Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (31)
- Zeitschriftenartikel (15)
- Vortrag (12)
- Forschungsbericht (6)
- Beitrag zu einem Sammelband (1)
Schlagworte
- Acoustic emission analysis (6)
- Cracks (5)
- Durability (5)
- Digital image correlation (4)
- Grout (4)
- Grouted connection (4)
- Nano-silica (4)
- Spaltzugfestigkeit (4)
- Tensile strength (4)
- Concrete (3)
- Crack formation (3)
- Fly ash (3)
- Metakaolin (3)
- Optische Verformungsanalyse (3)
- Repair (3)
- Ringversuch (3)
- Schallemission (3)
- Shrinkage (3)
- Stahlbeton (3)
- Strength (3)
- accident prevention (3)
- building industry (3)
- explosive (3)
- glass industry (3)
- industrial infrastructure (3)
- research report (3)
- technical standard (3)
- urban infrastructure (3)
- 3D computed tomography (2)
- Accident prevention (2)
- Alkali-activated materials (2)
- Alkali-activated slag mortar (2)
- Bending (2)
- Bingham fluid (2)
- Box-Behnken (2)
- Building industry (2)
- Carbonation (2)
- Chloride (2)
- Chloride migration coefficient (2)
- Crack pattern (2)
- Cyclic load (2)
- Explosive (2)
- Failure (2)
- Fibre pull-out (2)
- Freeze-thaw (2)
- Grouted connections (2)
- Grouting (2)
- Industrial infrastructure (2)
- Long-term shrinkage (2)
- Micro silica (2)
- Offshore (2)
- Optical deformation measurement (2)
- Rehabilitation (2)
- Research report (2)
- Risk prevention (2)
- Rissbildung (2)
- Self compacting concrete (2)
- Static load (2)
- Steel fibres (2)
- Stereophotogrammetry (2)
- Strengthening strategy (2)
- Technical standard (2)
- Terrorism (2)
- Tragverhalten bei Biegebeanspruchung (2)
- UHPFRC (2)
- Urban infrastructure (2)
- Verfahrenspräzision (2)
- risk prevention (2)
- safety standard (2)
- terrorism (2)
- 3DCP (1)
- Acoustic Emission Analysis (1)
- Acoustic emission (1)
- Additive manufacturing (1)
- Additive manufacturing of concrete (1)
- Analysis of variance (1)
- Architectural use (1)
- Arena test (1)
- Baustoffe (1)
- Betondickglasfenster (1)
- Betonfahrbahndecke (1)
- Betonfahrbahndecken (1)
- Blast experiment (1)
- Blast loaded glass windows (1)
- Blast loads (1)
- Blast protection (1)
- Blast-load (1)
- Bruchmechanismus (1)
- Building materials (1)
- Cathodic corrosion protection (1)
- Cementitious composites (1)
- Chloride and Freeze-thaw (1)
- Chloride and freeze-thaw (1)
- Chloride penetration (1)
- Compaction Grouting (1)
- Compaction behavior (1)
- Compaction behavior (A) (1)
- Compaction grouting (1)
- Computertomografie (1)
- Conception and design (1)
- Concrete Beam (1)
- Concrete beam (1)
- Concrete printing (1)
- Concrete repair (1)
- Concrete-glass windows (1)
- Concrete-glazing (1)
- Crack propagation (1)
- Crash-material (1)
- Crashkörper (1)
- Crashmaterial (1)
- Critical infrastructure (1)
- DAS (1)
- DIN 18088-5 (1)
- Dalle-de-verre (1)
- Dalles de verres (1)
- Debonding Mechanism (1)
- Decision matrix analysis (1)
- Design (1)
- Digital Image Correlation (1)
- Digital Image Correlation (DIC) (1)
- Distributed acoustic sensing (1)
- Distributed fibre optic sensor (1)
- Drop tower (1)
- Electrochemical realkalisation (1)
- Elektrochemische Realkalisierung (1)
- Embedded fiber optic sensor (1)
- Energiedissipation (1)
- Energy (1)
- Energy dissipation (1)
- Entwurf und Konstruktion (1)
- Experimental testing (1)
- Explosion effects (1)
- Explosionsbeanspruchung (1)
- Explosionswirkung (1)
- Explosivstoff (1)
- Facades (1)
- Faseroptische Sensorik (1)
- Fassade (1)
- Fassadenverankerung (1)
- Façade connector (1)
- Fiber reinforcement (1)
- Fibre bragg grating (1)
- Fibre optic sensors (1)
- Finite element numerical modelling (1)
- Glass industry (1)
- Glazing windows (1)
- Green-strength (1)
- Green-strength (C) (1)
- Grout-Verbindung (1)
- Grouted Connection (1)
- Hard impact (1)
- Heritage (1)
- Historic building (1)
- Injection Sequence (1)
- Innovative Prüftechniken (1)
- Instandsetzung (1)
- Intensive compaction test (1)
- Intensive compaction test (C) (1)
- Joint capacity (1)
- Kaiser-Wilhelm-Gedächtniskirche (1)
- Lightweight concrete (1)
- Maintenance (1)
- Material Point Method (MPM) (1)
- Material behavior (1)
- Materialkennlinie (1)
- Microfine Cement (1)
- Microsilica (1)
- Mix design (1)
- Mixed formulation (1)
- Monitoring (1)
- Mortar (E) (1)
- Multiple cracking (1)
- Multiple impact (1)
- Nano silica (D) (1)
- Nano-SiO2 (1)
- Nano-silica sludge (D) (1)
- Non-Destructive Testing (1)
- Non-destructive testing (1)
- Offshore Pile Foundation (1)
- Offshore pile foundation (1)
- Offshore wind energy (1)
- Offshore-Windenergieanlagen (1)
- Optical deformation analysis (1)
- Particle size distribution (B) (1)
- Passivation (1)
- Polymer Fibres (1)
- Polymers (1)
- Pozzolanic index (C) (1)
- Process monitoring (1)
- Präzision (1)
- Prüfverfahren AL Sp-Beton (1)
- Pull-Out Behaviour (1)
- RDO - Beton (1)
- Reinforced concrete beam (1)
- Repair mortar (1)
- Restoration (1)
- Rheology (1)
- Safety standard (1)
- Schalenbildung (1)
- Self Compacting (1)
- Self compacting (1)
- Shear keys (1)
- Shock tube (1)
- Shrinkage Reducing Admixture (1)
- Simulation (1)
- Soft impact (1)
- Stahlfaserbeton (1)
- Standardisation (1)
- Standardization (1)
- Static loading (1)
- Strain-hardening (1)
- Structural response (1)
- Superplasticizer (1)
- Supplementary Cementitious Materials (1)
- Supplementary cementitious materials (1)
- Supplementary cementitious materials (D) (1)
- Surface area (B) (1)
- Tensile Capacity (1)
- Tensile loading (1)
- Tension (1)
- Tuffstein (1)
- UHPFC (1)
- Ultrasonic waves (1)
- Vergleich- und Wiederholbedingungen (1)
- Viscosity (1)
- Water demand (A) (1)
- Workability (1)
- Workability (A) (1)
- Zero-slump concrete (1)
- Zero-slump concrete (A) (1)
- Zugbeanspruchung (1)
- simulation (1)
- бетон (1)
- зaморозок (1)
- метод испытания (1)
Organisationseinheit der BAM
- 7 Bauwerkssicherheit (26)
- 7.4 Baustofftechnologie (24)
- 7.2 Ingenieurbau (12)
- 7.1 Baustoffe (8)
- 8 Zerstörungsfreie Prüfung (7)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (4)
- 8.6 Faseroptische Sensorik (4)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (3)
- 2 Prozess- und Anlagensicherheit (2)
- 2.4 Prüfung und Bewertung von Explosivstoffen/Pyrotechnik (2)
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (12)
This paper presents experimental investigations and analyses on the early-age-behavior of zero-slump concrete, such as compaction behavior and green-strength. First, the influence of the granulometric properties of the fines is discussed in detail. For this purpose, the early-age behavior of two different fines (quartz flour and fly ash) is investigated by means of the intensive compaction test (IC-test). The tests on the influence of the fines focus on effects caused by differences in the particle shape and the use of a plasticizing admixture. The conducted tests on the compaction behavior of the fines and their corresponding green-strength are extended to continuously graded granular mixes. Here, the influence of optimized particle packing on the early-age behavior is presented and a comparison on the basis of the aforementioned quartz flour and fly ash is made. In this consideration, experimental investigations on the early-age behavior of a zero-slump concrete mix and possible effects on the hardened concrete properties are included.
This paper addresses the characterization of six different amorphous silica samples with respect to their application in cement paste. Different mixes are compared and analyzed using the mini spread-flow test. Also the granular properties, different void fraction states of packing and distribution moduli q are analyzed and compared using a mix design tool. A deformation coefficient is derived from the spread-flow test, which correlates with the value of specific surface area computed from the particle size distribution, and intrinsic density of the samples. Finally, the thickness of a constant water layer of 25 nm around the particles is computed at the onset of flowing. The granular analysis demonstrated that it is possible to decrease the water demand of the cement paste when nanoparticles are added and the resulting grading follows the modified Andreasen and Andersen curve (q = 0.5), and the concentration of nano silica is less than 5% bwoc.
Für die rechnerische Dimensionierung der Betondecken im Oberbau von Verkehrsflächen für den Neubau sowie die Erneuerung nach RDO-Beton 09 ist die statische Spaltzugfestigkeit an der unteren und oberen Bohrkernscheibe entsprechend der Vorgaben der AL Sp-Beton zu bestimmen. Aufgrund der unzureichenden Kenntnis der Präzision dieses Prüfverfahrens wurden, basierend auf dem Entwurf des FGSV-Merkblatts zur statistischen Auswertung von Prüfergebnissen, mit einem breit aufgestellten Ringversuch die statistischen Kennwerte an Labor- und Bestandsbetonen unter Vergleich- und Wiederholbedingungen ermittelt. Zur möglichst guten statistischen Absicherung nahmen an dem Ringversuch dreizehn erfahrene Prüfstellen teil, die vorab einem Audit unterzogen wurden. Zur Abdeckung des vielschichtigen Einsatzes des Prüfverfahrens erfolgte der Ringversuch an acht Prüflosen, die sowohl die Erst-/ Eignungsprüfung und Übereinstimmungskontrolle bei Neubaumaßnahmen, als auch die Restsubstanzbewertung von Betonfahrbahnplatten berücksichtigen. Zur Bewertung des Materialeinflusses wurde zusätzlich ein Prüflos mit Labormörtel untersucht.
Die Probenvorbereitung erfolgte zentral an der BAM. Zur Sicherstellung einheitlicher Prüfbedingungen bei den Prüfstellen wurde zusätzlich eine detaillierte Standardarbeitsanweisung erarbeitet, die partiell bereits Eingang in das Normenwerk gefunden hat. Bei der Plausibilitätsprüfung aller prüflosspezifischen Einzelwerte der Spaltzug- und Druckfestigkeit wurden vereinzelt sowohl Ausführungsfehler als auch Übertragungs- und Tippfehler festgestellt. Der sich anschließende Lilliefors-Test zeigt, dass die ermittelten Einzelwerte bis auf wenige Aus-nahmen normalverteilt sind und damit die Voraussetzungen für die statistische Auswertung gegeben sind.
Mittels grafischer Darstellung der Mandel’s h- und k-Werte wurden die Auffälligkeiten hinsichtlich der Mittelwerte und Varianzen prüflosspezifisch für die einzelnen Prüfstellen visualisiert und anschließend einige von ihnen mittels Grubbs- und Cochran-Test als Ausreißer identifiziert. Nach Ausreißerelimination wurde mit dem klassischen Verfahren bei der Spaltzugfestigkeit der geringste Variationskoeffizient unter Vergleich- und Wiederholbedingungen bei der Erst-/Eignungsprüfung mit 6,2 und 6,4 Prozent ermittelt. Bei einer Verminderung des Materialeinflusses durch die Verwendung eines Labormörtels verbessern sich die statistischen Kennwerte auf 4,5 und 5,3 Prozent. Mit 8,2 und 9,5 Prozent beziehungsweise 8,6 und 9,5 Prozent werden bei der Restsubstanzbewertung von Wasch- und Unterbetonen die höchsten Werte bestimmt.
Das robuste Auswerteverfahren (ohne Eliminierung der Ausreißer) nach dem Entwurf des FGSV-Merkblatts zur statistischen Auswertung von Prüfergebnissen erwies sich in der Form als ungeeignet und bedurfte einer Überarbeitung. Bezüglich der vergleichend mit klassischen und robusten Verfahren gewonnenen Kennwerte ist festzustellen, dass bei sehr homogenen Messergebnissen eines Prüfloses beide Verfahren nahezu die gleichen statistischen Kennwerte liefern. Bei der Eliminierung von Ausreißern sind die Ergebnisse des robusten Verfahrens in der Regel etwas größer als die des klassischen Verfahrens.
Die begleitenden vertiefenden Untersuchungen bei der Spaltzugprüfung mit innovativen Prüftechniken lieferten wertvolle Erkenntnisse zur Bewertung der Prüfeinflüsse.
The bond between polymer fibers and the surrounding cementitious matrix is essential for the development of concrete reinforcement. The single fiber pull-out test (SFPT) is the standard characterization technique for testing the bond strength. However, the different phases of debonding cannot be distinguished by the SFPT. This study investigates the debonding of different polymer fibers from the surrounding cementitious matrix with a modified SFPT and proposes methods to change the SFPT setup to generate more valuable information on the debonding mechanism. The SFPT was equipped with linear variable differential transformers (LVDT), digital image correlation (DIC) and acoustic emission (AE) analysis. The results demonstrate that the modified SFPT allows a better understanding of the different phases of debonding during fiber pull-out. Furthermore, bond strength values calculated by different methods reveal that the chemical bond of the investigated polymers is not different as reported by previous studies. Deformation measurements performed using LVDTs and DIC are suitable measuring techniques to characterize the debonding mechanism in SFPT. A correlation between recorded AE and debonding phases was not found.
Zur Bewertung der Widerstandsfähigkeit von Schutzobjekten und Bauteilen gegen Explosionsbeanspruchung führt die Bundesanstalt für Materialforschung und -prüfung (BAM) regelmäßig Sprengversuche im Realmaßstab auf einem Testgelände durch.
Solche Versuche sind planungs- und ressourcenintensiv, sodass sie zunehmend durch numerische Simulationen ergänzt bzw. ersetzt werden.
Aktuelle Forschungsarbeiten zielen darauf ab, neue Berechnungsmethoden und Materialmodelle zu entwickeln, mit denen die Bestimmung der Bauteilantwort sowie die daraus resultierende Schädigung nach einem Explosionsereignis möglich sind.
Zur Validierung solcher Ansätze ist es notwendig, systematische Versuche mit unterschiedlichen Szenarien durchzuführen, bei denen die relevanten Parameter mit Hilfe verschiedener Messmethoden aufgezeichnet werden.
Alkali-activated slag materials are known for their high Chloride penetration resistance. This makes them potentially applicable as repair systems for damaged steel-reinforced concrete structures, which are exposed to chloride attack. For this purpose, the influence of the activator composition, i.e. the SiO2 and Na2O concentration of the alkaline solution on a) the compressive strength, b) shrinkage and mass change and c) the resistance against chloride penetration of four alkali-activated slag mortars (AASM) were studied. An ordinary Portland cement-based mortar was used as the reference sample. Increasing SiO2 and Na2O concentrations increased the strength, shrinkage and mass loss of the AASMs. The resistance of the mortars against chloride penetration was evaluated using the non-steady-state migration coefficient Dnssm obtained from NT BUILD 492. The results indicate that the Dnssm is related to differences in the pore solution of the AASMs rather than to differences in their microstructure. An upcoming study of the authors is going to evaluate this hypothesis by the accelerated chloride penetration (diffusion) test.