranging from 16-bit dynamic range slow-scan CCDs to fast CMOS cameras. The spatial resolution can be brought substantially beyond the micrometer limit by using a Bragg magnifier. The moderate flux of both beamlines compared to other 3rd generation light sources is compensated by a dedicated scintillator concept. For selected applications, X-ray beam collimation has proven to be a reliable approach to increase the available photon flux density. Absorption contrast, phase contrast, holotomography and refraction-enhanced imaging are used depending on the application. Additionally, at the TopoTomo beamline digital white beam synchrotron topography is performed, using the digital X-ray pixel detectors installed.
By means of synchrotron X-ray computed tomography, model composites consisting of silica and styrenebutadiene rubber were studied with a very high spatial resolution. By our analysis technique we were able to determine the nano- and micro dispersion from the experimental results by our numerical analysis. These results are discussed with respect to crucial advantages of the generically 3-dimensional tomography technique as compared to 2-dimensional methods. Our quantitative analysis of the 3d images demonstrates that in the case of our model composites the filler dispersion is good, independent on the filler concentration. Our new 3-dimensional results evidence that considering only 2-d pictures may lead to ambiguities that can lead to wrong conclusions.