Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (32)
- Zeitschriftenartikel (15)
- Vortrag (12)
- Forschungsbericht (6)
- Beitrag zu einem Sammelband (1)
Schlagworte
- Acoustic emission analysis (6)
- Cracks (5)
- Durability (5)
- Digital image correlation (4)
- Grout (4)
- Grouted connection (4)
- Nano-silica (4)
- Spaltzugfestigkeit (4)
- Tensile strength (4)
- Concrete (3)
Organisationseinheit der BAM
- 7 Bauwerkssicherheit (27)
- 7.4 Baustofftechnologie (25)
- 7.2 Ingenieurbau (12)
- 7.1 Baustoffe (8)
- 8 Zerstörungsfreie Prüfung (8)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (5)
- 8.6 Faseroptische Sensorik (4)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (3)
- 2 Prozess- und Anlagensicherheit (2)
- 2.4 Prüfung und Bewertung von Explosivstoffen/Pyrotechnik (2)
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (12)
Effects of amorphous nano-silica additions on mechanical and durability performance of SCC mixtures
(2012)
In the recent years the application of nanotechnology in building materials has increased
exponentially. One of the most referred and used nano-materials is amorphous silica with
particles size in the nano-range, even though its application and effect in concrete has not been
fully understood yet. It has been reported that nano-silica (nS) addition increases the
compressive strength and reduces the overall permeability of hardened concrete due to the
pozzolanic properties which are resulting in finer hydrated phases (C-S-H gel) and densified
microstructure (nano-filler and anti leaching effects). These effects enhance the durability of
concrete structures such as bridges, quays or off-shore oil facilities in marine environments.
In this study two different types of nano-silica were applied in self-compacting concrete (SCC),
both having similar particle size distributions (PSD) but produced in two different processes
(fumed powder silica and precipitated silica in colloidal suspension). The influence of nanosilica
on SCC was investigated with respect to the properties of concrete in the fresh state
(workability) and hardened state (mechanical properties and durability). Additionally, the
densification of microstructure of the hardened concrete was verified by SEM and EDS analyses.
The obtained results demonstrate that an efficient use of nano-silica in SCC can improve its
mechanical properties and durability. Considering the reactivity of the two nano-silica studied,
colloidal type shown more reactivity at early age, which influenced all the final SCC properties.
This paper presents experimental investigations and analyses on the early-age-behavior of zero-slump concrete, such as compaction behavior and green-strength. First, the influence of the granulometric properties of the fines is discussed in detail. For this purpose, the early-age behavior of two different fines (quartz flour and fly ash) is investigated by means of the intensive compaction test (IC-test). The tests on the influence of the fines focus on effects caused by differences in the particle shape and the use of a plasticizing admixture. The conducted tests on the compaction behavior of the fines and their corresponding green-strength are extended to continuously graded granular mixes. Here, the influence of optimized particle packing on the early-age behavior is presented and a comparison on the basis of the aforementioned quartz flour and fly ash is made. In this consideration, experimental investigations on the early-age behavior of a zero-slump concrete mix and possible effects on the hardened concrete properties are included.
This paper addresses the characterization of six different amorphous silica samples with respect to their application in cement paste. Different mixes are compared and analyzed using the mini spread-flow test. Also the granular properties, different void fraction states of packing and distribution moduli q are analyzed and compared using a mix design tool. A deformation coefficient is derived from the spread-flow test, which correlates with the value of specific surface area computed from the particle size distribution, and intrinsic density of the samples. Finally, the thickness of a constant water layer of 25 nm around the particles is computed at the onset of flowing. The granular analysis demonstrated that it is possible to decrease the water demand of the cement paste when nanoparticles are added and the resulting grading follows the modified Andreasen and Andersen curve (q = 0.5), and the concentration of nano silica is less than 5% bwoc.
It is important to protect critical buildings (shopping centres, government buildings and embassies), infrastructure and utilities, train and underground stations against being damaged, destroyed or disrupted by deliberate acts of terrorism, criminal activity and malicious behaviour. Normal regulations and building guidelines do not generally take into account these threats. The introduction of regulations or guidelines should support the resilience of the buildings and infrastructure against explosive incidents. In order to protect the infrastructure, methods are required to quantify the resistance of structural elements against explosive loading and to assess the hazards resulting from failure of an element. The applicable state-of-the-art techniques may be either experimental or numerical methods, or a combination of both. Therefore, the thematic group (TG) on the resistance of structures to explosion effects was formed in order to bring the required expertise together, make it commonly available and to find and define harmonised methods and solutions which can be provided to the decision-makers responsible for critical infrastructure protection. This first report of the TG gives a comprehensive summary of the existing methods which can be used to analyse and test the resistance of glazing and windows under blast-loading conditions. Within this context, the experimental methods of testing using high explosives and testing using blast simulators called shock tubes is presented and explained. In addition, the potential of numerical simulations is highlighted in terms of their applicability to the different glass materials. A short, comprehensive theoretical background is given for each method. Based on this, each method is described with its requirements, realisation and the related measurement techniques. Furthermore, an interpretation of the measurements is highlighted. For the numerical simulations, the basic discretisation and calculations schemes are presented in combination with the available constitutive material descriptions for the different significant materials. Finally the chances for verification and validation of the numerical results are presented. Hence the report builds the basis for an actual evaluation of the different test methods and their applicability to certain problems, and provides helpful information for critical infrastructure stakeholders, owners and operators considering the structural resistance of the infrastructure to the effects of explosion in a comprehensive document.
Für die rechnerische Dimensionierung der Betondecken im Oberbau von Verkehrsflächen für den Neubau sowie die Erneuerung nach RDO Beton 09 ist die statische Spaltzugfestigkeit an der unteren bzw. unteren und oberen Scheibe des Betonzylinders bzw. Bohrkerns entsprechend der Vorgaben der AL Sp-Beton zu bestimmen. Aufgrund der unzureichenden Kenntnis der Präzision dieses Prüfverfahrens wurden mit einem breit aufgestellten Ringversuch die statistischen Kennwerte an Labor- und Bestandsbetonen unter Vergleich- und Wiederholbedingungen auf der Grundlage des „Merkblatts über die statistische Auswertung von Prüfergebnissen" ermittelt. Für eine möglichst gute statistische Absicherung nahmen an dem Ringversuch 13 erfahrene Prüfstellen teil. Zur Abdeckung des vielschichtigen Einsatzes des Prüfverfahrens erfolgte der Ringversuch an acht Prüflosen. Dabei berücksichtigen einerseits die Prüf lose 1 und 2 mit den im Transportbetonwerk hergestellten Betonzylindern die Erst-/Eignungsprüfung und das darauf aufbauende Prüflos 3 mit Bohrkernen aus einer im Feldversuch hergestellten Fahrbahnplatte mit gleicher Betonrezeptur die Übereinstimmungskontrolle bei Neubaumaßnahmen. Andererseits findet der Einsatz des Prüfverfahrens bei der Restsubstanzbewertung von Betonfahrbahnplatten bei den Prüflosen 4 bis 7 mit den Bohrkernen aus vier in Waschbetonbauweise ausgeführten Fahrbahnplatten Berücksichtigung. Das zusätzlich aufgenommene Prüflos 8 mit einem Labormörtel dient der Herausarbeitung des Materialeinflusses auf die Präzision der Spaltzugfestigkeitsprüfung. Zusammenfassend kann festgestellt werden, dass die Präzision der in der AL SP-Beton beschriebenen Spaltzugfestigkeitsprüfung mit einem Variationskoeffizienten von weniger als 10 % unter Wiederhol- und Vergleichbedingungen hinreichend genau ist. Der geringe Unterschied zwischen den Variationskoeffizienten unter Wiederhol- und Vergleichbedingungen lässt zusätzlich den Schluss zu, dass der Einfluss des unterschiedlichen Personals und der verschiedenartigen Prüftechniken bei den einzelnen Prüfstellen relativ gering ist. Die im Rahmen des Ringversuchs gewonnenen Erkenntnisse haben bereits partiell Eingang in die Normung gefunden.
Waste sludge, a solid recovered from wastewater of photovoltaic-industries, composes of agglomerates of nano-particles like SiO2 and CaCO3. This sludge deflocculates in aqueous solutions into nano-particles smaller than 1 µm. Thus, this sludge constitutes a potentially hazardous waste when it is improperly disposed. Due to its high content of amorphous SiO2, this sludge has a potential use as supplementary cementitious material (SCM) in concrete. In this study the main properties of three different samples of photovoltaic's silica-rich waste sludge (nSS) were physically and chemically characterized. The characterization techniques included: scanning electron microscopy (SEM), X-ray energy dispersive spectroscopy (EDS), X-ray diffraction (XRD), nitrogen physical adsorption isotherm (BET method), density by Helium pycnometry, particle size distribution determined by laser light scattering (LLS) and zeta-potential measurements by dynamic light scattering (DLS). In addition, a dispersability study was performed to design stable slurries to be used as liquid additives for the concrete production on site. The effects on the hydration kinetics of cement pastes by the incorporation of nSS in the designed slurries were determined using an isothermal calorimeter. A compressive strength test of standard mortars with 7% of cement replacement was performed to determine the pozzolanic activity of the waste nano-silica sludge. Finally, the hardened system was fully characterized to determine the phase composition. The results demonstrate that the nSS can be utilized as SCM to replace portion of cement in mortars, thereby decreasing the CO2 footprint and the environmental impact of concrete.
The high demand for sustainable and durable building materials requires profound knowledge on the material properties. In this respect, the phenomena occurring at nano-level are of crucial importance for the design of new building materials. Therefore, all around the world, increasing amounts of funding are being directed to research projects dealing with material properties on nano-level, which is claimed to have tremendous potential for the future. One of the most referred to and used cementitious nano-material is amorphous silica with a particle size in the nano-range, even though its application and effects on concrete have not been fully understood yet. Olivine (Mg,Fe)2Si04 is the fastest weathering siiicate mineral dissolving easily in acid. Düring dissolution in acid the metallic ions (Mg2+,Fe2+) are replaced by H+, yielding Si(OH)4 monomers and metallic ions in solution. After cleaning treatments an amorphous nano-silica is obtained. The produced olivine nano-silica (OnS) has a specific surface area between 100 and 400 m2/g, the size of the primary particles, which are agglomerated in Clusters, ranges from 10 to 25 nm and the impurity content is below 5 % IV. Literature related with the application of OnS in cement based materials is scarce; only one research work performed by Justnes and Ostnor 121 is available. Thus, the effect of adding OnS in cement based Systems has been not studied. Based on this, the present research aims on elucidating the effects of OnS in the fresh and hardened state of cement pastes and mortars.
Die Forderung, für repräsentative Bauwerke wie Botschaften und Flughäfen auch außergewöhnliche Lasten aus Explosion zu berücksichtigen, wurde in jüngerer Vergangenheit zunehmend gestellt. Das aufgrund dieser Lasten zu erwartende Schadensausmaß kann durch den Einsatz von energiedissipierenden Schutzbauteilen in der Fassadenbefestigung begrenzt werden. Die Dissipation der Explosionsenergie in den Schutzbauteilen kann beispielsweise über ein Crashmaterial erfolgen. In diesem Aufsatz werden Untersuchungen an zementgebundenen Materialien, die diesem Zweck dienen sollen, vorgestellt. Der Einfluss unterschiedlicher Zusätze auf die für ein Crashmaterial maßgebenden Eigenschaften wird in einer Parameterstudie untersucht. Als besonders geeignet wird ein Material identifiziert, bei dem die Zugabe eines Gasbildners das Matrixgefüge im Hinblick auf das gewünschte Kraft-Verformungs-Verhalten positiv verändert. Dynamische Versuche mit diesem Material geben Aufschluss über dessen Komprimierungsverhalten bei hohen Stauchraten.-----------------------------------------------------------------------------------------------------------------------------------------------
In the past few years public awareness of the need to protect structures against blast effects has risen. Energy dissipating protective components placed at the façade connectors allow protecting people in the building as well as the primary building structure from damage due to blast loads. One possibility to dissipate the blast energy is using protective components with crash material. This paper presents tests on cementitious crash materials studying the effect of different additives to the compression-behavior of the material. Additional experiments enable analyzing the material behavior under static and dynamic test conditions.
In this study two different types of nano-silica (nS) were applied in self-compacting concrete (SCC), both having similar particle size distributions (PSD), but produced through two different processes: fumed powder silica and precipitated silica in colloidal suspension. The influence of nano-silica on SCC was investigated with respect to the properties of concrete in fresh (workability) and hardened state (mechanical properties and durability). Additionally, the densification of the microstructure of the hardened concrete was verified by SEM and EDS analyses. The obtained results demonstrate that nano-silica efficiently used in SCC can improve its mechanical properties and durability. Considering the reactivity of the two applied nano-silicas, the colloidal type showed a higher reactivity at early age, which influenced the final SCC properties.
Design of a cementitious coating system for corrosion protection: Phase 1 binder materials selection
(2014)
This paper presents the first results of an ongoing research project on the development of a cementitious thin layer coating system with high resistance against chloride penetration and carbonation. It is intended to display the decision process used for selecting raw materials as well as the conclusions based on test results and theoretical deliberations. In this phase, only the influence of the binder materials was analyzed concerning mechanical properties. The system should enhance the durability of new and old concrete structures exposed to aggressive environments, be based on market available materials and fulfill the requirements of the German guideline for concrete repair (Rili-SIB).
Für die rechnerische Dimensionierung der Betondecken im Oberbau von Verkehrsflächen für den Neubau sowie die Erneuerung nach RDO-Beton 09 ist die statische Spaltzugfestigkeit an der unteren bzw. unteren und oberen Scheibe des Betonzylinders bzw. Bohrkerns entsprechend der Vorgaben der AL Sp-Beton zu bestimmen. Aufgrund der unzureichenden Kenntnis der Präzision dieses Prüfverfahrens wurden mit einem breit aufgestellten Ringversuch die statistischen Kennwerte an Labor- und Bestandsbetonen unter Vergleich- und Wiederholbedingungen auf der Grundlage des FGSV-Merkblatts über die statistische Auswertung von Prüfergebnissen ermittelt. Für eine möglichst gute statistische Absicherung nahmen an dem Ringversuch dreizehn erfahrene Prüfstellen teil. Zur Abdeckung des vielschichtigen Einsatzes des Prüfverfahrens erfolgte der Ringversuch an acht Prüflosen. Dabei berücksichtigen einerseits die Prüflose 1 und 2 mit den im Transportbetonwerk hergestellten Betonzylindern die Erst-/Eignungsprüfung und das darauf aufbauende Prüflos 3 mit Bohrkernen aus einer im Feldversuch hergestellten Fahrbahnplatte mit gleicher Betonrezeptur die Übereinstimmungskontrolle bei Neubaumaßnahmen. Andererseits findet der Einsatz des Prüfverfahrens bei der Restsubstanzbewertung von Betonfahrbahnplatten bei den Prüflosen 4 bis 7 mit den Bohrkernen aus vier in Waschbetonbauweise ausgeführten Fahrbahnplatten Berücksichtigung. Das zusätzlich aufgenommene Prüflos 8 mit einem Labormörtel dient der Herausarbeitung des Materialeinflusses auf die Präzision der Spaltzugfestigkeitsprüfung.
Zusammenfassend kann festgestellt werden, dass die Präzision der in der AL SP-Beton beschriebenen Spaltzugfestigkeitsprüfung mit einem Variationskoeffizienten von weniger als 10 % unter Wiederhol- und Vergleichsbedingungen hinreichend genau ist. Der geringe Unterschied zwischen den Variationskoeffizienten unter Wiederhol- und Vergleichsbedingungen lässt zusätzlich den Schluss zu, dass der Einfluss des unterschiedlichen Personals und der verschiedenartigen Prüftechniken bei den einzelnen Prüfstellen relativ gering ist. Die im Rahmen des Ringversuchs gewonnenen Erkenntnisse haben bereits partiell Eingang in die Normung gefunden.
Im Rahmen einer Bachelorarbeit und in Kooperation mit der Bundesanstalt für Materialforschung und -prüfung (BAM) wurden die eintretenden Schädigungsprozesse während des Spaltzugversuche mittels innovativer Prüfverfahren untersucht. Ziel war es, in Untersuchungen Erkenntnisse über das Versagensverhalten unter statischer und dynamischer Spaltzugbeanspruchung bei der Variation verschiedener Einflussfaktoren zu gewinnen. Hierfür wurde die Aussagekraft innerer und äußerer Schädigungsindikatoren zur Charakterisierung der auftretenden Bruchmechanismen analysiert.
It is important to protect critical buildings (shopping centres, government buildings and embassies), infrastructure and utilities, train and underground stations against being damaged, destroyed or disrupted by deliberate acts of terrorism, criminal activity and malicious behaviour. Normal regulations and building guidelines do not generally take into account these threats. The introduction of appropriate regulations or guidelines, where deemed necessary, should enhance the resilience of buildings and infrastructure against explosion incidents. In order to protect the built infrastructure, methods are required to quantify the resistance of structural components against explosive loading and to assess the hazards resulting from the failure of an element. The applicable state-of-the-art techniques may include either experimental or numerical methods, or a combination of both. Therefore, the thematic group (TG) on the resistance of structures to explosion effects was formed in order to bring the required expertise together, make it commonly available and to find and define harmonised methods and solutions which can be provided to the decision-makers responsible for critical infrastructure protection. This report discusses the differences between the existing standards for testing blast-resistant glazing and windows and it presents basic recommendations for the future development of the suite of European standards in this area.
It is important to protect critical buildings (shopping centres, government buildings and embassies), infrastructure and utilities, train and underground stations against being damaged, destroyed or disrupted by deliberate acts of terrorism, criminal activity and malicious behaviour. Normal regulations and building guidelines do not generally take into account these threats. The introduction of appropriate regulations or guidelines, where deemed necessary, should, enhance the resilience of buildings and infrastructure against explosion incidents. In order to protect the built infrastructure, methods are required to quantify the resistance of structural components against explosive loading and to assess the hazards resulting from the failure of an element. The applicable state-of-the-art techniques may include either experimental or numerical methods, or a combination of both. Therefore, the thematic group (TG) on the resistance of structures to explosion effects was formed in order to bring the required expertise together, make it commonly available and to find and define harmonised methods and solutions which can be provided to the decision-makers responsible for critical infrastructure protection. The current report summarizes existing best practices for the numerical finite element modelling of blast loading, including the important topics of domain discretisation, implicit/explicit formulation, Lagrangian/Eulerian solvers, the mathematical description of the material behaviour etc. Furthermore recommendations for the modelling of laminated glass elements are formulated and knowledge gaps in this application area are pointed out. Hence the report builds the basis for an actual evaluation of the different numerical methods, their suitability to certain problems, and their capability to support/complement the experimental testing of glass components. It thus provides helpful information to design architects and engineers, and more generally to critical infrastructure stakeholders, responsible for the structural integrity and security of the infrastructure in case of an explosion.
Reinforced concrete buildings are frequently damaged by cracks, spalling and corroded
reinforcement bars. The present article focuses on the damage analysis of one of the first
buildings in Berlin that was constructed using reinforced lightweight concrete, which makes it
historically important. The compressive strength, carbonation depth, location and diameter of
reinforcement bars as well as moisture and salt profiles were determined. The carbonationinduced corrosion of the reinforcement bars represented the main damage of the building.
Certified repair mortars with lightweight aggregates (LWA) do not exist on the German
market. Therefore, an appropriate repair mortar was developed in accordance with DIN EN
1504 and the German guideline for the repair and protection of concrete structures (RL-SIB).
On the one hand, historic preservation requirements, such as: colour of the mortar,
possibilities of surface patterning, maximum preservation of the original substance and
reversibility of any Intervention must be met. On the other hand, technical requirements of the
relevant Standards must be achieved. The developed mix was designed to resist the identified
causes of deterioration. Thermal strains within the repair mortar and between the repair
mortar and the Substrate influence the crack formation and thus the durability. Therefore,
special attention was paid to the bonding and shrinking behaviour of the concrete repair
System. By using polymers, both hardened mortar properties and durability were influenced
positively.
Entwicklung eines PCC-Leichtmörtels zur Instandsetzung einer denkmalgeschützten Sichtbetonfassade
(2015)
Der Schutz und Erhalt der Originalsubstanz stehen im Mittelpunkt jeglicher denkmalpflegerischer Instandhaltungsmaßnahmen. Das äußere Erscheinungsbild spielt hierbei - im Gegensatz zur klassischen Betoninstandsetzung - eine größere Rolle. Nichtsdestotrotz dürfen die technischen Belange auch hier nicht außer Acht gelassen werden. Die Ermittlung des Ist- und Sollzustands stellt die Grundlage einer dauerhaften Instandsetzung dar. Der vorliegende Beitrag zeigt Schäden und Schadensursachen an einem denkmalgeschützten Gebäude in Leichtbetonbauweise auf. Das Bauwerk wurde hinsichtlich seines Schädigungsgrads, -umfangs und der maßgeblichen Schadensursachen untersucht. Im Rahmen dieser Untersuchungen wurden gehäuft Risse, Abplatzungen und Bewehrungskorrosion festgestellt. Die durch eine Brettschalung strukturierte Sichtbetonfassade soll im Zuge der Instandsetzungsmaßnahme möglichst originalgetreu wiederhergestellt werden.
Bei der Auswahl von geeigneten Instandsetzungsmethoden und -produkten konnte aufgrund fehlender Normen und Richtlinien für die Instandsetzung von denkmalgeschützten Leichtbetonbauten nicht auf bereits existierende Produkte und Methoden zurückgegriffen werden. Daher wurde in Anlehnung an die Richtlinie "Schutz und Instandsetzung von Betonbauteilen" (RL SIB) des DAfStB eine polymermodifizierte Betonergänzungsmasse mit leichter Gesteinskörnung entwickelt. Ausgehend von der Hauptschadensursache, der karbonatisierungsinduzierten Bewehrungskorrosion, wurden erforderliche Eigenschaften der Betonergänzungsmasse in enger Absprache mit der zuständigen Denkmalschutzbehörde und dem involvierten Fachplaner abgestimmt. Neben den grundlegenden mechanischen Eigenschaften spielen in diesem Anwendungsfall spezielle Eigenschaften wie z.B. farbliehe Anpassung der Betonergänzungsmasse, Möglichkeit der Oberflächenstrukturierung, Zeitfenster der Verarbeitbarkeit sowie die Modellierbarkeit eine wichtige Rolle. Der entwickelte PCC-Leichtmörtel berücksichtigt dabei auch den Einfluss einer geringen Schwind- und Quellneigung der Betonergänzungsmasse um Delaminierung infolge unterschiedlicher Längenänderungen zu vermeiden und somit eine dauerhafte Instandsetzung zu gewährleisten. Weiterhin wurde das Verbundverhalten des entwickelten PCCL Leichtmörtels für unterschiedliche Schichtaufbauten untersucht.
The determination of the blast protection level of laminated glass windows and facades is of crucial importance, and it is normally done by using experimental investigations. In recent years numerical methods have become much more powerful also with respect to this kind of application. This report attempts to give a first idea of a possible standardisation concerning such numerical simulations. Attention is drawn to the representation of the blast loading and of the behaviour of the material of the mentioned products, to the geometrical meshing, as well as to the modelling of the connections of the glass components to the main structure. The need to validate the numerical models against reliable experimental data, some of which are indicated, is underlined.
It is important to protect critical buildings (shopping centres, government buildings and embassies), infrastructure and utilities, train and underground stations from being damaged, destroyed or disrupted by deliberate acts of terrorism, criminal activity and malicious behaviour. Normal regulations and building guidelines do not generally take into account these threats. The introduction of appropriate regulations or guidelines, where deemed necessary, should enhance the resilience of buildings and infrastructures against explosion incidents. In order to protect the built infrastructure, testing methods are required which can answer the question whether certain building elements can withstand certain loading conditions created by an explosive event. The applicable state-of-the-art techniques may include either experimental or numerical methods, or a combination of both. Therefore, the thematic group (TG) on the resistance of structures to explosion effects was formed in order to bring the required expertise together, to make it commonly available and to find and define harmonised methods and solutions which can be provided to the decision-makers responsible for critical infrastructure protection. The TG described in a fist report JPC87202 the physical phenomena which have to be understood in order to ensure a proper testing of the elements and a correct interpretation of the results. In a second step, the differences between the existing standards for testing blast-resistant glazing and windows have been derived, and a basis for fundamental recommendations for the future development of the suite of European standards has been addressed JRC94930. Based on the prior findings, this report now formulates the proper enhancements of the existing standards in terms of actual recommendations for the improvement of the test standards.
До 1970-х годов производители бетона и ЖБИ определяли свой продукт исключительно как долговечный строительный материал. В последующие годы инженеры-строители ввели такие термины как устойчивость и экспозиция. Современные бетонные технологии учитывают, что определенные строительные материалы (в частности, бетоны) обладают высокой устойчивостью к замораживанию-оттаиванию и расслоению.
Hochfeste und ultrahochfeste Stahlfaserbetone eignen sich aufgrund ihrer Eigenschaften für den Einsatz bei extremen mechanischen Beanspruchungen. Das für diesen Einsatz erforderliche duktile Bruchverhalten unter Zugbeanspruchung wird ausschließlich durch die Zugabe von geeigneten Stahlfasern und deren Wirkung in der Zementsteinmatrix erreicht. Für eine gezielte stoffliche Optimierung des Systems sind fundierte Kenntnisse zur Wirkungsweise der Stahlfasern notwendig, die bei bisherigen Untersuchungen lediglich auf Basis von klassischen Messverfahren zerstörender Prüfungen gewonnen wurden. Durch das Einbeziehen von Methoden der zerstörungsfreien Materialcharakterisierung können das Bruchverhalten hochfester und ultrahochfester Stahlfaserbetone orts- und zeitaufgelöst untersucht und die einzelnen Phasen des Schädigungsprozesses identifiziert werden. Anhand der vorliegenden Ergebnisse von Zugversuchen eines ultrahochfesten Stahlfaserbetons wird der kombinierte Einsatz von Methoden der zerstörungsfreien Materialprüfung gezeigt und deren Anwendbarkeit in der Analyse des Bruchverhaltens diskutiert. Das Hauptaugenmerk liegt dabei auf der Charakterisierung der ausschlaggebenden Versagensmodi unter Zugbelastung durch die einzelnen Verfahren und dem Vergleich zu klassischen Messmethoden (z. B. Extensometer). Die Zugversuche wurden dazu parallel durch optische Verformungsanalyse mittels Bildkorrelation (DIC), Schallemissionsanalyse (SEA) und 3-D-Computertomografie (CT) begleitet.
Anhand der aus Biegeversuchen vorliegenden Ergebnisse wird der Einsatz unterschiedlicher Methoden der zerstörungsfreien Materialprüfung gezeigt und deren Anwendbarkeit für die Analyse des Verformungsverhaltens von Stahlbetonbalken diskutiert. Hierzu wurde das Verformungsverhalten eines Stahlbetonbalken (L = 2,75 m) in einem 4-Punkt-Biegeversuch untersucht. Das Hauptaugenmerk liegt dabei auf der Charakterisierung der ausschlaggebenden Versagensmodi durch die einzelnen zerstörungsfreien Prüfverfahren und der Vergleich zu klassischen Messmethoden (z.B. Verformungsmessung mittels induktiver Wegaufnehmer). Die Biegeversuche wurden dazu durch Schallemissionsanalyse (SEA) und optische Verformungsanalyse mittels Bildkorrelation (DIC) begleitet.
The interaction mechanism of ultrasonic waves with surface-breaking cracks in reinforced concrete has been studied. For this, a detailed numerical analysis of the medium was first conducted using the spectral finite element method. Subsequently, measurements were conducted on a reinforced beam sample before and after mechanical-load-induced cracking. It was concluded that for the considered configuration, waves passing through the cracks dominated the tip-diffracted ones. In addition, substantial changes in the travel time and amplitude of the signals were observed when cracks were present.
The determination of the blast protection level of laminated glass windows and facades is of crucial importance, and it is normally done by using experimental investigations. In recent years numericalmethods have becomemuch more powerful also with respect to this kind of application. This paper attempts to give a first idea of a possible standardization concerning such numerical simulations. Attention is drawn to the representation of the blast loading and to the proper description of the behaviour of the material of the mentioned products, to the geometrical meshing, and to the modelling of the connections of the glass components to the main structure.The need to validate the numerical models against reliable experimental data, some of which are indicated, is underlined.
During the past 20 years, innovative developments in concrete technology have enabled the production of ultra-high performance fibre reinforced concretes (UHPFC) for the protection and preservation of concrete structures. The main characteristics of UHPFC comprise high compressive and flexural strength as well as high ductility compared to normal strength, normal weight concrete (NSC). This paper focuses on the analysis of crack formation and crack propagation in UHPFC under tensile loading under quasistatic conditions by using acoustic emission (AE) and optical deformation analysis (ODA).
AE is a non-destructive technique to monitor the development of micro structural damage processes caused by external forces. In this context, AE allows for a continuous monitoring of changes in the microstructure (cracks) over time and the corresponding localisation by appropriate algorithms. The AE measurements were performed along with ODA at the surface of the samples in order to analyse the deformation behaviour of the samples and the crack propagation.
For the tests, a UHPFC reference mixture was developed and tested with three different volume percentages of steel fibres (1.0 V.-%, 2.0 V.-%, and 3.0 V.-%). This paper shows that the application of AE is a suitable method to analyse the crack propagation in UHPFC specimens under tensile loading and to localise the crack initiation. Furthermore, insights into the failure mechanism of the fibres are offered by the analysis of the signals of the AE measurements, which allows for a better understanding of UHPFC and its general performance.
Der durch Kräfte senkrecht zur Stabachse belastete Balken ist eines der Haupttragelemente des Stahlbetonbaus. Biegebalken finden unter anderem Anwendung in Form von Brückenträgern oder Unterzügen. Die bei maximaler Beanspruchung auftretenden Versagensformen unterteilen sich dabei in Biege- und Querkraftversagen (Schubversagen). Ein Versagen des Balkens kann je nach Versagensmechanismus mit oder ohne Vorankündigung erfolgen. Gebräuchliche Bemessungskonzepte der Baupraxis zur Dimensionierung entsprechender Tragelemente zielen auf ein Versagen mit ausreichender Vorankündigung (große Verformungen oder breite Risse) ab, wie es z.B. beim sekundären Biegedruckversagen entsteht. Für die Zustandsüberwachung von Bauwerken (z.B. Brücken) mittels zerstörungsfreier Prüftechniken sind fundierte Kenntnisse zu den bei Biegebeanspruchung auftretenden Schadensmechanismen erforderlich. Im Rahmen eines BAM-internen Projektes sollen durch praxisnahe Untersuchungen an einer brückenähnlichen Referenzstruktur unterschiedliche auf das Tragwerk einwirkende thermische und mechanische Belastungen untersucht werden und in die Entwicklung eines Monitoringsystems einfließen. Anhand der aus Biegeversuchen vorliegenden Ergebnisse wird der Einsatz unterschiedlicher Methoden der zerstörungsfreien Materialprüfung gezeigt und deren Anwendbarkeit für die Analyse des Verformungsverhaltens von Stahlbetonbalken diskutiert. Hierzu wurde das Verformungsverhalten eines Stahlbetonbalkens (L = 2,75 m) in einem Vierpunkt-Biegeversuch im Labormaßstab untersucht. Das Hauptaugenmerk liegt dabei auf der Charakterisierung der ausschlaggebenden Versagensmodi durch die einzelnen zerstörungsfreien Prüfverfahren und der Vergleich zu klassischen Messmethoden (z.B. Verformungsmessung mittels induktiver Wegaufnehmer (IWA)). Die Biegeversuche wurden dazu durch Schallemissionsanalyse (SEA) und optische Verformungsanalyse mittels Stereo-Fotogrammetrie (SF) und Bildkorrelationsverfahren (BKV) begleitet.
Current trend suggests that global energy consumption will increase in the future. This growing energy demand and advancement of technology lead to explore all potential offshore fossil and non-fossil energy sources, necessitating erection of exploration and production structures, rigs, platforms and towers, which are susceptible to adverse environmental conditions along with their maintenances. Cylindrical grouted joints provide suitable connections between steel substructure and foundation in these offshore platforms and wind structures especially monopiles for ease of installation. However, these are composite connections with exterior sleeve, interior pile and infill grout. The capacity of these connections is affected by number of factors. The literature over last four decades by numerous researchers has shown the development of these connections with increasingly higher capacities and influences on these capacities due to various factors. This paper provides a comprehensive review on the factors affecting the connection capacity along with technical challenges for the future. Critical aspects and shortcomings of the current connection systems and potential solutions may be sought after for these issues are also discussed.
The determination of the blast protection level of civil engineering buildings components
against explosive effects represents a topic of crucial importance, in current practice. However, some key aspects of blast resistant structures design have been only marginally considered in the last decade, and currently still require appropriate regulations. This is especially true in the case of windows and facades, where the intrinsic material brittleness is the major influencing parameter for blast-resistant assemblies. While blast assessment of buildings and systems is usually achieved by means of experimental investigations, as well as numerical simulations, general regulations and guidelines are currently missing.
In this regard, the European Reference Network for Critical Infrastructure Protection (ERNCIP) Thematic Group “Resistance of Structures to Explosion Effects” attempts to develop guidelines and recommendations aimed to harmonise test procedures in experimental testing of glass windows under blast, as well as standardized approaches for their vulnerability assessment via numerical modelling. In this paper, major Thematic Group outcomes and next challenges are briefly summarized.
The tensile behavior of strain-hardening cement-based composites (SHCC) is usually investigated on macroscopic scale by means of direct tension tests or bending tests. Additionally, the micromechanical properties of the composites are often described based on single fiber tension and pull-out tests. Such investigations, performed both on macroscopic and microscopic scales, are based on ‘classical’ force and displacement measuring techniques. Advanced test methods such as digital image correlation (DIC) and acoustic emission analysis (AE) may facilitate the identification and the analysis of the failure mechanisms in SHCC, which is important for both monitoring loaded SHCC elements and further material development and optimization. In this study, these two techniques are combined to characterize the failure mechanisms of three different types of SHCC in direct tension tests. The results are related to data of stress and strain measurements. It is shown that DIC provides detailed spatially resolved and stress related strain measurements. Furthermore, it is demonstrated that AE allows for the localization of active cracks, quantification of the damage accumulation under increasing stresses, and characterization of the dominant crack bridging mechanisms and failure modes observed in the different types of SHCC.
Alkali-activated slag materials are known for their high Chloride penetration resistance. This makes them potentially applicable as repair systems for damaged steel-reinforced concrete structures, which are exposed to chloride attack. For this purpose, the influence of the activator composition, i.e. the SiO2 and Na2O concentration of the alkaline solution on a) the compressive strength, b) shrinkage and mass change and c) the resistance against chloride penetration of four alkali-activated slag mortars (AASM) were studied. An ordinary Portland cement-based mortar was used as the reference sample. Increasing SiO2 and Na2O concentrations increased the strength, shrinkage and mass loss of the AASMs. The resistance of the mortars against chloride penetration was evaluated using the non-steady-state migration coefficient Dnssm obtained from NT BUILD 492. The results indicate that the Dnssm is related to differences in the pore solution of the AASMs rather than to differences in their microstructure. An upcoming study of the authors is going to evaluate this hypothesis by the accelerated chloride penetration (diffusion) test.
Die Grout-Verbindung stellt die Nahtstelle zwischen Gründungsbauwerk und aufgehender Tragstruktur sicher. Die Funktion und Dauerhaftigkeit dieser Verbindung ist essentiell für die sichere Betriebsphase von Offshore-Windenergieanlagen. Die Bemessung der Grout-Verbindung stellt aktuell weitgehendes Neuland ohne Langzeiterfahrung dar. Gleichzeitig sind die Bedingungen bei der Montage Offshore sehr schwierig und die eingesetzten Materialien sind aufgrund ihrer technischen Merkmale in Verbindung mit den Verarbeitungsbedingungen nicht unproblematisch. Demzufolge stellen Grout-Verbindungen ungeregelte Bauarten und die hierfür verwendeten Mörtel (Grouts) ungeregelte Bauprodukte dar. Im Rahmen der Genehmigung ist daher beim Bundesamt für Seeschifffahrt und Hydrographie (BSH) als zuständiger Genehmigungsbehörde für jedes Bauvorhaben eine projektbezogene Zustimmung im Einzelfall (ZiE) zu beantragen.
Vor diesem Hintergrund sollte im DIN-Arbeitsausschuss NA 005-51-07 AA "Windenergieanlagen" eine geschlossene Normenreihe für Tragstrukturen von Windenergieanlagen und Plattformen erarbeitet werden. Anhand der Normenreihe soll allen bei der Planung, Errichtung und dem Betrieb von Windkraftanlagen Beteiligten ein Regelwerk für Bemessung, Baustoffe und deren Verwendung zur Verfügung gestellt werden. Ein Verweis auf die Normenanforderungen bzgl. der stofflichen Anforderungen, Bemessung und Ausführung durch den betreffenden BSH-Standard ist möglich, da eine ZiE weiterhin notwendig ist. Jedoch kann der Genehmigungsprozess aufgrund der vereinheitlichten Randbedingungen vereinfacht werden. Nach der erfolgreichen nationalen Einführung der DIN 18088 soll die Harmonisierung auf europäischer Ebene erfolgen.
Ultra-high performance fiber-reinforced concretes (UHPFRCs) are most suitable for applications with extreme mechanical loads. These extreme conditions require ductile behavior under tensile loading, which is obtained solely by the working mechanism of steel fibers. Profound knowledge on the working mechanism of the steel fibers is necessary to optimize this material. Usually, this knowledge is obtained by means of classical destructive measuring techniques. Adopting measuring techniques from non-destructive material testing helps to analyze and to identify the different stages of the fracture mechanism of UHPFRC in detail. The application of different non-destructive measuring techniques is shown exemplary on tensile tests conducted on an UHPFRC mix and its applicability for analyzing the fracture behavior of such concretes is discussed. The main focus is on the characterization of the relevant failure modes under tensile loading by the different measuring techniques and the comparison with classical measuring techniques (e.g. extensometer). The tensile tests have been analyzed by optical deformation measurements using digital image correlation (DIC), acoustic emission analysis (AE), and 3D computed tomography (CT).
Ultra-high performance fiber-reinforced concretes (UHPFRCs) are most suitable for applications with extreme mechanical loads. These extreme conditions require ductile behavior under tensile loading, which is obtained solely by the working mechanism of steel fibers. Profound knowledge on the working mechanism of the steel fibers is necessary to optimize this material. Usually, this knowledge is obtained by means of classical destructive measuring techniques. Adopting measuring techniques from non-destructive material testing helps to analyze and to identify the different stages of the fracture mechanism of UHPFRC in detail. The application of different non-destructive measuring techniques is shown exemplary on tensile tests conducted on an UHPFRC mix and its applicability for analyzing the fracture behavior of such concretes is discussed. The main focus is on the characterization of the relevant failure modes under tensile loading by the different measuring techniques and the comparison with classical measuring techniques (e.g. extensometer). The tensile tests have been analyzed by optical deformation measurements using digital image correlation (DIC), acoustic emission analysis (AE), and 3D computed tomography (CT).
At present, Wind Turbine Generators (WTGs) operating in onshore and offshore wind farms are primary sources of renewable energy around the world. Cylindrical grouted sleeve connections are usually adopted in these WTG structures to connect the upper structure and foundation for ease of installation. These structures including grouted connections experience considerable adverse loading during their lifetimes. Settlements were reported inside similar connections used in energy structures especially oil and gas platforms, which were installed in last three decades. Thus, repair and rehabilitation of such connections in existing wind structures should also be planned ahead to keep them operating in the future. The nature of failure and crack generation in grouted connections are crucial prior to adopt a strengthening strategy. This pilot study is carried out to actualize the failure mechanism in the grouted connection, when subjected to axial loading. A novel reusable scaled cylindrical grouted connection with shear keys was designed and tested for its load bearing behaviour. The mechanical test was accompanied by classical measuring techniques (e.g. displacement transducer) as well as non-destructive measuring techniques (e.g. digital image correlation (DIC), acoustic emission analysis (AE)). The failure mechanism incorporating slippage of the shear keys and cracking of the grout was investigated. The capacity and applicability of such test mould were also discussed. The knowledge is expected to pave way towards repair of deteriorated grouted connections with similar geometry and failure pattern.
At present, Wind Turbine Generators (WTGs) operating in onshore and offshore wind farms are primary sources of renewable energy around the world. Cylindrical grouted sleeve connections are usually adopted in these WTG structures to connect the upper structure and foundation for ease of installation. These structures including grouted connections experience considerable adverse loading during their lifetimes. Settlements were reported inside similar connections used in energy structures especially oil and gas platforms, which were installed in last three decades. Thus, repair and rehabilitation of such connections in existing wind structures should also be planned ahead to keep them operating in the future. The nature of failure and crack generation in grouted connections are crucial prior to adopt a strengthening strategy. This pilot study is carried out to actualize the failure mechanism in the grouted connection, when subjected to axial loading. A novel reusable scaled cylindrical grouted connection with shear keys was designed and tested for its load bearing behaviour. The mechanical test was accompanied by classical measuring techniques (e.g. displacement transducer) as well as non-destructive measuring techniques (e.g. digital image correlation (DIC), acoustic emission analysis (AE)). The failure mechanism incorporating slippage of the shear keys and cracking of the grout was investigated. The capacity and applicability of such test mould were also discussed. The knowledge is expected to pave way towards repair of deteriorated grouted connections with similar geometry and failure pattern.
Alkali-activated slag materials are known for their high Chloride penetration resistance. This makes them potentially applicable as repair systems for damaged steel-reinforced concrete structures, which are exposed to chloride attack. For this purpose, the influence of the activator composition, i.e. the SiO2 and Na2O concentration of the alkaline solution on a) the compressive strength, b) shrinkage and mass change and c) the resistance against chloride penetration of four alkali-activated slag mortars (AASM) were studied. An ordinary Portland cement-based mortar was used as the reference sample. Increasing SiO2 and Na2O concentrations increased the strength, shrinkage and mass loss of the AASMs. The resistance of the mortars against chloride penetration was evaluated using the non-steady-state migration coefficient Dnssm obtained from NT BUILD 492. The results indicate that the Dnssm is related to differences in the pore solution of the AASMs rather than to differences in their microstructure. An upcoming study of the authors is going to evaluate this hypothesis by the accelerated chloride penetration (diffusion) test.
Remediation of Cracks Formed in Grouted Connections of Offshore Energy Structures under Static Loads
(2018)
The future energy demand necessitates the exploration of all potential energy sources both onshore and offshore. Global trend has shifted towards offshore energy, which can be obtained from either carbon intensive or renewable options, hence requiring structures such as rigs, platforms, and monopiles. Most of these structures adopt easily installable construction techniques, where lower foundation need to be connected with the super structure by mean of grouted composite joints. Generally, these composite connections have exterior sleeve, interior pile and infill grout. Being located in remote offshore conditions, connections can experience considerable adverse loading during their lifetimes. Degradations were reported inside similar connections, which were installed in last three decades. Besides, grouting in the offshore sites may often be proven difficult, which eventually leads to reduced capacity of connections in the long run. Thus, repair and rehabilitation of such connections should be planned ahead to minimize operational delays and costs in the future. This study aims at characterizing the nature of crack generation in grouted connections and thereby identifying the potential of repair using suitable repair material. Scaled grouted joints were manufactured using a novel mold, and connections were loaded under static load to visualize the main failure pattern. The failure mechanism and loading capacity are found compatible to previous results from earlier literature. Grouted connection was then repaired using cementitious injectable grout. The effectiveness of the repair system is also discussed.
Repair is an indispensable part of the maintenance of structures over their lifetimes. Structural grouting is a widely used remediation technique for concrete components, trenches, mine subsidence, dam joints, restoration of masonry structures, and geological stabilizations. A structural grout system should be injectable in narrow spaces and hence include ingredients with finer particles. Ultrafine cements are ideal for these type of demanding grouts due to their superior properties compared to that of the less expensive, but coarser ordinary Portland cement (OPC). Supplementary cementitious materials (SCMs) are often used to replace OPC clinker based binder in order to modify certain properties and to reduce costs. The most commonly used SCMs are fly ash (FA), and ground granulated blast furnace slag (GGBS). For various special applications microsilica (MS), and metakaolin (MK) are also used. Identifying the optimum replacement contents of OPC by SCMs are a challenge during the design of such grouts. The aim of this experimental study is to investigate the effect of the selected SCMs (FA, MS and MK) on the slump flow, time of efflux, viscosity, shrinkage, and compressive and flexural strength of ultrafine cement based grouts with constant water-binder ratio and superplasticizer content. The test program was formulated using Box-Behnken design principles. Maximum percentages of replacement with ultrafine cement was 6% by volume of cement for MS and 16% for FA, and MK. The results suggest that most investigated grouts have the potential to be used for structural applications. The appropriate quadratic models are then formulated through statistical tools and presented as response surfaces. The trends indicate that fly ash improves the rheological properties, whereas microsilica and metakaolin positively affect shrinkage and mechanical properties to some extent. Based on the influence of SCMs and priorities among the properties, Decision Matrix Analysis (DMA) is carried out to select the most suitable ones among the SCMs. The analysis suggests that microsilica and fly ash are more suitable as SCMs than metakaolin without affecting the properties.
The authors are currently investigating the possibility to apply compaction grouting for offshore pile foundations (Jacket piles as well as monopiles) as a possible retrofitting technique for an optimised foundation concept. In this research project, we are developing a design approach aiming to predict the ideal amount and properties of a grout for a specific soil situation and desired improvement of pile bearing capacity after Installation and during service time. Both numerical and experimental tests have been carried out to investigate the injection process during which a highly viscous grout is injected into the soil under high pressure to displace and compact the surrounding soil without fracturing it. The implicit Material Point Method (MPM) based on a mixed formulation is the numerical technique chosen to deal with the expected large deformations and the arbitrary shape of the developing grout bulb. The usage of MPM prevents both the need of remeshing and the numerical instability induced by extensive mesh distortion. For validation with experimental results, we have constructed a testing chamber with one transparent sidewall. This chamber enables us to observe the injection process directly at the transparent vertical window and to measure the in-plane soil displacements and strains by means of the Digital Image Correlation (DIC) technique.
The results already reveal the interrelation of soil and grout properties for a successful usage of this common ground improvement technique.
Grouting is a universal repair and strengthening technique, which is constantly used for structural remediation of concrete components, trenches, mine subsidence, dam joints, restoration of masonry structures, and geological stabilizations. Having an extremely small particle size of only few microns, ultrafine cements are ideal for grouting applications due to their superior permeability and compressive strength properties of the hardened cement paste compared to that of the less-expensive, but coarser ordinary Portland cements. Supplementary cementitious materials (SCMs) are often used to replace ultrafine cement in order to modify certain properties and to reduce costs. The aim of this experimental study is to investigate the effect of three supplementary materials: microsilica (MS), fly ash (FA), and metakaolin (MK) on the workability, and mechanical properties of an ultrafine cement based grout with a constant water-binder ratio and constant superplasticizer content. Maximum percentages of replacement with ultrafine cement were 6% by volume of cement for MS and 16% for FA, and MK. In general, results suggest that the workability is improved by addition of FA, whereas is reduced, when modified with MS and MK. The compressive strength of grout after cement replacement remains comparable to that of pure cement grout. However, there is a tendency of the MS to positively affect the compressive strength opposite to FA, whereas flexural strength is positively affected by FA. Based on the results, it is evident that grouts with Hägerman cone flow more than 500 mm and compressive strength of more than 90 MPa after 28 days can be produced.
Grouts are particularly favoured in rehabilitation of structures due to penetrability and convenience of application. Grouts for repair applications typically require high-performance properties such as rapid strength development and superior shrinkage characteristics. Sometimes industrial by-products referred as supplementary cementitious materials (SCM) are used with neat cement due to their capabilities to provide binding properties at delayed stage. Micro silica, fly ash and metakaolin are such SCMs, those can modify and improve properties of cement products. This study aims at investigating long-term mass loss and linear shrinkage along with long-term compressive and flexural strength for grouts produced from ultrafine cement and SCMs. A series of mixtures were formulated to observe the effect of SCMs on these grout properties. Properties were determined after 365 days of curing at 23 °C and 55% relative humidity. The effect of SCMs on the properties are characterised by statistical models. Response surfaces were constructed to quantify these properties in relation to SCMs replacement. The results suggested that shrinkage was reduced by metakaolin, while micro silica and fly ash had positive effects on compressive and flexural strength, respectively.
Superplasticizer and Shrinkage Reducing Admixture Dosages for Microfine Cement in Grout Systems
(2019)
Grouts have numerous applications including crack repair as maintenance in construction industries. Microfine cements are intensively used for high strength mortar and grout products. They are ideal for injection grouting in structural repair. Such grouts should have suitable rheological properties to be injectable, especially those used in repair and rehabilitation. The use of superplasticizers (SP) in these products is thus becoming increasingly crucial to achieve favorable workability and viscosity properties. A difficulty in such grouts is the plastic shrinkage due to finer particles used. It is thus necessary to determine optimum SP and shrinkage reducing admixture (SRA) dosages for a microfine cement based grout. In this study, a saturation dosage was decided from two Polycarboxylate ether (PCE) based SPs in relation to neat cement using slump flow and rheological parameters. A range of grout mixtures was formulated containing micro silica (MS) and fly ash (FA), and tested for suitable rheological and mechanical parameters. Based on the results, a grout mixture with MS and FA was selected to determine optimum SRA content. According to the results, a SP dosage of 3% by weight of neat cement is sufficient to achieve saturation. The grout material including MS and FA can produce comparable properties to neat cement grout. MS is found to improve compressive strength within the range considered, whereas a higher FA content provides favourable rheological properties. Finally, a SRA dosage of 4%, which could reduce the shrinkage by about 43% after 28d days, is determined for the grout system.
Grouts have numerous applications in construction industry such as joint sealing, structural repair, and connections in precast elements. They are particularly favoured in rehabilitation of structures due to penetrability and convenience of application. Grouts for repair applications typically require high-performance properties such as rapid strength development and superior shrinkage characteristics. Sometimes industrial by-products referred as supplementary cementitious materials (SCM) are used with neat cement due to their capabilities to provide binding properties at delayed stage. Micro silica, fly ash and metakaolin are such SCMs, those can modify and improve properties of cement products. This study aims at investigating long-term mass loss and linear shrinkage along with long-term compressive and flexural strength for grouts produced from ultrafine cement and SCMs. A series of mixtures were formulated to observe the effect of SCMs on these grout properties. Properties were determined after 365 days of curing at 23oC and 55% relative humidity. The effect of SCMs on the properties are characterised by statistical models. Response surfaces were constructed to quantify these properties in relation to SCMs replacement. The results suggested that shrinkage was reduced by metakaolin, while micro silica and fly ash had positive effects on compressive and flexural strength, respectively.
Global energy consumption will increase in the future necessitating both fossil fuels and renewable energy choices - especially wind energy. Such high energy demand requires installation of offshore energy structures, rigs, platforms and towers, which are susceptible to adverse environmental conditions along with maintenances. Due to their large size and remote locations, cylindrical grouted joints are often adopted between substructure and foundation in these offshore platforms and wind structures such as monopiles. However, these connections are composite structures with exterior sleeve, interior pile and infill mortar. Degradation and settlements were reported inside similar connections, which were installed in last three decades. Besides, grouting in the offshore sites were proven difficult to obtain ideal load bearing capacity. In-situ loading conditions were also found to be affecting the failure mechanism inside such connections. This study aims at characterizing the nature of cracks generated in these grouted connections under both static and cyclic loading. Scaled grouted joints were manufactured using a novel reusable mold, and connections were loaded to failure to visualize the main failure patterns. An assessment between failure under these two types of load is drawn along with comparison to previously available literature.
Global energy consumption will increase in the future necessitating both fossil fuels and renewable energy choices - especially wind energy. Such high energy demand requires installation of offshore energy structures, rigs, platforms and towers, which are susceptible to adverse environmental conditions along with maintenances. Due to their large size and remote locations, cylindrical grouted joints are often adopted between substructure and foundation in these offshore platforms and wind structures such as monopiles. However, these connections are composite structures with exterior sleeve, interior pile and infill mortar. Degradation and settlements were reported inside similar connections, which were installed in last three decades. Besides, grouting in the offshore sites were proven difficult to obtain ideal load bearing capacity. In-situ loading conditions were also found to be affecting the failure mechanism inside such connections. This study aims at characterizing the nature of cracks generated in these grouted connections under both static and cyclic loading. Scaled grouted joints were manufactured using a novel reusable mold, and connections were loaded to failure to visualize the main failure patterns. An assessment between failure under these two types of load is drawn along with comparison to previously available literature.
The aim of an ongoing research project is to develop a design approach for typical offshore driven piles (e.g. Jacket piles) based on the application of injections by compaction grouting directly at the pile shaft. The paper aims to present the results of laboratory and in-situ tests, which reveal the efficiency and the promising potential of the optimised foundation concept for a more economic dimensioning of pile foundations and to increase their bearing capacity in non-cohesive soil at any moment after installation.