Filtern
Erscheinungsjahr
Dokumenttyp
Schlagworte
- EXAFS (3)
- Dielectric spectroscopy (2)
- Disorganized bone (2)
- Electrochromism (2)
- Local structure (2)
- Metallo-supramolecular polyelectrolytes (2)
- Micro-computed tomography (2)
- Rhodium (2)
- Silicon nitride (2)
- X-ray topography (2)
- XAFS (2)
- XANES (2)
- XRF (2)
- AIMD simulation (1)
- Additive Manufacturing (1)
- Al2O3-Y2O3-ZrO2 (1)
- Amorphous-alloys (1)
- Anisotropic grain growth (1)
- BAMline (1)
- Bragg magnification (1)
- CCQM (1)
- CCQM-K (1)
- CCQM-P107 (1)
- CXC (1)
- Cartilage islands (1)
- Ceramic (1)
- Coherent imaging (1)
- Copper alloys (1)
- Coprecipitation (1)
- Cortical bone (1)
- Cortical bone structure (1)
- Crystallization behavior (1)
- Cyclic voltammetry (1)
- D. ZrO2 (1)
- Deformation (1)
- Detector calibration (1)
- Digestion (1)
- Direct metal assay (1)
- Dispersion (1)
- Double-Crystal-Monochromator with sagittal bender (1)
- Double-Multilayer-Monochromator with meridional bender (1)
- EURAMET.QM-K111 (1)
- Electrochromic device (1)
- Electron-irradiation (1)
- Elemental analysis (1)
- Endochondral bone (1)
- Estrogen (1)
- Eutectic ceramics (1)
- Fast X-ray imaging (1)
- Ferrofluid (1)
- Frustration (1)
- Full-field X-ray fluorescence (1)
- Glass structure (1)
- Glass-ceramic (1)
- Glass-forming ability (1)
- Graded (1)
- High energy resolution (1)
- High purity metals (1)
- High quantum efficiency (1)
- High-purity elements (1)
- Holotomography (1)
- Homogeneity (1)
- ICP OES (1)
- Impurity assessment (1)
- Instrumental neutron activation analysis (1)
- Interlaboratory comparison (1)
- Iron oxide spectra (1)
- LAS (1)
- Lacunae (1)
- Lamellar bone (1)
- Laser (1)
- Laser processing (1)
- Laserwise-slurry-deposition (LSD) (1)
- Layered double hydroxide (1)
- Layered double hydroxides (1)
- Local current distribution (1)
- MC-ICP-MS (1)
- Maia detector (1)
- Mechanical properties (1)
- Metallic glasses (1)
- Metrological traceability (1)
- Metrology (1)
- Microbeam (1)
- Microstructure (1)
- Microtomography (1)
- Molybdenum (1)
- Multi-component alloy (1)
- Nanocomposites (1)
- Nanopowder (1)
- Neutron imaging technique (1)
- Nodular cast iron (1)
- Non-destructive evaluation (1)
- Non-metal analysis (1)
- Ovariectomy (1)
- PEM Fuel-cells (1)
- Polycapillary optics (1)
- Polyethylene nanocomposites (1)
- Polypropylene (1)
- Porosity (1)
- Porous ceramics (1)
- Positron lifetime (1)
- Propane in nitrogen (1)
- Purity (1)
- Purity analysis (1)
- Purity assessment (1)
- RFA (1)
- Rapid nitridation (1)
- Rat (1)
- Reaction bonding (1)
- Reference solution (1)
- Reflectometry (1)
- Röntgenfluoreszenzanalyse (1)
- SAXS (1)
- SI-traceability (1)
- Scanning SAXS (1)
- Scanning WAXS (1)
- Scintillator (1)
- Selective laser sintering (SLS) (1)
- Shear bands (1)
- Si3N4 (1)
- Si3N4/SiC porous ceramics (1)
- SiO2 (1)
- Silberstiftzeichnung (1)
- Silica (1)
- Silverpoint drawing (1)
- State (1)
- Strain analysis (1)
- Strength (1)
- Structural model (1)
- Styrene butadiene rubber (1)
- Synchrotron (1)
- Synchrotron based microtomography (1)
- Synchrotron instrumentation (1)
- Synchrotron radiation (1)
- Synchrotron-CT (1)
- Temperature (1)
- Thermal stability (1)
- Uncertainty (1)
- VHCF (very high cycle fatigue) (1)
- Vanadium oxide (1)
- Water transport (1)
- X-ray CCD camera (1)
- X-ray absorption spectra (1)
- X-ray fluorescence analysis (1)
- X-ray phase contrast (1)
- X-ray refraction (1)
- X-ray scattering (1)
- X-ray spectrometry (1)
- X-ray tomography (1)
- X-ray-diffraction (1)
- Zinc (1)
- pnCCD (1)
- µCT (1)
Organisationseinheit der BAM
For the first time, an international comparison was conducted on the determination of the purity of a high purity element. Participants were free to choose any analytical approach appropriate for their institute’s applications and services. The material tested was a high purity zinc, which had earlier been assessed for homogeneity and previously used in CCQM-K72 for the determination of six defined metallic impurities. Either a direct metal assay of the Zn mass fraction was undertaken by EDTA titrimetry, or an indirect approach was used wherein all impurities, or at least the major ones, were determined and their sum subtracted from ideal purity of 100 %, or 1 kg/kg. Impurity assessment techniques included glow discharge mass spectrometry, inductively coupled plasma mass spectrometry and carrier gas hot extraction/combustion analysis. Up to 91 elemental impurities covering metals, non-metals and semi-metals/metalloids were quantified. Due to the lack of internal experience or experimental capabilities, some participants contracted external laboratories for specific analytical tasks, mainly for the analysis of non-metals. The reported purity, expressed as zinc mass fraction in the high purity zinc material, showed excellent agreement for all participants, with a relative standard deviation of 0.011 %. The calculated reference value, w(Zn) = 0.999 873 kg/kg, was assigned an asymmetric combined uncertainty of + 0.000025 kg/kg and – 0.000028 kg/kg. Comparability amongst participating metrology institutes is thus demonstrated for the purity determination of high purity metals which have no particular difficulties with their decomposition / dissolution process when solution-based analytical methods are used, or which do not have specific difficulties when direct analysis approaches are used. Nevertheless, further development is required in terms of uncertainty assessment, quantification of non-metals and the determination of purity of less pure elements and/or for those elements suffering difficulties with the decomposition process.
The present study is dealing with the basic physics for a novel way to generate a free-formed ceramic body, not like common layer by layer, but directly by Selective Volume Sintering (SVS) in a compact block of ceramic powder. To penetrate with laser light into the volume of a ceramic powder compact it is necessary to investigate the light scattering properties of ceramic powders. Compared with polymers and metals, ceramic materials are unique as they offer a wide optical window of transparency. The optical window typically ranges from below 0.3 up to 5 µm wave length. In the present study thin layers of quartz glass (SiO2) particles have been prepared. As a function of layer thickness and the particle size, transmission and reflection spectra in a wave length range between 0.5 and 2.5 µm have been recorded. Depending on the respective particle size and by choosing a proper relation between particle size and wave length of the incident laser radiation, it is found that light can penetrate a powder compact up to a depth of a few millimeters. With an adjustment of the light absorption properties of the compact the initiation of sintering in the volume of the compact is possible.
Short-range order has been investigated in Zr69.5Cu12Ni11Al7.5 and Zr41.5Ti41.5Ni17 metallic glasses using X-ray absorption spectroscopy and ab initio molecular dynamics simulations. While both of these alloys are good glass formers, there is a difference in their glass-forming abilities (Zr41.5Ti41.5Ni17 > Zr69.5Cu12Ni11Al7.5). This difference is explained by inciting the relative importance of strong chemical order, icosahedral content, cluster symmetry and configuration diversity.
Within the National Metrology Institutes (NMIs) and designated laboratories, an interlaboratory comparison, CCQM-P107, was conducted to verify the degree of international comparability concerning the results of purity analysis. The mass fractions of Ag, Bi, Cd, Cr, Ni, Tl at the lower mg/kg-level in a high purity zinc material were determined, but the real measurand in metrological sense was the sum of the six mass fractions. Homogeneity was investigated by glow discharge mass spectrometry, reference values were obtained using isotope dilution mass spectrometry. Six NMIs participated, contributing eight independent data sets. The agreement amongst the results of the participants, their median and the agreement with the reference values were usually excellent and in almost all cases below the target uncertainty of 30% relative. In this manner, the accuracy of results and the comparability between the participants was demonstrated to be established.
The first hard X-ray beamline at BESSY II will be installed by BAM and PTB at a superconducting 7 T wavelength shifter. The main optical elements of the beamline are a Double-Multilayer-Monochromator and a Double-Crystal-Monochromator. The two devices can be used separately or in-line. Main applications of monochromatic radiation with photon energies up to 50 keV are X-ray fluorescence analysis, micro-computed tomography, X-ray topography, detector calibration and reflectometry. Calculable undispersed radiation up to 200 keV will be available for radiometric applications.
The impact of very high cycle fatigue (VHCF) load conditions on the microstructure of specimens consisting of nodular cast iron is analyzed by means of micro-computed tomography (µCT) utilizing both monochromatic synchrotron radiation and polychromatic X-ray tube radiation. Using 3D µCT, the microstructure in the region of the smallest cross-sections of shouldered round specimens is imaged in different stages of the VHCF loading. By digital image correlation (DIC) of these tomograms strain fields are analyzed three-dimensionally. Strain levels in the range of a few percent were detected. It is proven that a localization of strain allows to predict the site of the crack which precedes and induces the macroscopic failure of the specimens.
A new instrument for simultaneous microbeam small- and wide-angle X-ray scattering and X-ray fluorescence (SAXS/WAXS/XRF) is presented. The instrument is installed at the microfocus beamline at BESSY II and provides a beam of 10 µm size with a flux of about 109 photons s-1. A SAXS resolution up to 500 Å d-spacing and a range of scattering vectors of almost three orders of magnitude are reached by using a large-area high-resolution CCD-based detector for simultaneous SAXS/WAXS. The instrument is particularly suited for scanning SAXS/WAXS/XRF experiments on hierarchically structured biological tissues. The necessary infrastructure, such as a cryo-stream facility and an on-site preparation laboratory for biological specimens, are available.
Local structures of amorphous and quasicrystalline phases in Zr–Ti–Ni and Zr–Ti–Ni–Cu alloys have been studied by means of x-ray absorption spectroscopy. The amorphous phases show a high degree of icosahedral short-range order. In all investigated systems local order around Cu and Ni atoms was found to be nearly identical pointing to site substitution of Ni by Cu as the reason for an improved glass forming ability when Ni is partly substituted by Cu. The results strengthen an icosahedral cluster based approach for the structure of metallic glasses and indicate the importance of the medium-range order on glass formation.
Flexible electrochromic devices (ECDs) based on Fe(II)-metallo-supramolecular polyelectrolytes (Fe-MEPE) and vanadium oxide are studied in operando by means of x-ray absorption fine structure (XAFS) spectroscopy. The ECDs are blue-purple in the colored state at 0.0 V and become light yellow when a voltage of 1.6 V is applied. The XAFS studies at the K-edge of Fe(II) reveals that the absorption edge is shifted toward higher energies by 1.8 eV in the transparent state. Comparison of two different ECDs and different charge cycles demonstrates the reversibility and repeatability of the process. We attribute the shift to a charge transfer and a change of oxidation state of the ions from Fe2+ to Fe3+. The transition is not accompanied by a noticeable structural change of the octahedral coordination geometry as confirmed by analysis of the extended x-ray absorption fine structure (EXAFS) data. (C) 2015 Elsevier B.V. All rights reserved.