Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (31)
- Zeitschriftenartikel (15)
- Vortrag (12)
- Forschungsbericht (6)
- Beitrag zu einem Sammelband (1)
Schlagworte
- Acoustic emission analysis (6)
- Cracks (5)
- Durability (5)
- Digital image correlation (4)
- Grout (4)
- Grouted connection (4)
- Nano-silica (4)
- Spaltzugfestigkeit (4)
- Tensile strength (4)
- Concrete (3)
Organisationseinheit der BAM
- 7 Bauwerkssicherheit (26)
- 7.4 Baustofftechnologie (24)
- 7.2 Ingenieurbau (12)
- 7.1 Baustoffe (8)
- 8 Zerstörungsfreie Prüfung (7)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (4)
- 8.6 Faseroptische Sensorik (4)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (3)
- 2 Prozess- und Anlagensicherheit (2)
- 2.4 Prüfung und Bewertung von Explosivstoffen/Pyrotechnik (2)
Eingeladener Vortrag
- nein (12)
The interaction mechanism of ultrasonic waves with surface-breaking cracks in reinforced concrete has been studied. For this, a detailed numerical analysis of the medium was first conducted using the spectral finite element method. Subsequently, measurements were conducted on a reinforced beam sample before and after mechanical-load-induced cracking. It was concluded that for the considered configuration, waves passing through the cracks dominated the tip-diffracted ones. In addition, substantial changes in the travel time and amplitude of the signals were observed when cracks were present.
In this study two different types of nano-silica (nS) were applied in self-compacting concrete (SCC), both having similar particle size distributions (PSD), but produced through two different processes: fumed powder silica and precipitated silica in colloidal suspension. The influence of nano-silica on SCC was investigated with respect to the properties of concrete in fresh (workability) and hardened state (mechanical properties and durability). Additionally, the densification of the microstructure of the hardened concrete was verified by SEM and EDS analyses. The obtained results demonstrate that nano-silica efficiently used in SCC can improve its mechanical properties and durability. Considering the reactivity of the two applied nano-silicas, the colloidal type showed a higher reactivity at early age, which influenced the final SCC properties.
Für die rechnerische Dimensionierung der Betondecken im Oberbau von Verkehrsflächen für den Neubau sowie die Erneuerung nach RDO-Beton 09 ist die statische Spaltzugfestigkeit an der unteren und oberen Bohrkernscheibe entsprechend der Vorgaben der AL Sp-Beton zu bestimmen. Aufgrund der unzureichenden Kenntnis der Präzision dieses Prüfverfahrens wurden, basierend auf dem Entwurf des FGSV-Merkblatts zur statistischen Auswertung von Prüfergebnissen, mit einem breit aufgestellten Ringversuch die statistischen Kennwerte an Labor- und Bestandsbetonen unter Vergleich- und Wiederholbedingungen ermittelt. Zur möglichst guten statistischen Absicherung nahmen an dem Ringversuch dreizehn erfahrene Prüfstellen teil, die vorab einem Audit unterzogen wurden. Zur Abdeckung des vielschichtigen Einsatzes des Prüfverfahrens erfolgte der Ringversuch an acht Prüflosen, die sowohl die Erst-/ Eignungsprüfung und Übereinstimmungskontrolle bei Neubaumaßnahmen, als auch die Restsubstanzbewertung von Betonfahrbahnplatten berücksichtigen. Zur Bewertung des Materialeinflusses wurde zusätzlich ein Prüflos mit Labormörtel untersucht.
Die Probenvorbereitung erfolgte zentral an der BAM. Zur Sicherstellung einheitlicher Prüfbedingungen bei den Prüfstellen wurde zusätzlich eine detaillierte Standardarbeitsanweisung erarbeitet, die partiell bereits Eingang in das Normenwerk gefunden hat. Bei der Plausibilitätsprüfung aller prüflosspezifischen Einzelwerte der Spaltzug- und Druckfestigkeit wurden vereinzelt sowohl Ausführungsfehler als auch Übertragungs- und Tippfehler festgestellt. Der sich anschließende Lilliefors-Test zeigt, dass die ermittelten Einzelwerte bis auf wenige Aus-nahmen normalverteilt sind und damit die Voraussetzungen für die statistische Auswertung gegeben sind.
Mittels grafischer Darstellung der Mandel’s h- und k-Werte wurden die Auffälligkeiten hinsichtlich der Mittelwerte und Varianzen prüflosspezifisch für die einzelnen Prüfstellen visualisiert und anschließend einige von ihnen mittels Grubbs- und Cochran-Test als Ausreißer identifiziert. Nach Ausreißerelimination wurde mit dem klassischen Verfahren bei der Spaltzugfestigkeit der geringste Variationskoeffizient unter Vergleich- und Wiederholbedingungen bei der Erst-/Eignungsprüfung mit 6,2 und 6,4 Prozent ermittelt. Bei einer Verminderung des Materialeinflusses durch die Verwendung eines Labormörtels verbessern sich die statistischen Kennwerte auf 4,5 und 5,3 Prozent. Mit 8,2 und 9,5 Prozent beziehungsweise 8,6 und 9,5 Prozent werden bei der Restsubstanzbewertung von Wasch- und Unterbetonen die höchsten Werte bestimmt.
Das robuste Auswerteverfahren (ohne Eliminierung der Ausreißer) nach dem Entwurf des FGSV-Merkblatts zur statistischen Auswertung von Prüfergebnissen erwies sich in der Form als ungeeignet und bedurfte einer Überarbeitung. Bezüglich der vergleichend mit klassischen und robusten Verfahren gewonnenen Kennwerte ist festzustellen, dass bei sehr homogenen Messergebnissen eines Prüfloses beide Verfahren nahezu die gleichen statistischen Kennwerte liefern. Bei der Eliminierung von Ausreißern sind die Ergebnisse des robusten Verfahrens in der Regel etwas größer als die des klassischen Verfahrens.
Die begleitenden vertiefenden Untersuchungen bei der Spaltzugprüfung mit innovativen Prüftechniken lieferten wertvolle Erkenntnisse zur Bewertung der Prüfeinflüsse.
It is important to protect critical buildings (shopping centres, government buildings and embassies), infrastructure and utilities, train and underground stations against being damaged, destroyed or disrupted by deliberate acts of terrorism, criminal activity and malicious behaviour. Normal regulations and building guidelines do not generally take into account these threats. The introduction of regulations or guidelines should support the resilience of the buildings and infrastructure against explosive incidents. In order to protect the infrastructure, methods are required to quantify the resistance of structural elements against explosive loading and to assess the hazards resulting from failure of an element. The applicable state-of-the-art techniques may be either experimental or numerical methods, or a combination of both. Therefore, the thematic group (TG) on the resistance of structures to explosion effects was formed in order to bring the required expertise together, make it commonly available and to find and define harmonised methods and solutions which can be provided to the decision-makers responsible for critical infrastructure protection. This first report of the TG gives a comprehensive summary of the existing methods which can be used to analyse and test the resistance of glazing and windows under blast-loading conditions. Within this context, the experimental methods of testing using high explosives and testing using blast simulators called shock tubes is presented and explained. In addition, the potential of numerical simulations is highlighted in terms of their applicability to the different glass materials. A short, comprehensive theoretical background is given for each method. Based on this, each method is described with its requirements, realisation and the related measurement techniques. Furthermore, an interpretation of the measurements is highlighted. For the numerical simulations, the basic discretisation and calculations schemes are presented in combination with the available constitutive material descriptions for the different significant materials. Finally the chances for verification and validation of the numerical results are presented. Hence the report builds the basis for an actual evaluation of the different test methods and their applicability to certain problems, and provides helpful information for critical infrastructure stakeholders, owners and operators considering the structural resistance of the infrastructure to the effects of explosion in a comprehensive document.
Remediation of Cracks Formed in Grouted Connections of Offshore Energy Structures under Static Loads
(2018)
The future energy demand necessitates the exploration of all potential energy sources both onshore and offshore. Global trend has shifted towards offshore energy, which can be obtained from either carbon intensive or renewable options, hence requiring structures such as rigs, platforms, and monopiles. Most of these structures adopt easily installable construction techniques, where lower foundation need to be connected with the super structure by mean of grouted composite joints. Generally, these composite connections have exterior sleeve, interior pile and infill grout. Being located in remote offshore conditions, connections can experience considerable adverse loading during their lifetimes. Degradations were reported inside similar connections, which were installed in last three decades. Besides, grouting in the offshore sites may often be proven difficult, which eventually leads to reduced capacity of connections in the long run. Thus, repair and rehabilitation of such connections should be planned ahead to minimize operational delays and costs in the future. This study aims at characterizing the nature of crack generation in grouted connections and thereby identifying the potential of repair using suitable repair material. Scaled grouted joints were manufactured using a novel mold, and connections were loaded under static load to visualize the main failure pattern. The failure mechanism and loading capacity are found compatible to previous results from earlier literature. Grouted connection was then repaired using cementitious injectable grout. The effectiveness of the repair system is also discussed.
It is important to protect critical buildings (shopping centres, government buildings and embassies), infrastructure and utilities, train and underground stations from being damaged, destroyed or disrupted by deliberate acts of terrorism, criminal activity and malicious behaviour. Normal regulations and building guidelines do not generally take into account these threats. The introduction of appropriate regulations or guidelines, where deemed necessary, should enhance the resilience of buildings and infrastructures against explosion incidents. In order to protect the built infrastructure, testing methods are required which can answer the question whether certain building elements can withstand certain loading conditions created by an explosive event. The applicable state-of-the-art techniques may include either experimental or numerical methods, or a combination of both. Therefore, the thematic group (TG) on the resistance of structures to explosion effects was formed in order to bring the required expertise together, to make it commonly available and to find and define harmonised methods and solutions which can be provided to the decision-makers responsible for critical infrastructure protection. The TG described in a fist report JPC87202 the physical phenomena which have to be understood in order to ensure a proper testing of the elements and a correct interpretation of the results. In a second step, the differences between the existing standards for testing blast-resistant glazing and windows have been derived, and a basis for fundamental recommendations for the future development of the suite of European standards has been addressed JRC94930. Based on the prior findings, this report now formulates the proper enhancements of the existing standards in terms of actual recommendations for the improvement of the test standards.
The determination of the blast protection level of civil engineering buildings components
against explosive effects represents a topic of crucial importance, in current practice. However, some key aspects of blast resistant structures design have been only marginally considered in the last decade, and currently still require appropriate regulations. This is especially true in the case of windows and facades, where the intrinsic material brittleness is the major influencing parameter for blast-resistant assemblies. While blast assessment of buildings and systems is usually achieved by means of experimental investigations, as well as numerical simulations, general regulations and guidelines are currently missing.
In this regard, the European Reference Network for Critical Infrastructure Protection (ERNCIP) Thematic Group “Resistance of Structures to Explosion Effects” attempts to develop guidelines and recommendations aimed to harmonise test procedures in experimental testing of glass windows under blast, as well as standardized approaches for their vulnerability assessment via numerical modelling. In this paper, major Thematic Group outcomes and next challenges are briefly summarized.
The bond between polymer fibers and the surrounding cementitious matrix is essential for the development of concrete reinforcement. The single fiber pull-out test (SFPT) is the standard characterization technique for testing the bond strength. However, the different phases of debonding cannot be distinguished by the SFPT. This study investigates the debonding of different polymer fibers from the surrounding cementitious matrix with a modified SFPT and proposes methods to change the SFPT setup to generate more valuable information on the debonding mechanism. The SFPT was equipped with linear variable differential transformers (LVDT), digital image correlation (DIC) and acoustic emission (AE) analysis. The results demonstrate that the modified SFPT allows a better understanding of the different phases of debonding during fiber pull-out. Furthermore, bond strength values calculated by different methods reveal that the chemical bond of the investigated polymers is not different as reported by previous studies. Deformation measurements performed using LVDTs and DIC are suitable measuring techniques to characterize the debonding mechanism in SFPT. A correlation between recorded AE and debonding phases was not found.
Grouted connections are intensively used in offshore rigs, platforms as well as jacket and monopile offshore wind turbine structures. Being located in remote offshore conditions, these connections can experience considerable adverse loading during their lifetimes. Degradation was reported inside similar connections, which were installed in the last three decades. Grouting in the offshore sites may often be proven difficult, which eventually leads to reduced load-bearing capacity of connections in the long run. Thus, repair and rehabilitation of such connections should be planned ahead to minimize operational delays and costs. In this study, scaled grouted connections were manufactured using a novel mould, whose integrity were monitored using digital image correlation (DIC). The connections were loaded under static load to visualize the main failure pattern using distributed fibre optic sensors and acoustic emission (AE) analysis. Grouted connections were then repaired using a cementitious injectable grout. The effectiveness of the grout injection was monitored using dye penetration technique. Finally, specimens are reloaded to identify the potential of such repair for grouted connections.
Waste sludge, a solid recovered from wastewater of photovoltaic-industries, composes of agglomerates of nano-particles like SiO2 and CaCO3. This sludge deflocculates in aqueous solutions into nano-particles smaller than 1 µm. Thus, this sludge constitutes a potentially hazardous waste when it is improperly disposed. Due to its high content of amorphous SiO2, this sludge has a potential use as supplementary cementitious material (SCM) in concrete. In this study the main properties of three different samples of photovoltaic's silica-rich waste sludge (nSS) were physically and chemically characterized. The characterization techniques included: scanning electron microscopy (SEM), X-ray energy dispersive spectroscopy (EDS), X-ray diffraction (XRD), nitrogen physical adsorption isotherm (BET method), density by Helium pycnometry, particle size distribution determined by laser light scattering (LLS) and zeta-potential measurements by dynamic light scattering (DLS). In addition, a dispersability study was performed to design stable slurries to be used as liquid additives for the concrete production on site. The effects on the hydration kinetics of cement pastes by the incorporation of nSS in the designed slurries were determined using an isothermal calorimeter. A compressive strength test of standard mortars with 7% of cement replacement was performed to determine the pozzolanic activity of the waste nano-silica sludge. Finally, the hardened system was fully characterized to determine the phase composition. The results demonstrate that the nSS can be utilized as SCM to replace portion of cement in mortars, thereby decreasing the CO2 footprint and the environmental impact of concrete.